Selection of pipe size
No.
Title
Use part
Type
MMY-MAP0806*
Outdoor unit
MMY-MAP1006*
Ô
Outdoor unit
(1)
Outdoor unit
MMY-MAP1206*
connecting pipe
connection
MMY-MAP1406*
piping kit
MMY-MAP1606*
MMY-MAP1806*
MMY-MAP2006*
Total capacity codes of outdoor units at the
Outdoor unit
Between
connection
Equivalent to capacity
Outdoor unit
piping kit
(2)
connection
Ô
45.0 to below 61.5
piping
Outdoor unit
61.5 to below 73.0
*6
connection
73.0 to below 101.0
piping kit
101.0 or more
Total capacity codes of all
Equivalent to
capacity
Outdoor unit
connection piping
22.4 to below 33.5
kit of header unit
(3)
Main piping
33.5 to below 38.4
Ô
38.4 to below 45.0
First branching
section
45.0 to below 61.5
61.5 to below 73.0
73.0 to below 101.0
101.0 or more
Total capacity codes of indoor
Branching section
units at the downstream side
Ô
Equivalent to
Branching section
capacity
Below 18
Branching section
Branching pipe
(4)
Ô
18 to below 34
*1, *2, *6
Flow Selector unit
34 to below 45.5
45.5 to below 56.5
Flow Selector unit
56.5 to below 70.5
Ô
70.5 to below 98.5
Branching section
98.5 or more
Capacity rank
Flow Selector unit
Indoor unit
(5)
Ô
connecting pipe
Indoor unit
131-EN
1117701001-EN.indd 66
1117701001-EN.indd 66
Selection of pipe size
Balance pipe
Suction gas
Discharge
side
side
gas side
Ø9.5
Ø22.2
Ø19.1
Ø9.5
Ø22.2
Ø19.1
Ø9.5
Ø28.6
Ø19.1
Ø9.5
Ø28.6
Ø22.2
Ø9.5
Ø28.6
Ø22.2
Ø9.5
Ø28.6
Ø22.2
Ø9.5
Ø28.6
Ø22.2
Suction
Discharge
downstream side
gas side
gas side
Equivalent to HP
16 to below 22
Ø28.6
Ø22.2
22 to below 26
Ø34.9
Ø28.6
26 to below 36
Ø34.9
Ø28.6
36 or more
Ø41.3
Ø28.6
Suction
outdoor units
Discharge
Liquid
gas
gas side
side
side
Equivalent to HP
Pipe size differs
8 to below 12
Ø22.2
Ø19.1
Ø12.7
based on the total
12 to below 14
Ø28.6
Ø19.1
Ø12.7
capacity codes of
all outdoor units
14 to below 16
Ø28.6
Ø22.2
Ø15.9
(See Table 2.)
16 to below 22
Ø28.6
Ø22.2
Ø19.1
22 to below 26
Ø34.9
Ø28.6
Ø19.1
26 to below 36
Ø34.9
Ø28.6
Ø22.2
36 or more
Ø41.3
Ø34.9
Ø22.2
Suction
Discharge
Liquid
gas
gas side
side
Pipe size differs
side
Equivalent to HP
based on the total
capacity code
Below 6.4
Ø15.9
Ø12.7
Ø9.5
value of indoor
6.4 to below 12.2
Ø22.2
Ø19.1
Ø12.7
units at the
12.2 to below 16.2
Ø28.6
Ø22.2
Ø15.9
downstream side.
16.2 to below 20.2
Ø28.6
Ø22.2
Ø19.1
(See Table 1
and 2.)
20.2 to below 25.2
Ø34.9
Ø28.6
Ø19.1
25.2 to below 35.2
Ø34.9
Ø28.6
Ø22.2
35.2 or more
Ø41.3
Ø34.9
Ø22.2
Equivalent to HP
Gas side
005 to 012
0.8 to 1.25
Ø9.5
015 to 018
1.7 to 2.0
Ø12.7
024 to 056
2.5 to 6.0
Ø15.9
072 to 096
8.0 to 10.0
Ø22.2
No.
