3. Check that the speaker cable connected to the product is
not in contact and shorting out.
4. The Microprocessor 25 pin (Power Down) is outputting
the "H" signal when the power is turned ON. (If the 25pin
continues to be in the "L" state after the power is turned
on, the MAIN PWB circuit , the IC60 and its adjacent cir-
cuits are developing an abnormality.)
NOTE : HOW TO RECOVER FROM SYSTEM ERROR
(STANDBY LED flickering) The product can recov-
er by turning on STANDBY on the remote control-
ler after the above errors are rectified.
Check 3
• Detection of Overcurrent over 200 msec on POW-
ER AMP (_P CUR FAIL)
When the power is turned on or while the product is in nor-
mal operation, an abnormality occurs with the POWER
AMP, and an overcurrent of 200msec or more (500msec or
more when the power is on) is detected on the CPU 120
pin.
• Detection of an abnormality on +/-12V Supply or
Power Amp power supply (_P LINE FAIL)
When the power is turned on or while the product is in nor-
mal operation, an abnormality occurs with the +/-12V sup-
ply or POWER AMP power supply with an abnormality
detected on CPU 122 pin.
When errors like the above abnormalities are detected, the
software automatically puts the product into STANDBY
mode, with the STANDBY LED flickering approximately
every 125msec.
NOTE : This SYSTEM ERROR cannot be rectified by
users. In order to power on the product, please do
the following.
: Hold down "SURROUND MODE", "EXIT" &
"CLEAR" at the same time for 3 seconds or
more. However, if any problem remains with
the product, the SYSTEM ERROR will occur
again.
Points to be checked on the circuit
1. Check that the 120 pin (_P CUR FAIL) of the
microprocessor is outputting "H". (If the 120pin is in the
L-state for 500msec or more after the power is turned on,
the POWER AMP circuit is developing an abnormality.)
2. Make sure that the 122pin of the microprocessor
(POWER LINE FAIL) is "H". (If the 122 pin is in the
L-state for 2 seconds or more after the power is turned
on, the +/-12V power supply or the POWER AMP power
supply is developing an abnormality.)
3. 製品に接続されている Speaker Cable が +/- 又は
RearPanel 等に Short していないか確認する。
4. 電源 ON 時にマイコンの 25pin (Power Down) が "H" に
なっていることを確認する。
( 電源 ON しても、25pin が "L" 状態で継続している場合
は MAIN PWB 上の IC60 及び周辺回路に異常が発生して
いる )
復帰操作 :
System Error (STANDBY LED の点滅 ) からの復帰は
上記の不具合を改善後リモコンの STANDBY ON 操作
で復帰できます。
Check 3
・ Power Amp の 200msec 以上の過電流検出
(̲P CUR FAIL)
電源 ON 時又は通常動作時に Power Amp に異常が発生し、
CPU の 120pin で Power Amp の過電流が 200msec 以
上 (Power ON 時は 500msec 以上 ) 検出された場合。
・ +/- 12V Supply 又は、Power Amp 用電源の異常
検出 (̲P LINE FAIL)
電源 ON 時又は通常動作時に +/-12V 電源又は、Power 
Amp 用の電源に異常が発生し、CPU の 122pin で異常検
出がされた場合。
上記の様な異常検出がされた場合は、製品を STANDBY 状態
にして、STANDBY LED を約 125 msec 間隔で点滅させま
す。
ご注意 : この System Error は User が通常動作に復帰さ
せることは出来ません。製品の電源を ON させる
場合は次の操作を行います。
復帰操作 :
"SURROUND MODE" + "EXIT" + "CLEAR"
ボタンを同時に押して 3 秒以上保持する。
但し、製品に不具合が残っている場合は再び
SYSTEM ERROR が働きます。
回路上の確認箇所
1. 電源 ON 時にマイコンの 120pin (̲P CUR Fail) が "H"
になっていることを確認する。
(120pin が電源 ON してから 500 msec 以上 "L" 状態が
継続している場合は POWER AMP 回路に異常が発生して
いる )
2. 電源 ON 時にマイコンの 122pin (Power Line Fail) が
"H" になっていることを確認する。
(122pin が電源 ON してから 2 秒以上 "L" 状態が継続し
ている場合は +/-12V 電源又は、Power Amp 用の電源
に異常が発生している )
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr6004/fbSr6004/n1bSr6004/u1bSr6004/k1sgSr6004/n1sg

Table of Contents