    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Table of contents: General description ................................3 Completation ..................................3 Technical data ..................................4 Balance keys and indicators ..............................5 Safety principles ..................................7 Principles of user balance treatment ............................7 Preparation to work ................................8 Operation principles ................................8 Operation principles when the scale uses accumulator supply ....................
  • Page 3: General Description

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 1. General description Portable technical scales of BA/LG series are designed for weighing parcels. Double-range option is described in A appendix. All balances are tested in respect of metrology. According to order, balances may be verified or calibrated.
  • Page 4: Technical Data

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 3. Technical data Scale type BA30LG BA60LG BA150LG Maximal load 30kg 200kg 150kg Minima load 200g 400g Reading graduation (d) *10g *10g Verification graduation (e) Accuracy class Working temperature -10 ÷ +40°C Tare range -30kg -60kg -150kg -200kg Weighing time <4s...
  • Page 5: Balance Keys And Indicators

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 4. Balance keys and indicators LCD display version: weighing zero stabilization net weight metrological result indicator indicator data indicator Max= indicator scale keys Keys: switch-on / switch-off (standby),   " tare, menu position confirmation, next digit (when inscribing), ...
  • Page 6 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ LED display version: weight zero stabilization metrological net weight indicator indicator result data indicator Max= scale keys klawisz - switch-on / switch-off (standby),   " - tare, menu position confirmation, next digit (when inscribing),   "...
  • Page 7: Safety Principles

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 5. Safety principles It is necessary to become familiar with safety principles shown below, which are necessary to avoid electric shock and damage of balance or connected devices.  Repairs and necessary adjustments must be performed by qualified personnel only.
  • Page 8: Preparation To Work

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 7. Preparation to work 1. Unpack balance, removing protective foils. 2. During transport overload protection in some scales should be removed. In order to do that, the scale should be put on a side. Under the platform cut clamp bands and remove inserts.
  • Page 9: Operation Principles When The Scale Uses Accumulator Supply

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 9. Operation principles when the scale uses accumulator supply 1. The scale can be supplied ~230V through feeder available with the scale. Moreover a set of accumulators (situated inside the scale) can be used to supply the scale. 2.
  • Page 10: Balance Checking

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Balance checking It is advised to check scale indication accuracy before and after series of measurement using any load with known weight. To check the scale with legal verification use a calibration weight with valid calibration certificate. In case permissible error is exceeded it is advised to contact the nearest service to calibrate the scale.
  • Page 11: Detailed Long Protocol Description

    If scale cooperates with a computer then the computer must have a special program. Dedicated programs are also offered by AXIS. Needed drivers and instructions can be found on the CD supplied with Axis scales. 12.1 Detailed LonG protocol description...
  • Page 12 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________    Scale tarring (calling key press) : ComputerScale: ST CR LF (53h 54h 0Dh 0Ah), ScaleComputer: without response,   Scale zeroing (calling key press):  Computer Scale: SZ CR LF (53h 5Ah 0Dh 0Ah), Scale Computer: without response, ...
  • Page 13: Detailed Epl Protocol Description

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Connection cable WD-1 (connects scale with AXIS printer): SCALE KAFKA PRINTER Setting of internal switches of AXIS printer: SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 SW-7 SW-8 12.2 Detailed EPL protocol description Transmission parameters: 8 bits, 1 stop bit, no parity, baud rate 9600bps, ...
  • Page 14: Start-Up

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Start-up Leave the pan empty, plug a scale to the mains with a ground contact The scale proceeds with following start-up actions: Display test. Meter type displaying Program version The scale is now ready to work. Attention: Displaying program version means positive result of all tests.
  • Page 15: Weighing With Tare

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 14. Weighing with tare   If the scale is not loaded and indicator   doesn’t indicate, press key.   Zero indication and indicator mean that the scale is ready to work. After putting container (package) tare the scale ...
  • Page 16: Scale Menu

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 15. Scale menu All scales except for basic metrological functions: weighing and taring, have many special functions and configuration options. In order to ease using functions user can create his own (personalized) menu. Creating personalized menu: In „out of the box” scale after pressing MENU key only SEtuP option (it contains all configuration options) is available.
  • Page 17: Menu Navigation Rules

