Page 1
__________ PELLET BOILER BIODOM 27 A Instructions for use, maintenance and installation __________ March 2019...
Page 2
Biodom 27 A | instructions for use, maintenance and installation | March 2019 GENERAL INFORMATION BUYER: NAME AND SURNAME: STREET AND HOUSE NO.: CITY: PHONE NO/GSM: __________________E-MAIL: DATE OF SALE: INVOICE NUMBER: PRODUCT TYPE: SERIAL NUMBER: DURATION OF WARRANTY: 2 YEARS...
Page 3
Biodom 27 A | instructions for use, maintenance and installation | March 2019...
Page 4
Biodom 27 A | instructions for use, maintenance and installation | March 2019 We thank you for your purchase of Biodom boiler. We ask to thoroughly read instructions for use before installing and using your pellet boiler Biodom. Heating appliances (in the following: "pellet boiler"...
Biodom 27 A | instructions for use, maintenance and installation | March 2019 INDEX PURPOSE OF INSTRUCTIONS FOR USE ................7 1.1. UPDATES ..........................7 RESPONSIBILITY OF MANUFACTURER ................. 7 2.1. BASIC PREVENTIVELY REQUIRED STANDARDS ................. 7 2.2. TRANSPORTATION AND HANDLING OF PELLET BOILER ............8 2.3.
Page 6
Biodom 27 A | instructions for use, maintenance and installation | March 2019 BOILER CONNECTION INSTRUCTIONS ................41 CONNECTION SCHEMES ....................44 17.1. SCHEME NR.1: HEATING ONLY ....................44 17.2. SCHEME NR.2: HEATING HOUSEHOLD HOT WATER .............. 46 17.3. SCHEME NR.3: HEATING WITH MULTIPLE SYSTEMS .............. 48...
If the instructions get lost, request for a new copy of instructions from the manufacturer, authorized reseller or repairman. RESPONSIBILITY OF MANUFACTURER In providing these instructions, Biodom 27 d.o.o. rejects any civil or penal liability, direct or indirect, due to: •...
Biodom 27 A | instructions for use, maintenance and installation | March 2019 • SIST EN ISO 12100-1: 2004 and A1: 2010; • SIST EN ISO 12100-2: 2004 and A1: 2010; • SIST EN 303-5: 2012; • 61000-6-3: 2007; •...
Biodom 27 A | instructions for use, maintenance and installation | March 2019 If the results of all above provided checks are positive, installation may proceed. Carefully heed to instructions provided by the manufacturer, as well as safety and fire prevention standards in force.
Page 10
Biodom 27 A | instructions for use, maintenance and installation | March 2019 Flue pipe EXAMPLE 1 Flue pipe EXAMPLE 2 Flue pipe EXAMPLE 3 Figure 1: Minimum distance of boiler from boiler room walls If the pellet boiler is installed in a boiler room, where there are other devices, which drain air (other boiler, various suction fans etc.), make sure that the volume of air intake is sufficient for safe operation...
Page 11
– Ø 130 mm. If the flue does not ensure appropriate extraction of smoke gases, it can also come do improper operation and, consequently, to alarm from boiler Biodom 27 A. It is advisable that the flue is inspected by an expert before installing boiler Biodom 27 A.
Biodom 27 A | instructions for use, maintenance and installation | March 2019 In case of a grid on the facade, draught opening must be 100 cm² or larger. The device operates at 220 V – 50 Hz. Make sure that the electrical cables are not laid under the boiler, that they are far away from hot surfaces and that they do not touch sharp parts, which could damage them.
Page 13
Biodom 27 A | instructions for use, maintenance and installation | March 2019 Flue pipes in poor condition and/or made of unsuitable materials (asbestos, zinced sheet metal etc., with rough or porous surfaces) are prohibited by law and compromise proper boiler operation.
Biodom 27 A | instructions for use, maintenance and installation | March 2019 Direction of smoke gases 5° or Figure 4 Figure 5 3.3. INSULATION AND DIAMETER OF HOLES IN THE ROOF Once the position of boiler installation is determined, a hole for passage of smoke pipes must be made.
Biodom 27 A | instructions for use, maintenance and installation | March 2019 If there are other combustion devices in the room, a sufficient amount of air must be ensured, which is required for proper combustion of all combustion devices, and regard all technical properties of already installed ventilation systems in the boiler room.
Page 16
Biodom 27 A | instructions for use, maintenance and installation | March 2019 Electrical connection The pellet boiler must be connected to electrical network. Power supply cable is 3 m long, white and designated with "220 V". Other connectors are for connecting the pump and room thermostat.
