Resetting The Device To Factory Default - Bosch APC‑AMC2‑4WCF Installation Manual

Access modular controller 2
Hide thumbs Also See for APC‑AMC2‑4WCF:
Table of Contents

Advertisement

Access Modular Controller 2
5.3.2

Resetting the Device to Factory Default

1.
2.
3.
4.
5.
The AMC2-4W now has the following network configuration:
Figure 5.3: Resetting the AMC2 to delivery state
Bosch Security Systems B.V.
Reset the AMC2-4W as described above.
Open the upper case of the AMC2-4W as described in Opening the Case, page 15.
Set all six DIL switches of the RS-485 selector to ON as shown in the figure below.
Press the reset button on the the board.
Set the DIL switches back in the address state before resetting.
DHCP = 1
IP = [assigned by DHCP server or "0.0.0.0" if not available]
Subnet mask = [assigned by DHCP server or "0.0.0.0" if not available]
Password = no password
Installation manual
Operating | en
39
2020-01 | V02 |