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 16. Menu navigation rules Choosing menu options: First position of scale menu shows up after pressing Menu key. The position is displayed for about 7 seconds and then the scale sequentially displays next menu positions. Choosing menu position (option) is done by ...
  • Page 18 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ key working method:  During standard weighing key is used to  switch between net and gross indication. When special function e.g. PCS is turned on, using key enables to go back to standard  weighing mode. Sign „o”...
  • Page 19 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ HR key working method: During normal weighing temporary (5s) readout resolution increase is possible. Return normal indication made automatically. Inscribing numerical values: Inscribing numerical values is needed in some special functions e.g. tArE function requires to inscribe tare values. Keys: 0...
  • Page 20 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Menu diagram: MENU (PCS) (totAL) - personalized function menu created using SEtUP / MEnu - settings SEtUP - creating menu (” “- added to menu) MEnu - choosing product Prod ( ) o ( ) o - choosing user USEr - pieces counting function - actual unit selection...
  • Page 21 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ - serial ports settings settings SErIAL - port - 1 Port-1 - transmission speed (1200, ... ,115 200 bps) bAUd - bits quantity (7 or 8) bItS - parity control PArItY - transmission type (Stab, no StAb, Auto,Cont.,rEMoVE) SEndInG - protocol (LonG, EPL, EPL_A, EPL-d, PEn-01) Prot...
  • Page 22 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ - turn on/off accumulator charging (if the scale is equipped with accumulator) (bAttEry) - automatic turning off - saving accumulator power (as above) (AUto OFF) - scale start zero inscribing (factory zero) (ZEro) - restore default settings for all options dEFAULt - options only for service SErVICE...
  • Page 23: Scale Setup (Setup)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Scale setup (SEtUP) SEtUP contains all options used for setting scale work mode: MEnu – creating personalized user menu  CALIb – scale sensitivity calibration  AutoZEro(ing) – self-maintaining zero indication  (unloaded scale) UnIt – weight unit selection ...
  • Page 24: Scale Calibration (Calib)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 17.1 Scale calibration (CALIb) Press MENU key.   Press key when CALIb function appears. The following options will be displayed: -CAL on – calibration with external recommended standard of mass (see technical data). -CAL StP – calibration with external weight, confirmation of succesive steps - MENU key, out –...
  • Page 25: Autozeroing Function (Autozer)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 17.2 Autozeroing function (AutoZEr) When the function is activated, the scale automatically ensures stable zero indication if the pan is empty or if zero indication was   acquired by pressing key. To turn on the function use MENU key and using ...
  • Page 26: Weight Unit Selection (Unit)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 17.3 Weight unit selection (UnIt) The function allows selecting weighing unit: - CarAt (1 ct= 0,2 g) - carat, - MGrAM (1mg=0,001g) milligram, - KGrAM (1kg=1000g) kilogram, - Pound (1 lb=453,592374g) English pound, - OunCE (1oz=28,349523g) - ounce, - OunCEt(1ozt=31,1034763g) pharmaceutical ounce, - GrAIn (1gr=0,06479891g) - grain - PennYW (1dwt=1,55517384g) jewellery mass unit,...
  • Page 27: Serial Port Parameters Setting (Serial)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 17.4 Serial port parameters setting (SErIAL) function allows setting independently communication parameters of both of serial ports Port-1 and Port-2 (executed in RS232C, RS485, USB or LAN standard): - transfer protocol (Prot): LonG – cooperation with printer or computer, EPL –...
  • Page 28: Printout Configuration (Print)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 17.5 Printout configuration (PrInt) Function is used for printing additional information stored in scale memory, weighed product identification data and scale operator id. That information is inscribed using scale keys or scanner. After entering selected port (scale can have two ports) user may activate printout positions: - HEAdEr –...
  • Page 29 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Sample printout during normal weighing (all printout positions deactivated): 20.07 kg 20.04 kg 20.04 kg Sample printout during normal weighing with clock option (all printout positions deactivated): 20.07 kg 2012-11-08 10:01 20.04 kg 2012-11-08 10:01 20.04 kg 2012-11-08 10:01 Sample printout during normal weighing ( some printout positions activated): BA30 MAX: 30kg e=d=0.01kg...
  • Page 30: Setting Backlight Function (B_Light)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 17.6 Setting backlight function (b_LIGHt) The function is used for choosing the work mode of scale display backlight: - b_L OFF – switch backlight off, - b_L on – switch backlight permanently on, - b_L ECO – switch off after 30 seconds of inactivity (no load changes and no key operation), - b_L bAt –...
  • Page 31: Analog Out Configuration (Analog)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 17.7 Analog out configuration (AnALoG) This option enables to set-up analog out (4-20mA or 0-10V) working method used e.g. in PLC regulators: AnG rnG – inscribing Max value AnG CFG – working mode configuration (PLUS – workmode for only positive values, MinuS – only for negative values, both –...
  • Page 32: Entering Reference Zero Value (Zero)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 17.8 Entering reference zero value (ZErO) Note: This function is enabled in non-legalized scales only. ZEr0 function allows entering new value of reference zero (value referred to empty pan) without need of contacting with authorised service centre. Press MENU key.
  • Page 33: Special Functions Description

