Mounting The Subscriber Unit To A Pole - Siemens RUGGEDCOM WIN5214 Installation Manual

Hide thumbs Also See for RUGGEDCOM WIN5214:
Table of Contents

Advertisement

Chapter 2
Installing the Subscriber Unit
If the subscriber unit is not synchronized with the base station, make sure the subscriber unit is properly
configured. For more information, refer to the RUGGEDCOM WIN User Guide for the RUGGEDCOM WIN5214.
If the expected link quality still cannot be achieved, try to improve the reception quality by placing the
subscriber unit at a higher point or in an alternate location.
12. Make sure the subscriber unit is properly grounded according to local standards. For more information, refer
to
Section 2.6, "Grounding the Subscriber
13. Tighten the screws connecting the arm bracket to the subscriber unit and mounting bracket. Make sure the
screws are torqued to 24 N·m (17.7 ft. lb.).
Section 2.5.2

Mounting the Subscriber Unit to a Pole

The subscriber unit can be attached to any pipe or pole with a diameter of 44.5 to 254 mm (1.75 to 10 in).
To mount the subscriber unit to a pole, do the following:
1.
Attach the subscriber unit to the mounting bracket.
Figure 4: Mounting the Subscriber Unit to a Large Pole
1. Subscriber Unit    2. Pole    3. Clamping Bracket    4. Mounting Bracket    5. M8-25 Hex Screw    6. M8 Spring Washer    7. M8 Flat
Washer    8. M8 Nut    9. M8-70 Hex Screw
12
Unit".
4
3
5
6
7
RUGGEDCOM WIN5214
Installation Guide
6
7
6
9
8
Mounting the Subscriber Unit to a Pole
1
2
3

Advertisement