Page 1
__________ PELLET BOILER BIODOM BIODOM 27 C5 Valter Valter DF 34 Instructions for use, maintenance and installation Instructions for use, maintenance and installation Instructions for use, maintenance and installation ________ Version 1.0 / Ma y 2017...
Page 2
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 We thank you for your purchase of Biodom boiler. We ask to thoroughly read instructions for use before installing and using your pellet boiler Biodom.
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 INDEX PURPOSE OF INSTRUCTIONS FOR USE ..............5 1.1. UPDATES ..........................5 RESPONSIBILITY OF MANUFACTURER ..............5 2.1.
Page 4
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 9.3. BOILER ACTIVATION ....................... 27 9.4. TIME PROGRAMME SETTING ....................28 9.5. INDICATIONS AND MESSAGES ON DISPLAY ................30 MENU ........................
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 PURPOSE OF INSTRUCTIONS FOR USE The purpose of instructions for use is that the user takes all necessary measures and prepares all required equipment to ensure safe and proper use of combustion device.
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 Harmonized standards: SIST EN ISO 12100-1: 2004 and A1: 2010; • SIST EN ISO 12100-2: 2004 and A1: 2010;...
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 possibility of outside air intake; • possibility of simultaneous use of generator for connection with other equipment.
Page 8
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | instructions for use, maintenance and installation | version 1.0 May 2017 version 1.0 May 2017 Flue pipe...
Page 9
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 If the smoke duct passes through a ceiling, it must be properly insulated using diaphragm of non- combustible insulation material.
Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 90° joint requires a deduction of 1 m in line length. If the air supply is longer, diameter of air intake pipe must be increased.
Page 11
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 Regarding dimensions and material, from which it is made, the flue pipe must conform to standards UNI 9615-9731, UNI 10683 - EN1856-1.
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 Figure 4 Figure 5 3.3. INSULATION AND DIAMETER OF HOLES IN THE ROOF Once the position of boiler installation is determined, a hole for passage of smoke pipes must be made.
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 If there are other combustion devices in the room, a sufficient amount of air must be ensured, which is required for proper combustion of all combustion devices, and regard all technical properties of already installed ventilation systems in the boiler room.
Page 14
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 Figure 8a, b White cabel – Boiler supply (220 V) Black cabel – Pump...
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 If the pellet boiler is placed on a wooden floor, it is advisable to protect the floor in •...
Page 17
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 ATTENTION DURING PELLET BOILER OPERATION, CHILDREN ARE PROHIBITED TO COME NEAR OR PLAY...
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 INSTRUCTIONS FOR SAFE IGNITION AND CLEANING OF BOILER NEVER use fuel oil, lamp oil or any other oil or any other flammable liquid to ignite the pellet boiler.
Page 19
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 Figure 10 ATTENTION Be careful that the sealant rope under the edge of combustion chamber is not damaged. If the sealant rope is damaged, contact an authorized service centre.
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 6.2. CONTROL AND PARTS REQUIRING MAINTENANCE CHECK THE FOLLOWING ITEM AND MAKE SURE THAT THE PELLET BOILER IS OPERATING PROPERLY.
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 IMPORTANT SAFETY INFORMATION You have purchased a product of the highest quality. The supplier is at your disposal in transferring required information. Correct installation of combustion device in accordance with instructions is important to prevent any poor functioning, hazard or risk of fire.
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 Figure 11 ATTENTION Persons with back injuries and pregnant women should avoid lifting pellet bags.
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 When handling pellets, be careful not to scatter them. If you fill the pellet container with sawdust, it can block the pellet dosing system.
Page 24
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | instructions for use, maintenance and installation | version 1.0 May 2017 version 1.0 May 2017 Display during boiler operation in burning phase...
Page 25
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | instructions for use, maintenance and installation | version 1.0 May 2017 version 1.0 May 2017 MENU button...
Page 26
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017...
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 9.1. BOILER DURING OPERATION The display shows current operation phase (e.g. TestFire, HeatUp etc.). Upper display shows set and actual boiler power alternately every 5 seconds.
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 9.4. TIME PROGRAMME SETTING Press and hold (until TEN displays) MENU button to access time programme menu.
Page 29
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 Navigating through the timer menu...
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 9.5. INDICATIONS AND MESSAGES ON DISPLAY Indication on Explanation of message and status of the boiler display The boiler is at a standstill.
Page 31
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 When water temperature in the boiler, even with minimum power, reaches set temperature, the boiler enters phase COOL FLUID and cools down. The boiler restarts automatically when the water in the boiler cools down under set value.
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 MENU When holding MENU button, menus scroll. To select a certain menu, release the button when it is...
Page 33
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 Figure 13: Menu description Burning chamber Incoming air Adjusting the Selecting the cleaning cycle...
Warranty for all Biodom products is valid for 24 months from the date of first start Warranty for all Biodom products is valid for 24 months from the date of first start-up, given that a regular maintenance inspection is performed no later than 12 months from the date of start regular maintenance inspection is performed no later than 12 months from the date of start regular maintenance inspection is performed no later than 12 months from the date of start-up.
Page 42
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 GENERAL WARRANTY CONDITIONS: 1. We declare: that the product will function flawlessly in the warranty period, if used in accordance with •...
Page 43
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 performed by qualified personnel, defined by the manufacturer or representative/salesman (and/or under his supervision and liability), who assumes full responsibility for final installation and subsequent correct operation of installed product.
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 Voltage 220 V Current at maximum electrical consumption during boiler operation 1,80 A...
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 __________ INSTRUCTIONS FOR INSTALLERS __________ This part of the instructions is intended solely for installer and contains all key information for...
(enable that the pressure gauge indicates pressure in the boiler and system; in the time of filling "there cannot be a closing element, which could pre- vent indication of pressure in the boiler in the time of filling"). On the right side of Biodom 27...
Page 48
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 is a provided DN20 connection for filling release tap. Filling release tap is intended for filling or emptying the heating system and boiler.
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 18.3. SCHEME NR.3: HEATING WITH MULTIPLE SYSTEMS This type of connection always requires a hydraulic switch.
Page 55
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 Electrical scheme 3...
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 __________ INSTRUCTIONS FOR FIRST START-UP __________...
Page 57
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 Biodom 27 is a combustion device for heating with pellets. Benefits of combustion device Biodom 27 lie in advanced technology that enables automatic identification of oxygen contents in air, automatic identification of flue draught and automatic identification of pellet quality.
Page 58
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 "Igni test" – checking ignition, display also changes between igni test and P0 d5, and tempera- •...
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 DECLARATION OF CONFORMITY IZJAVA PROIZVAJALCA O SKLADNOSTI DECLARATION OF CONFORMITY Naziv proizvajalca/Producer: Biodom 27 d.o.o.
Page 60
Biodom 27 C5 Biodom 27 C5 Biodom 27 C5 | | | | instructions for use, maintenance and installation | version 1.0 May 2017 Preizkus naprave je opravila Kiwa Cermet Italia S.p.A., Viale Venezia, 45 31020 San Vendemiano (TV), številka preizkusa je 130402174./ The test of the pellet stove was carried out by the Kiwa Cermet Italia S.p.A., Viale Venezia, 45 31020 San Vendemiano (TV), zhe...
Need help?
Do you have a question about the 27 C5 Valter DF 34 and is the answer not in the manual?