Safety; Power Failure - Crown Royal Stoves RS7200 Owner's Manual

Table of Contents

Advertisement

DAILY FUELING & FIRING ROUTINE
Prior to opening the fuel door, pull the damper plate rod out, open the control panel, turn the inducer fan
switch off and wait 60 seconds. After the 60 seconds has passed, open the fuel door slowly and stand
behind the door so that the door is between you and the fire box. Allow another 60 seconds to pass before
raking the coals, shaking down the ashes and filling the fire box. Failure to wait may cause an injury from a
fire flare back.
Since the inducer blows air into the ash pan area it is critical to remove the ashes daily even though the
ash pan area is not full. Store ashes in a covered metal container until all cinders have thoroughly cooled
prior to dispersal.
Do not load the fire box more than thirty percent (30%) with coal. If additional fuel is added you will not
maintain a hot enough burn and your efficiency rate will deteriorate. Only add enough coal to provide heat
until the next fueling time. Overfilling the fire box will cause the fire to smolder, create excessive creosote
and result in more fuel being consumed.

SAFETY

Whenever the loading door is to be opened, it should always be cracked slightly to allow oxygen to enter
and burn off any combustion gases that are present before fully opening. Failure to do this could result in
sudden ignition of the unburned gases when the door is opened.
A stove should never be filled with excess coal so that the flue gas exit is blocked or impeded in any way.
Burning coal generates carbon monoxide and if the flue gas exit is blocked the carbon monoxide can be
forced into the area the stove is heating and have fatal consequences.
STARTING DURING A PROLONGED POWER FAILURE
During a prolonged power failure, where no power is being sent to the furnace, do not load with new fuel
or try to start a new fire. It is recommended that you contact your local dealer or Greentech
Manufacturing, Inc. to find out what size of generator is needed to keep your furnace running. Once an
approved generator is connected to the stove, the unit may be started normally.
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs7300Rs7400