Title
Use part
Remarks
Terminal
Liquid side
Indoor unit
branching section
(6)
Ô
Ø12.7
connecting pipe
Indoor unit
Ø12.7
Ø12.7
Ø15.9
Ø19.1
Ø19.1
Ø19.1
Y-shaped
(7)
branching joint
Branching section
*3, *4
Liquid side
Ø15.9
Ø19.1
Ø19.1
Ø22.2
Branching
(8)
header
Branching section
*3, *4, *5
Outdoor unit
connection
(9)
Branching section
piping kit
*6
Flow Selector
Flow Selector unit
(10)
Ô
unit
*7
Indoor unit
Liquid side
Ø6.4
Ø6.4
*1: Use the same size as the main pipe if it is larger than the main pipe.
*2: Use a suction gas pipe and a liquid pipe for the two pipes branching downstream from the flow selector unit and the dedicated cooling circuit.
Ø9.5
*3: Select the branch pipe of the first branch according to the outdoor capacity code.
*4: Select according to the outdoor unit capacity code if the total of the indoor capacity codes exceeds the outdoor unit capacity code.
Ø12.7
*5: It is possible to select up to a maximum capacity code total AP056 (6 hp) for the first circuit after the header branch.
When using a branch header for the first branch with an outdoor unit capacity code of 33.5 (12 hp equivalent) or more and 73.0 (26 hp equivalent) or less,
use RBM-HY2043FE (4 branches) and RBM-HY2083FE (8 branches) regardless of the total value of the capacity codes of the downstream indoor units.
And, a branch header cannot be used as the first branch if the performance rank is over 73.0 (26 hp equivalent).
*6: The downstream starting point is the main pipe.
*7: If the performance rank is over 117.5 (42HP equivalent), "Flow Selector unit" is available for only Multi port type.
– 66 –
Selection of pipe size
Equivalent to
Capacity rank
Length of piping
Gas side
HP
15 m or less real length
005 to 012
0.6 to 1.25
Exceeds 15 m real length
15 m or less real length
015 to 018
1.7 to 2.0
Exceeds 15 m real length
024 to 056
2.5 to 6.0
-
072 to 096
8.0 to 10.0
-
Total capacity code of indoor units
Model name
Equivalent to capacity
Equivalent to HP
For 3 piping
Below 18.0
Below 6.4
RBM-BY55FE
18.0 to below 40.0
6.4 to below 14.2
RBM-BY105FE
40.0 to below 70.5
14.2 to below 25.2
RBM-BY205FE
70.5 or more
25.2 or more
RBM-BY305FE
Total capacity code of indoor units
Equivalent to
Equivalent to HP
For 3 piping
capacity
Below 40.0
Below 14.2
RBM-HY1043FE
For 4
branches
40.0 to below 70.5
14.2 to below 25.2
RBM-HY2043FE
Below 40.0
Below 14.2
RBM-HY1083FE
For 8
branches
40.0 to below 70.5
14.2 to below 25.2
RBM-HY2083FE
Total capacity codes of outdoor units at the downstream side
Equivalent to
Equivalent to HP
capacity
Below 73.0
Below 26.0
73.0 or more
26.0 or more
Single port type
Total capacity codes of connected indoor units
Max. No. of
Equivalent to
Equivalent to HP
connected indoor
capacity
unit
Below 11.2
Below 4.0
Below 5
11.2 to below 18.0
4.0 to below 6.4
Below 10
18.0 to 28.0 or less
6.4 to below 10.0
Below 10
Multi port type
Max No. of
Equivalent to
Equivalent
No. of
connected indoor
capacity
to HP
branch
unit in a branch
4
Below 18.0
Below 6.4
10
6
Remarks
Liquid side
Ø9.5
Ø6.4
Ø12.7
Ø9.5
Ø12.7
Ø6.4
Ø15.9
Ø9.5
Ø15.9
Ø9.5
Ø22.2
Ø12.7
For 2 piping
RBM-BY55E
RBM-BY105E
RBM-BY205E
RBM-BY305E
Model name
For 2 piping
RBM-HY1043E
RBM-HY2043E
RBM-HY1083E
RBM-HY2083E
Model name
RBM-BT14FE
RBM-BT24FE
Model name
RBM-Y1123FE✽
RBM-Y1803FE✽
RBM-Y2803FE✽
Model name
RBM-Y1801F4PE*
RBM-Y1801F6PE*
132-EN