Page 1
__________ PELLET BOILER BIODOM C15 Instructions for use, maintenance and installation Instructions for use, maintenance and installation Instructions for use, maintenance and installation __________...
Page 2
Biodom C15 Biodom C15 We thank you for your purchase of Biodom boiler. We ask to thoroughly read instructions for use before installing and using your pellet boiler Biodom. Heating appliances (in the following: "pellet boiler" or "boiler") of company Biodom 27 d.o.o. (in the following: Biodom) are manufactured and tested in accordance with safety requirements of European Directives in force.
If the instructions get lost, request for a new copy of instructions from the manufacturer, authorized reseller or repairman. RESPONSIBILITY OF MANUFACTURER In providing these instructions, Biodom 27 d.o.o. rejects any civil or penal liability, direct or indirect, due to: accidents caused by non-compliance with standards and specifications from these •...
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 Harmonized standards: EN 303-5:2012 • EN 60335-1:2012+A11:2014 • EN 6100-6-3:2007+A1:2011 • EN ISO 12100:2010 • EN 60335-2-102:2006+A1:2010 • EN 60204-1:2006+A1:2009 •...
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 possibility of simultaneous use of generator for connection with other equipment. • If the results of all above provided checks are positive, installation may proceed. Carefully heed to instructions provided by the manufacturer, as well as safety and fire prevention standards in force.
Page 9
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 Flue pipe Figure 1: Minimum distance of boiler from boiler room walls If the pellet boiler is installed in a boiler room, where there are other devices, which drain air (other boiler, various suction fans etc.), make sure that the volume of air intake is sufficient for safe...
Page 10
– Ø 130 mm. If the flue does not ensure appropriate extraction of smoke gases, it can also come do improper operation and, consequently, to alarm from boiler Biodom C15. It is advisable that the flue is inspected by an expert before installing boiler Biodom C15.
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 ATTENTION Never turn off the boiler by pulling the electrical cable from the socket, while fire is still burning in the boiler. This could damage the boiler and seriously jeopardize its functioning.
Page 12
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 Smoke can be extracted through a traditional flue pipe (see figure below) provided that the following rules are met: check condition of flue pipe maintenance. For proper maintenance and/or restoration •...
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 Direction of smoke gases 5 % or more Figure 4 Figure 5 3.3. INSULATION AND DIAMETER OF HOLES IN THE ROOF Once the position of boiler installation is determined, a hole for passage of smoke pipes must be made.
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 If there are other combustion devices in the room, a sufficient amount of air must be ensured, which is required for proper combustion of all combustion devices, and regard all technical properties of already installed ventilation systems in the boiler room.
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 Figure 8 If the power supply cable is damaged, it must be replaced. It can only be replaced by an authorized person.
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 ATTENTION The pellet boiler operates by creating negative pressure in the combustion chamber. Therefore, ensure that the extraction of smoke gases is thermally sealed.
Page 17
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 ATTENTION DURING PELLET BOILER OPERATION, CHILDREN ARE PROHIBITED TO COME NEAR OR PLAY WITH IT! When using a combustion device, it is advisable to take special care of the following: during boiler operation DO NOT approach it and do not touch the doors of combustion •...
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 INSTRUCTIONS FOR SAFE IGNITION AND CLEANING OF BOILER NEVER use fuel oil, lamp oil or any other oil or any other flammable liquid to ignite the pellet boiler.
Page 19
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 2 The hole for inserting the heating element to burn fuel 1 For the best operation of the stove, all holes must be...
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 ATTENTION Be careful that the sealant rope under the edge of combustion chamber is not damaged. If the sealant rope is damaged, contact an authorized service centre.
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 GENERAL BOILER CLEANING AFTER THE END OF SEASON OR BEFORE THE START OF SEASON: Ensure that the pellet boiler and ashes in it are cool! Disconnect power supply! At the end of heating season, disconnect the boiler from electrical network.
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 ATTENTION In the event of fire in the flue pipe, all persons and animals must leave the area, then immediately disconnect power supply from the main switch or socket (if it is possible without risk) and call the fire department.
