Advertisement

Quick Links

USER MANUAL
B/P SERIES
FILE: 2010-10-BP-113 B-50_0 GB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the B/P Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Axis B/P Series

  • Page 1 USER MANUAL B/P SERIES FILE: 2010-10-BP-113 B-50_0 GB...
  • Page 2: Table Of Contents

    USER MANUAL _____________________________________________________________________________________________________________________ Table of contents: General description....................4 Completation......................4 Technical data ......................5 Balance keys and indicators ..................6 Security principles......................7 Environment protection ....................7 Preparation to work....................8 Start-up........................9 General rules ......................10 Balance checking..................... 11 Scale adjustment ..................... 11 Connecting a computer or a printer (optional)............12 Basic function ......................
  • Page 3: User Manual

    USER MANUAL _____________________________________________________________________________________________________________________ 14.15 Total weight function (totAL)..................36 14.16 Function for setting date and time (dAtE) ..............38 14.17 Function for selecting label number (LAbEL)............39 14.18 External calibration (CALIb)..................40 14.19 Setting time of stabilization function (Stb)..............41 14.20 Entering reference zero function (Zero)..............
  • Page 4: General Description

    Renewing of scale legal verification is required when protective seal is violated or after period of 3 years starting from 1 December of year when first legal verification was performed. In order to renew legal verification please contact authorized service of AXIS. NACE classification: 29.24.23. Certificates: EC Type...
  • Page 5: Technical Data

    USER MANUAL _____________________________________________________________________________________________________________________ 3. Technical data Scale type B30P B50P Max load 30kg 50kg Min load 200g 400kg Readout graduation (d) Verification graduation (e) Tare range -30kg -50kg Accuracy class Working temperature -10 ÷ +40°C Weighing time <3s Pan dimensions 400x400mm 390x390mm Scale dimensions...
  • Page 6: Balance Keys And Indicators

    USER MANUAL _____________________________________________________________________________________________________________________ 4. Balance keys and indicators klawisz - włącznik / wyłącznik (standby), → ← klawisz - tarowanie (wpisywanie masy opakowania odejmowanej od masy waŜonej), klawisz - wskazanie masy brutto, klawisz → ← - zerowanie, klawisz MENU - menu funkcji specjalnych, klawisz - wydruk wyniku, klawisz...
  • Page 7: Security Principles

    USER MANUAL _____________________________________________________________________________________________________________________ 5. Security principles To avoid electrical shock or damage of the scale or connected peripheral devices, it is necessary to follow the security rules below. • All repairs and necessary regulations can be made by authorised personnel only.
  • Page 8: Preparation To Work

    USER MANUAL _____________________________________________________________________________________________________________________ 7. Preparation to work 1. Take the scale out of the package removing protective foils. 2. Remove the pan and remove protection elements from below the pan. 3. Place the scale on a stable ground not affected by mechanical vibrations and airflows.
  • Page 9: Start-Up

    USER MANUAL _____________________________________________________________________________________________________________________ 8. Start-up Leave the pan empty, plug the feeder to the mains (~230V/50Hz) and plug the feeder connector to the 12V power socket at the back of the scale. The scale proceeds with following start-up actions: Display test. Basic electronic components tests: C1, C-2, ...
  • Page 10: General Rules

    USER MANUAL _____________________________________________________________________________________________________________________ 9. General rules 1. Before each measurement make sure that zero indicator is displayed. If zero indicator does not displayed or “----“ communicate appears, press →0← key and wait until zero indication and zero indicator appears. 2. The scale is equipped with a tare equal to its range. To tare the scale press →T←...
  • Page 11: Balance Checking

    USER MANUAL _____________________________________________________________________________________________________________________ Balance checking It is advised to check scale indication accuracy before and after series of measurement using any load with known weight. To check the scale with legal verification use a calibration weight with valid calibration certificate. In case permissible error is exceeded it is advised to contact the nearest service to calibrate the scale.
  • Page 12: Connecting A Computer Or A Printer (Optional)

