14 FLEX Ex 85...253V AC In/Quad-Ex DC Out Power Supply
Table 2 Environmental Specifications
Attribute
Temperature, operating
Temperature, storage
Relative humidity
Shock
Operating
Nonoperating
Vibration
Emissions
Table 3 Certifications
Certifications
(when
(1)
product is marked)
C-Tick
INMETRO
(1)
See the Product Certification link at www.ab.com for Declarations of Conformity, Certificates, and other
certification details.
Publication
1797-IN533-EN-P - August 2017
Value
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
-20...70 °C (-4...158 °F)
IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),
IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat)
-40...85 °C (-40...185 °F)
IEC 60068-2-30 (Test Db, Unpackaged Nonoperating Damp
Heat):
5...95% noncondensing
IEC60068-2-27 (Test Ea, Unpackaged shock):
15 g
15 g
IEC60068-2-6 (Test Fc, Operating):
2 g @ 10...500 Hz
CISPR 11
Radiated, Class A
Conducted, Class B
Value
Australian Radiocommunications Act, compliant with:
AS/NZS CISPR11; Industrial Emissions
BR-Ex de [ib] IIC T4
Certificate number 05/UL-BRAE-0018X