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 ATTENTION Persons with back injuries and pregnant women should avoid lifting pellet bags. ATTENTION The manufacture shall in no way be held liable for damages arising from the use of poor quality pellets, as well as for poor functioning of the boiler due to poor quality of used pellets.
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 DESCRIPTION AND OPERATION OF CONTROL DEVICE DESCRIPTION OF KEYBOARD WITH DISPLAY (plastic keyboard) Button - for adjustment Upper display Button + for adjustment...
Page 25
Biodom C15 Biodom C15 Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 Biodom C15 Biodom C15 Display during boiler operation in burning phase Display during boiler operation in burning phase...
Biodom C15 Biodom C15 Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 Biodom C15 Biodom C15 MENU button Short press in basic display shows set value of water temperature...
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 9.2. BOILER SHUTDOWN When pressing and holding the ON/OFF button for more than half a second (during boiler operation), the display shows ON, and the boiler starts shutdown sequence once the button is released. Dosing...
Page 28
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 Figure 12: Diagram of timer settings...
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 9.5. INDICATIONS AND MESSAGES ON DISPLAY Indication on Explanation of message and status of the boiler display The boiler is at a standstill.
Page 30
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 When water temperature in the boiler, even with minimum power, reaches set temperature, the boiler enters phase COOL FLUID and cools down. The boiler restarts automatically when the water in the boiler cools down under set value.
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 MENU When holding MENU button, menus scroll. To select a certain menu, release the button when it is displayed. Descriptions of individual menus are provided below:...
Warranty for all Biodom products is valid for 24 months from the date of first start Warranty for all Biodom products is valid for 24 months from the date of first start-up, given that a regular maintenance inspection is performed no later than 12 months from the dat regular maintenance inspection is performed no later than 12 months from the dat regular maintenance inspection is performed no later than 12 months from the date of start-up.
Page 40
• if the user does not comply with the instructions for use and maintenance; • if defects or faults arise on the heating device Biodom due to defects on equipment of other • manufacturers. Liability of company Biodom 27 d.o.o. is limited to unit supply. Unit must be installed properly in...
Page 41
As representative/salesman is considered any natural person or legal entity authorized for sales of products to end users of this warranty. NOTE: Biodom 27 d.o.o. shall not be held liable for any damage and consequences, even if these are a consequence of replacement of malfunctioning part of the boiler.
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 Voltage 220 V Current at maximum electrical consumption during boiler operation 1,80 A frequency 50 Hz Maximum consumption of power during boiler operation...
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 __________ INSTRUCTIONS FOR FIRST START-UP __________...
Page 45
Benefits of combustion device Biodom f combustion device Biodom C15 lie in advanced technology that enables automatic identification of oxygen contents in air, lie in advanced technology that enables automatic identification of oxygen contents in air,...
Page 46
Biodom C15 Biodom C15 Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 Biodom C15 Biodom C15 Button DOWN Press during operation to decrease set power. When pressing MENU button beforehand, this button decreases When pressing MENU button beforehand, this button decreases desired water temperature in the boiler.
Page 47
"Cool flui" – state of shutting down, indicated on the display when combustion device Biodom • C15 reaches set temperature of heating water in the boiler with addition for regulation (if the temperature of heating water is set to 70 °C, the boiler enter "cool flui" state at 75 °C). When the boiler finishes "Cool flui"...
Page 48
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 IZJAVA PROIZVAJALCA O SKLADNOSTI DECLARATION OF CONFORMITY Naziv proizvajalca/Producer: Biodom 27 d.o.o. OIC Hrpelje 4a, 6240 Kozina, Slovenia Izjavlja, da v nadaljevanju opisani stroj/Declares that that the below...
Page 49
Biodom C15 Biodom C15 | | | | instructions for use, maintenance and installation | Biodom C15 Biodom C15 Preizkus naprave je opravila Kiwa Cermet Italia S.p.A., Viale Venezia, 45 31020 San Vendemiano (TV), številka preizkusa je PKC0001277./The test of the pellet stove was carried out by the Kiwa Cermet Italia S.p.A., Viale Venezia, 45 31020 San Vendemiano (TV), the number of the report is PKC0001277.
Need help?
Do you have a question about the C15 and is the answer not in the manual?
Questions and answers