Calibrating The Spray Pro Monitor - Toro 41163 Operator's Manual

Turf sprayer
Table of Contents

Advertisement

• App. Rate
Displays the application rate in US gallons per acre
(US), liters pre hectare (SI), or US gallons per 1000 sq
ft (TURF).
• Total Volume
Displays the total volume in US gallons (US and
TURF) or liters (SI) that you have applied since you last
pressed the [RESET] button for this setting.
• Sub Volume
Displays the total volume in US gallons (US and
TURF) or liters (SI) that you have applied since you last
pressed the [RESET] button for this setting, without
affecting the Total Volume display. If you press
[RESET], the Sub Area also resets.
• Distance
Displays the distance you have traveled in feet (US and
TURF) or meters (SI) since you last pressed the
[RESET] button for this setting.
• Total area
Displays the total acres (US), hectares (SI), or sq feet
(TURF) that you have covered since you last pressed
the [RESET] button for this setting.
• Sub Area
Displays the total acres (US), hectares (SI), or sq feet
(TURF) that you have covered since you last pressed
the [RESET] button for this setting, without affecting
the Total Area display. If you press [RESET], the Sub
Volume also resets.
Buttons
The monitor has the following buttons:
• [RESET]
Resets the Total Volume, Sub Volume, Distance, Total
Area, and Sub Area display settings to 0.
• [CAL]
Used to enter and exit the calibration mode.
• [–]
Reduces values displayed on the screen during
calibration.
• [+]
Increases values displayed on the screen during
calibration.
Calibrating the Spray Pro
Monitor
The Spray Pro monitor has a calibration mode that allows
you to change various settings to customize the display and
calibrate the monitor to your needs. You can calibrate or
change the following settings:
• Boom Width
• Units of Measure
• Speed
• Flowmeter
Setting the Boom Width
The default settings for the boom widths are 80 inches
(200 cm) for the right and left booms and 60 (150 cm) for
the center boom. This is based on 4 nozzles on the right
and left booms and 3 on the center boom all spaced
20 inches (50.8 cm) apart. If you change the spacing of the
nozzles, you should change the boom width to reflect your
changes as follows:
1. Stop the sprayer and set the parking brake.
2. Set the master boom switch to the Off position. The
monitor displays "HOLD."
3. Press and hold [CAL] until the monitor displays "CAL
HOLD" and the red light on the monitor illuminates.
4. Turn the selection dial to the Total Area position.
5. Use the [+] or [–] buttons to select the boom for which
you wish to change the width, where 1 is the left boom,
2 is the center boom, and 3 is the right boom.
6. Turn the selection dial to the Sub Area position.
7. Use the [+] or [–] buttons to change the boom width as
needed.
8. Repeat steps 4 through 7 for the other booms as needed.
9. Press [CAL] until the red light turns off. You can also
exit calibration mode by driving the sprayer.
Setting the Units of Measure
The default setting for the units of measure is US. You can
also change the units to SI (metric) or TURF.
1. Stop the sprayer and set the parking brake.
2. Set the master boom switch to the Off position. The
monitor displays "HOLD."
3. Press and hold [CAL] until the monitor displays "CAL
HOLD" and the red light on the monitor illuminates.
4. Turn the selection dial to the Units of Measure position.
24

Advertisement

Table of Contents
loading

This manual is also suitable for:

41165Multi-pro 1250

Table of Contents