Hall Sensor Troubleshooting - Nokia 6500 SLIDE RM-240 Service Manual

Mobile terminal
Hide thumbs Also See for 6500 SLIDE RM-240:
Table of Contents

Advertisement

RM-240
BB Troubleshooting and Manual Tuning Guide

Hall sensor troubleshooting

Troubleshooting flow
1 When the phone is on and has been closed for approx. 1 minute - open the phone. The phone shall be
active (Menu shown).
2 Check the voltage at R2407 (the hall sensors and the resistor forms a NOR gate). It should be approx. 1.8V
when the phone is closed. When it approx. 15mm open, hall sensor 1 should be active an drop the voltage
to 0V. At about 22mm of opening the hall sensor 2 shall be active low and remain so until the phone is
fully open at 30mm. Replace faulty hall sensors.
3 If the fault remains - replace the PWB.
4 If the problem remains - check the magnet.
Issue 1
COMPANY CONFIDENTIAL
Copyright © 2007 Nokia. All rights reserved.
Page 3 –27