Biodom 27 A | instructions for use, maintenance and installation | March 2019 BOILER COMMISSIONING Boiler commissioning can be performed only by a manufacturer authorized technician, otherwise the warranty is void. INSTRUCTIONS FOR SAFETY OF PERSONS, ANIMALS AND PERSONAL PROPERTY We wish to inform the installer on some general guidelines, which must be complied with for correct installation of pellet boiler.
Biodom 27 A | instructions for use, maintenance and installation | March 2019 • Always use original spare parts. Do not wait for boiler components to wear out before replacing them. Replacing a worn-out part, before it malfunctions, helps prevent injuries, caused by sudden failure of a component, which can seriously jeopardize persons and/or their property.
Biodom 27 A | instructions for use, maintenance and installation | March 2019 • DO NOT lean on the boiler, as it may be unstable and could tip over; • DO NOT use the pellet boiler as support or a fastening item. Do not leave the container cover open;...
Biodom 27 A | instructions for use, maintenance and installation | March 2019 ATTENTION Be careful that the sealant rope under the edge of combustion chamber is not damaged. If the sealant rope is damaged, contact an authorized service centre.
Biodom 27 A | instructions for use, maintenance and installation | March 2019 Ensure that the pellet boiler and ashes in it are cool! • For perfect cleaning, vacuum ashes from beneath the combustion container and from combustion chamber every week or at each 200 kg pellet container used (whichever comes sooner).
Biodom 27 A | instructions for use, maintenance and installation | March 2019 IMPORTANT SAFETY INFORMATION You have purchased a product of the highest quality. The supplier is at your disposal in transferring required information. Correct installation of combustion device in accordance with instructions is important to prevent any poor functioning, hazard or risk of fire.
Biodom 27 A | instructions for use, maintenance and installation | March 2019 Figure 11 ATTENTION Persons with back injuries and pregnant women should avoid lifting pellet bags. The manufacture shall in no way be held liable for damages arising from the use of poor quality pellets, as well as for poor functioning of the boiler due to poor quality of used pellets.
Biodom 27 A | instructions for use, maintenance and installation | March 2019 DESCRIPTION AND OPERATION OF CONTROL DEVICE On the display on the left is Clock (time); BoilerTemp (boiler temperature); FlueGasses and Status (boiler status). Clock BoilerTemp FlueGasses Status...
Page 25
Biodom 27 A | instructions for use, maintenance and installation | March 2019 • Clock- shows time; • BoilerTemp (boiler temperature); • FlueGasses (gasses temperature); • Status (displays boiler status); • Actual Power (current power of the boiler); • BackWater (temperature of return water in the boiler);...
Page 26
Biodom 27 A | instructions for use, maintenance and installation | March 2019 • Feeder Avg % (Average percentage of dosing since the last start); • Num. of Ign. (Number of Ignition); • Low.Acc (Lower Accumulator temperature); • Feed.to clean (How much time to clean);...
Page 27
Biodom 27 A | instructions for use, maintenance and installation | March 2019 • 0 (current power); • 15 (water temperature in the boiler) By pressing the Menu button, entering in submenu. Holding Menu button enter in service. Click on the Menu button showsthe Set Boiler Temp submenu (boiler temperature setting);...
Page 28
Biodom 27 A | instructions for use, maintenance and installation | March 2019 Next click on the Menu button: Next click on the Menu button: • Pump Diff. Disable (difference between boiler temperature and return water temperature, when the pump stops);...
Page 29
Biodom 27 A | instructions for use, maintenance and installation | March 2019 Next click on the Menu button: • Fire off • Pump off • All off...
Biodom 27 A | instructions for use, maintenance and installation | March 2019 ALARM STATUSES ALARM FIRE Unsuccessful ignition Are there pellets in Fill the container with pellets the container? Mandatory use of pellets up to 30mm! Is the burner 1.
Page 32
Biodom 27 A | instructions for use, maintenance and installation | March 2019 ALARM PELL No pellets in the container Are there pellets in Fill the container with pellets the container? Mandatory use of pellets up to 30mm! Is the STB protection...
Page 33
Biodom 27 A | instructions for use, maintenance and installation | March 2019 ALARM DIRTY Fan 1 reached maximum speed, but the air flow is insufficient 1. Secure the air intake in the boiler room 2. Check entry point of air into boiler 3.
Page 34
Biodom 27 A | instructions for use, maintenance and installation | March 2019 ALARM STB Safety thermostat is activated 1. Cool the boiler and press STB button again 2. If the error remains, check set boiler temperature Is the boilers...
Page 35
Biodom 27 A | instructions for use, maintenance and installation | March 2019 ALARM TC1 Electronic does not detect flue gas sensor Service 1. Replace the sensor 2. Replace the electronic Is the sensor connected? Connect the sensor to correct position on...
