Page 1
__________ PELLET BOILER BIODOM 33 Instructions for use, maintenance and installation Instructions for use, maintenance and installation Instructions for use, maintenance and installation __________ Version 1.0 / Jul y 2017...
Page 2
Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 We thank you for your purchase of Biodom boiler. We ask to thoroughly read instructions for use before installing and using your pellet boiler Biodom. Heating appliances (in the following: "pellet boiler"...
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 INDEX 1. PURPOSE OF INSTRUCTIONS FOR USE ..................5 1.1. UPDATES ..........................5 2. RESPONSIBILITY OF MANUFACTURER ..................5 2.1.
Page 4
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 12. INFORMATION REGARDING DESTRUCTION AND DISPOSAL OF BOILER ........40 13. WARRANTY CONDITIONS ....................... 41 14. TECHNICAL CHARACTERISTICS OF MODEL BIODOM 33 ............44 15.
Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 PURPOSE OF INSTRUCTIONS FOR USE The purpose of instructions for use is that the user takes all necessary measures and prepares all required equipment to ensure safe and proper use of combustion device.
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Harmonized standards: SIST EN ISO 12100-1: 2004 and A1: 2010; • SIST EN ISO 12100-2: 2004 and A1: 2010;...
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 existence and suitability of flue pipe cover resistance; • possibility of outside air intake; • possibility of simultaneous use of generator for connection with other equipment.
Page 8
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Flue pipe EXAMPLE 1 Flue pipe EXAMPLE 2 Flue pipe EXAMPLE 3 Figure 1: Minimum distance of boiler from boiler room walls If the pellet boiler is installed in a boiler room, where there are other devices, which drain air (other boiler, various suction fans etc.), make sure that the volume of air intake is sufficient for safe...
Page 9
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 When the pellet boiler is placed, it must be levelled with support feet (horizontal positioning). ATTENTION Smoke gas discharge MUST NOT BE CONNECTED TO: Flue pipe, used by other combustion devices (boilers, stoves, fireplaces etc.);...
Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 The device operates at 220 V – 50 Hz. Make sure that the electrical cables are not laid under the boiler, that they are far away from hot surfaces and that they do not touch sharp parts, which could damage them.
Page 11
Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Flue pipes in poor condition and/or made of unsuitable materials (asbestos, zinced sheet metal etc., with rough or porous surfaces) are prohibited by law and compromise proper boiler operation.
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 5 % or more Figure 4 Figure 5 3.3. INSULATION AND DIAMETER OF HOLES IN THE ROOF Once the position of boiler installation is determined, a hole for passage of smoke pipes must be made.
Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 If there are other combustion devices in the room, a sufficient amount of air must be ensured, which is required for proper combustion of all combustion devices, and regard all technical properties of already installed ventilation systems in the boiler room.
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Figure 8 White – Boiler supply (220 V) Black – Pump If the power supply cable is damaged, it must be replaced. It can only be replaced by an authorized person.
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Do not allow children or animals in the boiler area; • Use only quality pellets and no other types of fuel;...
Page 16
Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 The pellet boiler is a combustion device and external surfaces of the boiler can reach higher temperatures during operation.
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 maximum length: 30 mm, moisture content: up to 10 %, combustion value: minimum 16,9 MJ/kg or 4,7 kWh/kg, ash content: below 0,7 % DO NOT use the boiler as an incinerator;...
Page 18
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Figure 10 ATTENTION Be careful that the sealant rope under the edge of combustion chamber is not damaged. If the sealant rope is damaged, contact an authorized service centre.
Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 The combustion chamber must be cleaned after each used pellet container, vacuumed and/or emptied of all impurities remaining after the pellets have burned.
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 6.3. ADDITIONAL MAINTENANCE Your pellet boiler is a heat generator which uses pellets. Therefore, it requires a special type of maintenance by authorized personnel of company BIODOM 27 d.o.o.
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 diameter 30 mm length. Proper operation of the pellet boiler depends on the type and quality of pellets.
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 ATTENTION PELLETS SHOULD NOT BE STORED NEAR THE PELLET BOILER. Keep them at least 1/2 metre away.
Page 23
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Display Function upper display shows boiler status, chosen menu and indicates dosing operation and operation in time programme...
Page 24
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | instructions for use, maintenance and installation | version 1.0 July 2017 version 1.0 July 2017 Button Function ON/OFF button Press and hold to turn the boiler on/off.