    In special features scale can be equipped in second RS232 interface for additional functions, ex. continues transmit of indicate to second display. Computer must have a special program for cooperation with a data from a scale. This programs are procurement by Axis.
  • Page 13 02h scale number command. To log the scale out use 03h command. For example: Using a program to test RS232 interface ( program is available in www.axis.pl / programy komputerowe ) for scale number 1 please write: $0201 to log in, then SI, and write: $03 to close communication.
  • Page 14 USER MANUAL _____________________________________________________________________________________________________________________ Scale →Computer: without response, Entering to special function menu (calling MENU key press): Computer→ Scale: S F CR LF (53h 46h 0Dh 0Ah), Scale →Computer: without response, Setting low threshold value (option): Computer→ Scale: S L D1...DN CR LF (53h 4Ch D1...DN 0Dh 0Ah) D1...DN –...
  • Page 15 USER MANUAL _____________________________________________________________________________________________________________________ Protocol ELTRON description Communication parameters: 8bits, 1stop, no parity, 9600bps, After use key scale send: Scale→Label printer : EPL-2 language instruction to initialize print of label: - control instruction FR"0001" - number of labels - starting instruction hh:mm - 5 signs: hours:minutes yyyy.mm.dd...
  • Page 16: Basic Function

    USER MANUAL _____________________________________________________________________________________________________________________ Basic function To make clear how to manage with each function, in further part of instruction descriptions are replaced with pictures. - put a load on the pan - remove the load from the pan 2.30 press the key when indication is displayed - forced change - automatic change...
  • Page 17: Weighing With Tare

    USER MANUAL _____________________________________________________________________________________________________________________ 13.2 Weighing with tare The scale is equipped with tare equal 2.30 to its range. Joint value tare and mass net can not 0.00 cross a maximum of scale. To display gross weight press B/G key. 40.01 Note: Press B/G key to return to net weight indication.
  • Page 18: Special Function Describes