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 18. Special functions description All scales besides basic metrological functions: weighing and taring, have a set of special functions. Depending on meter type functions set differs. Below a list of functions available in standard ME-01 type meters: Products data base (Prod), ...
  • Page 34: Products And Users Database (Prod I User)

    This way created database, saved in *.csv extension with semicolons can be send to scale using Scale Database software and scale’s serial interface. Scale Database is available on our webpage www.axis.pl/en. Database and possibility to cooperate with external devices: printer, label printer, barcode reader and computer enables to built product identification and product archiving systems.
  • Page 35 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Inscribing data to base Prod and USEr options enables adding and deleting product and user data. For products database available options are: - Prod Id – searching for product in database by inscribing (or scanning) id number or barcode, - ProdCLr (shows up if product was selected earlier) –...
  • Page 36 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Users database is edited by similar function named USEr and consists of several options: - USEr Id – user identification number, - USErCLr (shows up if user was selected earlier) – turns off actual user selection, - USEr nA – user name (inscribed from PC or scanner), - Prn_U –...
  • Page 37 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Weighing results and data transmission from scale to computer or to printer To fully use database capabilities other options must also be used: SeriaL, LabeL (for label printer) and Print. Serial option enables to select proper transmission protocol for each port. Thereby label printer can work independently.
  • Page 38: Pieces Counting Function (Pcs)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 18.2 Pieces counting function (PCS) This function enables to count identical pieces, e.g. turnbuckles or buttons. A measurement is performed in two phases: - first phase - single piece weight calculation on the basis of defined pieces amount (5, 10, 20, 50, 100, 200 or 500 pieces), - second phase –...
  • Page 39: Percentage Weighing Function (Perc)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 18.3 Percentage weighing function (PErC) 100% This function allows displaying weighing result in percents. A measurement is performed in two phases: - first phase – weighing a reference sample (100%), - second phase – measuring specific sample as a percentage of the reference sample.
  • Page 40: Label Choosing Function (Label)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 18.4 Label choosing function (LAbEL) This function is used in scale with EPL (SErIAL function) data protocol. This protocol enables label printout with actual scale indication and chosen data from PrInt special function (variable data), for example date and time.
  • Page 41: Weighing Animals Function (Loc)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 18.5 Weighing animals function (LOC) The function allows weighing animal moving on the scale. Press MENU key.   When LOC function is displayed press key. following options appear display successively: - LOC oFF – leave the function, - LOC on –...
  • Page 42: Maximum Value Indication Function (Up)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 18.6 Maximum value indication function (UP) This function allows holding maximum (or minimum) value that is indicating at the moment. Before measurement scale should be tared. Function has following options: -UP oFF – function off, -HIGH – holding maximum value, -LOW –...
  • Page 43: Force Measuring Function (Newton)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 18.7 Force measuring function (nEWton) Function activation causes displaying result in force units (N). Press MENU key.   Using key choose NEWto function. Function has several options: - nEW oFF – function off, - nEW on – measurement in Newtons, - ArM –...
  • Page 44: Total Weight Function (Total)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 18.8 Total weight function (totAL) The function allows calculating total weight for series of measurements, which can be greater than scale capacity. It allows calculating total weight as well as average value. Press MENU key.   When totAL is displayed press key.
  • Page 45 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ To leave the function with clearing total register, select totAL function from menu and choose tot oFF option. Scale prints the communicate informing about clearing registers. The form of standard receipt (measurement number and weight) after each measurement: Print configuration option (chapter 17.5) enables to extend standard receipt form.
  • Page 46: Checkweighing Function (Thr)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 18.9 Checkweighing function (thr) This function allows comparing weighing result with two programmed reference values: lower and upper threshold. Comparison result is signalled with indicators (MIN, OK, MAX) and sound signal generated when threshold values are exceeded. If comparison result is: - smaller than zero threshold –...
  • Page 47 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Operation sequence:   Press MENU key and choose thr pressing key. The following options are displayed successively: - thr oFF – deactivate the function, - thr on – activate the function, - thr Prn – check last threshold values (press key several times), - thr CFG –...
  • Page 48 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Relays connection diagram: Imax < 25mA Relays output is the open collector transoptor output with load capacity 25mA / 24V. Transmitter inputs must be protected with diodes, e.g. 1N4148. It is advised to use MS3K/P electronic board (sold separately), consisting of RM96P transmitters, with DC24V input voltage and AC250V, 3A output.
  • Page 49: Setting Date And Time Function (Date)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 18.10 Setting date and time function (dAtE) The function allows setting current date and time of scale internal clock and mode of its use. The function has the following options: - dAt oFF – deactivate date and time during printout of current weighing result, - dAt on –...
  • Page 50: Radio Communication Channel Choice Function (Rf Chn)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 18.11 Radio communication channel choice function (rF CHn) Function enables choosing radio communication channel between the scale and a pilot. In scale and in pilot the same radio channels must be chosen. Function should be used when communication is disturbed by other devices that use the same communication channel.
  • Page 51: Charging Accumulators Function (Battery)- Option

