CAUTION
New refrigerant air conditioner installation
• This air conditioner adopts the new HFC refrigerant (R410A)
which does not destroy ozone layer.
• The characteristics of R410A refrigerant are; easy to absorb
water, oxidizing membrane or oil, and its pressure is approx. 1.6
times higher than that of refrigerant R22. Accompanied with the
new refrigerant, refrigerating oil has also been changed.
Therefore, during installation work, be sure that water, dust,
former refrigerant, or refrigerating oil does not enter the
refrigerating cycle.
• To prevent charging an incorrect refrigerant and refrigerating
oil, the sizes of connecting sections of charging port of the
main unit and installation tools are changed from those for the
conventional refrigerant.
• Accordingly the exclusive tools are required for the new
refrigerant (R410A).
• For connecting pipes, use new and clean piping designed for
R410A, and please care so that water or dust does not enter.
To Disconnect the Appliance from Main Power Supply.
• This appliance must be connected to the main power supply by
means of a switch with a contact separation of at least 3 mm.
The installation fuse (all type can be used) must be used for
the power supply line of this conditioner.
Do not wash air conditioners with pressure washers.
• Electric leaks may cause electric shocks or fires.
13-EN
1117701001-EN.indd 7
1117701001-EN.indd 7
– 7 –
14-EN
2/26/2559 BE 11:48 AM
2/26/2559 BE 11:48 AM