    USER MANUAL _____________________________________________________________________________________________________________________ Special function describes List of available functions: menu customization function (ACtIV), removal of all function from menu (dEFAUL). autozeroing function (AutoZE), pieces counting function (PCS), function for setting serial port working (PrInt) function for setting serial port (Port) entering tare function (tArE) recipe weighing function (rECIPE), weighing large animals function (LOC)
  • Page 19: Menu Customization Function (Activ And Defaul)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.1 Menu customization function (ACtIV and dEFAUL) Among available user functions it is 0.00 possible to select these, which should be displayed after pressing MENU key. It allows avoiding displaying whole list of available functions, which makes ACtIV operation time longer.
  • Page 20: Autozeroing Function (Autoze)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.2 Autozeroing function (AutoZE) When F..-Aut function is activated, 0.01 the scale automatically ensures stable zero indication if the pan is empty or if zero indication was acquired by → ← pressing key. AutoZE To leave the function press MENU →...
  • Page 21: Pieces Counting (Pcs)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.3 Pieces counting (PCS) This function enables to count identical pieces, e.g. turnbuckles or 0.00 buttons. A measurement is performed in two phases: - first phase - single piece weight calculation on the basis of defined 23.40 pieces amount (5, 10, 20, 50, 100, 200 or 500 pieces), - second phase –...
  • Page 22: Printer Cooperation Settings (Print)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.4 Printer cooperation settings (PrInt) Activate the function for automatic 0.00 serial port working mode (cooperation with a printer. After activation the scale prints a header. Weighing result with PrInt a successive measurement number is printed automatically after result stabilisation (without using key).
  • Page 23: Serial Port Parameters Setting (Port)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.5 Serial port parameters setting (Port) 0.00 The function enables to set the following transmission parameters (standard parameters underlined: Port - transmission protocol (Prot): LonG - printer, ELtron – label printer, - transmission speed (bAud: 1200, Port-0 4800, 9600, ...), - the number of bits in a byte (bit: 7, Port-1...
  • Page 24: Constant Tare (Tare)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.6 Constant tare (tArE) This function enables to measure gross weight of a sample placed in a container of a known weigh value (stored in the memory) and to display calculated net weight → ← of the sample. Tare value is recalled from the memory with key when the pan is empty.
  • Page 25 USER MANUAL _____________________________________________________________________________________________________________________ Weighing with constant tare: When tAr function is activated, press -1.70 → ← key to zero the indication and to recall tare value from the memory. Tare value is displayed with ”-” sign. 10.00 enables instant switching between net and gross weight.
  • Page 26: Average Calculation Function (Averag)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.7 Average calculation function (AVErAG) The function allows for calculating average value of performed measurement series. During series of measurements successive results are registered automatically when scale indication is stabilised. Press MENU key and select AUErAG 0.00 →...
  • Page 27: Recipe Weighing Function (Recipe)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.8 Recipe weighing function (RECIPE) This function allows for separate 0.00 MENU weighing of several ingredients in one container with a possibility of control total weight of all weighed rECIPE components. The function has the following options: - rECI-0 –...
  • Page 28: Percentage Weighing Function (Perc)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.9 Percentage weighing function (PErC) This function allows displaying weighing result in percents. A measurement is performed in two phases: 0.00 - first phase – weighing a reference sample (100%), 100% - second phase – measuring specific sample percentage 1.70...
  • Page 29: Anti-Disturbance Filter Function (Filter)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.10 Anti-disturbance filter function (FILtEr) This function allows using digital filter 0.00 with selected intensivity during weighing. Filter reduces the influence of mechanical vibrations (air blasts, FILtEr base vibrations) on measurement result. Press MENU key and select FILtEr →...
  • Page 30: Function For Maximum Value Indication (Up)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.11 Function for maximum value indication (UP) This function allows holding on display maximum value shown by the scale in a while. Before measurement scale should be 0.00 tared. After using MENU key and selecting UP function the highest mass result will be hold on display.
  • Page 31: Force Measuring Function (Newto)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.12 Force measuring function (nEWto) Function activation causes displaying result in force units (N). Press MENU key. nEWto → ← Using key choose NEWto function, and then NEW-1. Note: 1N≈0,1019kg nEW -0 nEW -1 0.000...
  • Page 32: Function For Weighing Large Animals (Loc)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.13 Function for weighing large animals (LOC) The function allows weighing animal moving on the scale. Press MENU key. 0.00 MENU When LOC function is displayed press → ← key. The following options appear on display successively: L OC - LOC-0 –...
  • Page 33: Checkweighing Function (Thr)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.14 Checkweighing function (thr) This function allows comparing weighing result with two programmed reference values: lower and upper threshold. Comparison result is signalled with indicators (MIN, OK, MAX) and sound signal generated when threshold values are exceeded. If comparison result is: - smaller than lower threshold –...
  • Page 34 USER MANUAL _____________________________________________________________________________________________________________________ Relays connection diagram: Relays output is the open collector transoptor output with load capacity 100mA / 24V. Transmitter inputs must be protected with diodes, e.g. 1N4148. It is advised to use MS3K/P electronic board (sold separately), consisting of RM96P transmitters, with DC24V input voltage and AC250V, 3A output.
  • Page 35 USER MANUAL _____________________________________________________________________________________________________________________ Operation sequence: Press MENU key and choose thr 0.00 → ← pressing key. The following options are displayed successively: - thr-0 – deactivate the function, - thr-1 – activate the function, - thr-P – check last threshold values (press key several times), thr -0...
  • Page 36: Total Weight Function (Total)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.15 Total weight function (totAL) The function allows calculating total weight for series of measurements, which can be grater than scale capacity. It allows calculating total weight as well as average value. Press MENU key. 0.00 MENU →...
