Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch.
We recommend careful consideration be given to the effects of
elevated mantel temperatures which may be in excess of product
design, for example: candles, plastic or pictures. This can cause
melting, deformation, discoloration or premature failure of T.V. and
radio components.
Side wall clearances are 6". Combustible surrounds may be installed
with 6" clearance to the side of the fireplace as shown in Figure 10.d
Drywall Sheetrock
15 1/2" Non-Combustible
15 ½" Non-Combustible
Facing Material
Facing Material
Non-Combustible
Non-combustible Header
Header
Figure 10.d Combustible surrounds.
22
Drywall Sheetrock
15½"
6"
Installation
XG0231 - 061120