Page 36
Biodom 27 A | instructions for use, maintenance and installation | March 2019 ALARM NTC1 Electronic does not detect boiler water temperature sensor Service 1. Replace the sensor 2. Replace the electronic Is the sensor connected? Connect the sensor to correct position on...
Biodom 27 A | instructions for use, maintenance and installation | March 2019 INFORMATION REGARDING DESTRUCTION AND DISPOSAL OF BOILER Destruction and disposal of pellet boiler is sole responsibility of the owner, who must act in accordance with laws in force in his country regarding safety, respect and protection of environment.
Biodom 27 A | instructions for use, maintenance and installation | March 2019 TECHNICAL CHARACTERISTICS OF MODEL BIODOM 27 A Minimal Nominal Thermal power 7,8 kW 26,9 kW Efficiency 90,50 % 90,80 % CO emissions (at 10 % O 33 mg/m³...
Biodom 27 A | instructions for use, maintenance and installation | March 2019 _______ INSTRUCTIONS FOR INSTALLERS __________ This part of the instructions is intended solely for installer and contains all key information for installation and connection of combustion device Biodom 27 A.
"there cannot be a closing element, which could prevent indication of pressure in the boiler in the time of filling"). On the right side of Biodom 27 A is a provided DN20 connection for filling release tap. Filling release tap is intended for filling or...
Page 42
Biodom 27 A | instructions for use, maintenance and installation | March 2019 • When connecting the boiler Biodom 27 A to central heating system you must use mechanical elements, which prevent uncontrolled circulation of hot heating water through the boiler (grav- ity block, spring non-return valve, solenoid zone valve, electromotor zone valve...).
Page 43
Biodom 27 A | instructions for use, maintenance and installation | March 2019 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21: Activating thermal safety...
Biodom 27 A | instructions for use, maintenance and installation | March 2019 CONNECTION SCHEMES 17.1. SCHEME NR.1: HEATING ONLY Connection scheme 1...
Page 45
Biodom 27 A | instructions for use, maintenance and installation | March 2019 Connection scheme 1...
Biodom 27 A | instructions for use, maintenance and installation | March 2019 17.3. SCHEME NR.3: HEATING WITH MULTIPLE SYSTEMS This type of connection always requires a hydraulic switch. Connection scheme 3...
Page 49
Biodom 27 A | instructions for use, maintenance and installation | March 2019 Electrical scheme 3...
Use only original spare parts. WARRANTY TIME CONDITIONS: Warranty for all Biodom products is valid for 24 months from the date of first start-up, given that a regular maintenance inspection is performed no later than 12 months from the date of start-up.
Page 51
As representative/salesman is considered any natural person or legal entity authorized for sales of products to end users of this warranty. NOTE: Biodom 27 d.o.o. shall not be held liable for any damage and consequences, even if these are a consequence of replacement of malfunctioning part of the boiler.
Page 52
Biodom 27 A | instructions for use, maintenance and installation | March 2019 OVERVIEW OF SERVICES SERVICE 1 (SERVICE IN THE WARRANTY PERIOD) NUMBER OF REPORT ON ANNUAL REVIEW OF BOILER: TYPE OF WORK: REGULAR MAINTENANCE REGULAR MAINTENANCE +3 RECLAMATION...
Page 53
Biodom 27 A | instructions for use, maintenance and installation | March 2019 SERVICE 4 NUMBER OF REPORT ON ANNUAL REVIEW OF BOILER: TYPE OF WORK: REGULAR MAINTENANCE REGULAR MAINTENANCE +3 RECLAMATION ENERGENT MANUFACTURER: OTHER: CLIENTS SIGNATURE: STAMP AND SIGNATURE OF SERVISER:...
Page 54
Biodom 27 A | instructions for use, maintenance and installation | March 2019...
Page 55
COMMISSIONING OF THE DEVICE DATE OF COMMISSIONING: AUTHORIZED COMPANY NAME: STREET AND HOUSE NO.: CITY: PHONE NO.: NAME AND SURNAME OF SERVISER: SERIAL NUMBER: STAMP AND SIGNATURE OF SERVISER: (FILLS IN AN AUTHORIZED SERVICE COMPANY) COMPLETED FORM RETURN TO BIODOM...
Page 57
INSTALLATION OF DEVICES DATE OF INSTALLATION: NAME OF THE INSTALLATION COMPANY: STREET AND HOUSE NO.: CITY: PHONE NO./GSM: E-MAIL: NAME AND SURNAME OF INSTALLER: SERIAL NUMBER: STAMP AND SIGNATURE OF INSTALLER: (FILLS IN AN INSTALLATION COMPANY) COMPLETED FORM RETURN TO BIODOM...
Need help?
Do you have a question about the 27 A and is the answer not in the manual?
Questions and answers