  • Page 37 USER MANUAL _____________________________________________________________________________________________________________________ To leave the function with clearing total register, select total function from menu and choose tot-0 option. When It will cause the scale prints the communicate informing about clearing registers The form of receipt after each measurement: Date: Time.
  • Page 38: Function For Setting Date And Time (Date)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.16 Function for setting date and time (dAtE) The function allows setting current 0.00 date and time of scale internal clock and mode of its use. The function has the following dAtE options: - dAt-0 – deactivate date and time during printout of current weighing dAt- 0 result,...
  • Page 39: Function For Selecting Label Number (Label)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.17 Function for selecting label number (LAbEL) The function appears in scales with ELTRON data transmission protocol. This protocol allows printing scale indication and optionally date and time on label printer, as variable texts. Other data, e.g. company address, product name, its bar code can appear on label as constant fields.
  • Page 40: External Calibration (Calib)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.18 External calibration (CALIb) Note: This function is enabled in non legalized scales only. Calibration of sensitivity should be make when aaccuracy of scale is not satisfactory. Could use standard mass equal of maximum range of scale (Max). Operation sequence: Press MENU key to call functions 0.00...
  • Page 41: Setting Time Of Stabilization Function (Stb)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.19 Setting time of stabilization function (Stb) The function allows changing stabilisation time of scale indication and connected with it the time of waiting for starting result printout on a printer connected to the scale. Press MENU key. 0.00 →...
  • Page 42: Entering Reference Zero Function (Zero)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.20 Entering reference zero function (Zero) Note: This function is enabled in non legalized scales only. ZER function allows entering new value of reference zero (value referred to empty pan) without need of contacting with authorised service centre. Press MENU key.
  • Page 43: Automatic Switching Off The Scale Function (Autoof)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.21 Automatic switching off the scale function (AutoOF) The function is helpful in scales supplied from accumulator. The function causes scale to switch off automatically after c.a. 10 minutes of not using it. Switching function on causes last entered zero and tare values are remembered in scale memory.
  • Page 44: Density Determining Function (Densit)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.22 Density determining function (dEnSIt) The function allows determining 0.00 solid density basing on its weight in the air and in liquid of known density using the formula below: dEnSIt g=  * g liquid dEn -1 where: m -weight in the air - weight in liquid...
  • Page 45 USER MANUAL _____________________________________________________________________________________________________________________ If a printer is connected to the scale, printout of solid density measurement results will be performed in the following form: Date: ... Time..MEASUREMENT No. = WEIGHT in air WEIGHT in liquid HANGER WEIGHT LOAD DENSITY g/cm LIQUID DENSITY g/cm...
  • Page 46: Calculator For Good Packaging Control (Tp)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.23 Calculator for good packaging control (tP) Note: This function is enable for special orders substitutable with other functions. The function allows performing not destroying control of 60, 100 or 160 samples of packed goods. Calculation formula complies with the description of reference method described in act of law from 26.07.2001 (with later changes).
  • Page 47 USER MANUAL _____________________________________________________________________________________________________________________ [Entering product data] → ← 3. Press key when "F..-2" is displayed. The following options appear successively on display: "Cod"- product code [6 digits], "n" - batch size, "out" - exit, → ← 4. Press key when "Cod" is displayed. Previously entered product code will be displayed one by one with "out"...
  • Page 48 USER MANUAL _____________________________________________________________________________________________________________________ PLACE OF Successive results will be printed in table CONTROL: ......... with indication of their values using "*" character Date: Time: ... referred to limit values. CONTROL NO.: ........ SCALE TYPE FACTORY NO. BATCH SIZE VALUE Qn VALUE Qn-T1 VALUE Qn-2T1 Qn-2T1...
  • Page 49: Statistical Calculations Function (Stat)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.24 Statistical calculations function (StAt) Attention: Function is available on demand and it replaces other special functions. This function evaluates from series of measurements (max 500) statistical parameters of weighting process. Adding successively measurements to register is automatic and it occur after the scale is loaded and its indications stabilize.
  • Page 50 USER MANUAL _____________________________________________________________________________________________________________________ Data: Hour..This will cause printout of calculated statistics and SAMPLES TOTAL MASS histogram : AVER MASS MIN MASS MAX MASS = LSL - allowable lower value, MAX – MIN USL - allowable upper value, A, B, C, .. – measurement intervals, SREL ...
  • Page 51: Paperweight Calculation (Pap)

    USER MANUAL _____________________________________________________________________________________________________________________ 14.25 Paperweight calculation (PAP) Note: This function is enable for special orders substitutable with other functions. This function enables to calculate paperweight of 1m of paper basing on samples of known area. For quick access, the function is accessible directly by pressing MENU key.
  • Page 52: Maintenance And Small Repairs

    USER MANUAL _____________________________________________________________________________________________________________________ 15. Maintenance and small repairs 1. Keep the balance clean. 2. Take care, for during the operation some impurities may enter under balance base and into sensors vicinity. In case of impurities finding remove them. 3. In case of improper operation due to short power failure, switch off the balance by unplugging the power cable from the socket, and plug it again after a few seconds.
  • Page 53: Declaration Of Conformity

    USER MANUAL _____________________________________________________________________________________________________________________ Declaration of Conformity AXIS Spółka z o.o. 80-125 Gdańsk, ul.Kartuska 375B declare with full responsibility, that the balances: B30P, B50P marked with CE mark are consistent with: 1. Standard PN-EN 61010-1:2004 Safety requirements for electrical equipment for measurement, control and laboratory use.

This manual is also suitable for:

B30pB50p

Table of Contents