INSTALLATION
Caution!
On completion of the cooker installation,
the tightness of all connections should be
checked, e.g. applying water with soap.
Do not use fire to check tightness.
Fix the cooker to the back wallwith
2 chains
Anti tilt chains are located at the rear of the
appliance and must be secured to the wall
behind the appliance to prevent accidental
tipping/tilting. The chain length must be as
short as practicable to avoid appliance tilting
forward and also diagonal to avoid appliance
moving sideways.
Flexible hose connection
In case the appliance is connected by
means of a flexible hose, the position A of
the hose is not permissible.
In case the connection hose is made of
metal, position A is permissible.
A
D
B
C
9
Beginning of operation
Start using the appliance in accordance
with the instructions for use.
Lit up all burners and check the stability of
the flame with high and low setting. Adjust
air intake if necessary. After that, take time
and explain the operation and control of
the appliance to the user and read with him
the instructions for use.
Liquefied gas connection
10 Gasket
11 Connection R 1/2
10
11
Adapting the cooker to
another type of gas
This operation may only be carried out by
an appropriately authorised fitter.
The cooker is supplied with natural gas
(NG 1.0kpa).If the cooker is to be supplied
with differs from the gas provided for the
cooker by the manufacturer, burner nozzles
must be exchanged and the flame needs to
be adjusted.
In order to adapt the cooker to burn a
different type of gas, you should:
● Exchange nozzles (see tables below),
Adjust the "economical" flame.
If you need to replace the natural gas
(NG 1.0kpa) , please contact the service center.
According to NG install instruction:
Use M7 sleeve to replace LPG nozzle to be NG nozzle
Adjust NG pressure, ignite to check burner minimum
flame status, adjusting damping hole till flame is stable.
INSTALLATION
Caution!
The cookers provided by the manufacturer have burners which are factory-adapted to
use the gas specified on their data plates and guarantee cards.
Burner
Upright
Burner
Gas type
Auxiliary
Semi-rapid
Natural gas
Wok
Oven
540mm
Auxiliary
Semi-rapid
Universal
LPG
Wok
Oven
x
Re-arming from liquid
Burner flame
gas
to natural gas
1. Exchange a burner nozzle for the
Full
appropriate type according to the
nozzle table
2. Unscrew an adjusting bolt slightly
Economical
and adjust the flame size.
In order to perform adjusting operations, take off the knobs. Adjusting elements of the oven
burner are accessible after drawing out the oven chamber floor.
Surface burners applied do not require adjustment of primary air. A correct flame has
distinct internal cones of blue and green colour. A short, humming flame or long, yellow
and smoking one, without clearly outlined cones, shows improper quality of gas in the
household piping or a damaged or soiled burner. In order to check a flame, heat a burner
for around 10 minutes with a full flame, and next turn the valve knob to the economical
flame position. The flame should not go out or jump onto the nozzles.
Exchange of a burner
nozzle : unscrew the
nozzle with special socket
spanner No 7 and replace
with a new one according
to a type of gas (see tables)
Knobs should be adjusted with the
burner switched on and set to the
economical flame position, using an
adjustment screwdriver of the 2.5mm size.
Injector
TPP
NGC
Size(mm)
(kPa)
(MJ/h)
0.87
3.6
1.10
6.3
1.0
1.65
12.6
1.39
10.8
0.53
3.6
0.68
6.3
2.75
0.95
12.6
0.89
10.8
Re-arming from natural
gas
to liquid gas
1. Exchange a burner nozzle for the
appropriate type according to the
nozzle table.
2. Screw in an adjusting bolt slightly
to the end and check the flame size.