Page 25
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017...
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 9.1. BOILER DURING OPERATION The display shows current operation phase (e.g. TestFire, HeatUp etc.). Upper display shows set and actual boiler power alternately every 5 seconds.
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 9.4. TIME PROGRAMME SETTING Press and hold (until TEN displays) MENU button to access time programme menu.
Page 28
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017...
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 9.5. INDICATIONS AND MESSAGES ON DISPLAY Indication on Explanation of message and status of the boiler display The boiler is at a standstill.
Page 30
Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 When water temperature in the boiler, even with minimum power, reaches set temperature, the boiler enters phase COOL FLUID and cools down. The boiler restarts automatically when the water in the boiler cools down under set value.
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 MENU When holding MENU button, menus scroll. To select a certain menu, release the button when it is displayed.
Page 32
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Figure 13: Menu description...
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | instructions for use, maintenance and installation | version 1.0 July 2017 version 1.0 July 2017 INFORMATION REGARDING DESTRUCTION AND DISPOSAL TION REGARDING DESTRUCTION AND DISPOSAL...
• WARRANTY TIME CONDITIONS: Warranty for all Biodom products is valid for 24 months from the date of first start-up, given that a regular maintenance inspection is performed no later than 12 months from the date of start-up. GENERAL WARRANTY CONDITIONS: 1.
Page 42
Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 modifications to the product or tampering with the product, unsuitable or inefficient flue and other reasons not connected to the product, such as incorrect or unsuitable installation;...
Page 43
Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Biodom 27 d.o.o. is not liable for any mistakes in the instructions. We reserve the right to changes without any prior notice.
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Voltage 220 V Current at maximum electrical consumption during boiler operation 1,80 A frequency 50 Hz Maximum consumption of power during boiler operation...
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 __________ INSTRUCTIONS FOR INSTALLERS __________ This part of the instructions is intended solely for installer and contains all key information for...
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 BOILER CONNECTION INSTRUCTIONS The advantage of the pellet boiler Biodom 33 in the easy installation and simple programming.
Page 48
"there cannot be a closing element, which could pre- vent indication of pressure in the boiler in the time of filling"). On the right side of Biodom 33 is a provided DN15 connection for filling release tap. Filling release tap is intended for filling or emptying the heating system and boiler.
Page 49
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Electrical connection of boiler must be performed with a cable (see figure 8, page 14) in ac- •...
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 CONNECTION SCHEMES 18.1. SCHEME NR.1: SYSTEM WITH RADIATOR THERMOSTAT VALVES The room thermostat is not required. System is time leaded by timer (TEN), which is an integral part of the boiler.
Page 51
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Electrical scheme 1...
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 18.2. SCHEME NR.2: SYSTEM WITH RADIATOR THERMOSTAT VALVES AND WITH BOILER The room thermostat is not required. The boiler has priority over heating,...
Page 53
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Electrical scheme 2...
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 18.3. SCHEME NR.3: HEATING WITH MULTIPLE SYSTEMS This type of connection always requires a hydraulic switch. Connection scheme 3...
Page 55
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Electrical scheme 3...
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 __________ INSTRUCTIONS FOR FIRST START-UP __________...
Page 57
Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Biodom 33 is a combustion device for heating with pellets. Benefits of combustion device Biodom 33 lie in advanced technology that enables automatic identification of oxygen contents in air, automatic identification of flue draught and automatic identification of pellet quality.
Page 58
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 "Igni test" – checking ignition, display also changes between igni test and P0 d5, and tempera- •...
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 DECLARATION OF CONFORMITY IZJAVA PROIZVAJALCA O SKLADNOSTI DECLARATION OF CONFORMITY Naziv proizvajalca/Producer: Biodom 27 d.o.o. OIC Hrpelje 4a, 6240 Kozina, Slovenia...
Page 60
Biodom 33 Biodom 33 Biodom 33 Biodom 33 | | | | instructions for use, maintenance and installation | version 1.0 July 2017 Harmonizirani standardi/Harmonised standards: EN ISO 12100-1:2004 and A1:2010 EN ISO 12100-2:2004 and A1:2010 EN 303-5:2012 EN 60204-1:2006 and A1:2009...
Need help?
Do you have a question about the 33 and is the answer not in the manual?
Questions and answers