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 18.12 Charging accumulators function (bAttErY)- option bAttErY function allows switching on or off charging accumulators during work with feeder and checking their power level. The function has the following options: - bAt OFF – charging off (option required if ordinary batteries are used !!!), - bAt on –...
  • Page 52: Automatic Switching Off The Scale Function (Autooff)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 18.13 Automatic switching off the scale function (AutoOFF) The function is helpful in scales supplied from accumulators. The function causes scale to switch off automatically. Press MENU key.   When AutoOFF is displayed press key. The following options appear successively on display: - AOF oFF –...
  • Page 53: Statistical Calculations Function (Stat)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 18.14 Statistical calculations function (StAt) This function evaluates from series of measurements (max 1000) statistical parameters of weighting process. Adding successively measurements to register is automatic and it occur after the scale is loaded and its indications stabilize. After each loading printout is made with: number of measurements, result, date and time (if clock is installed and the function is activated).
  • Page 54 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Order of operations: Press MENU key.   When StAt is displayed press key. The following options are displayed: - StA Prn – monitoring and printout of statistical data, - StA oFF – deactivate function, - StA –...
  • Page 55 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Pressing key printouts estimated values and histogram : Nominal - nominal value, Tolerance - accepted value in percentage. N - number of sample IN TOL. – number of samples in toleranc -TOL – amount of measurements under allowable lower value +TOL –...
  • Page 56: Paperweight Calculation (Pap)

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 18.15 Paperweight calculation (PAP) This function enables to calculate paperweight of 1m of paper basing on samples of known area. For quick access, the function is accessible directly by pressing MENU key. The balance must be tared just before the measurement.
  • Page 57: Maintenance And Repairs Of Small Defects

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 19. Maintenance and repairs of small defects 1. The scale should be kept clean. The balance must be kept clean and protected from dust, and aggressive liquids. In order to clean it is recommended to wipe the scale with cloth soaked in soapy water and then dry.
  • Page 58: Declaration Of Conformity

    INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Declaration of Conformity AXIS Spółka z o.o. 80-125 Gdańsk, ul. Kartuska 375B confirm with all responsibility that scales: BA30LG, BA60LG, BA150LG marked with CE mark comply with the following: 1. Directive 2004/108/EWG (electromagnetic compatibility) and harmonized norms:...
  • Page 59 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Appendix A Information’s concerning double-range scale (options) 1. General description Double-range scale’s have capability of work with greatest accuracy in bottom measuring range part. Weighing of smallest mass is more precise. This type of scale’s have two measurement range: - 50 % of maximum load (mostly), –...
  • Page 60 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ 2. Double-range scales parameters B30LGZ B60LGZ B150LGZ Scale type Maximal load (Max /Max 15/30kg 30/60kg 60/150kg Minima load 100g 200g 400g Reading graduation (d 5/10g 10/20g 20/50g Verification graduation 5/10g 10/20g 20/50g Accuracy class Tare range -30kg -60kg -150kg EC verification...
  • Page 61 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________ Notes...
  • Page 62 INSTRUCTION MANUAL _____________________________________________________________________________________________________________________...

This manual is also suitable for:

B30lgzB60lgzB150lgzBaLgBa30lg ... Show all

Table of Contents