ACU-RITE 00502 Instruction Manual

ACU-RITE 00502 Instruction Manual

Professional weather center

Advertisement

Quick Links

CONTENTS
Package Contents .................. 2
Product Registration ............... 2
Back of Display Unit............... 6
Setup .................................... 7
5-in-1 Sensor Setup ................ 7
Display Unit Setup ................. 8
Set the Time & Date ............... 9
Measurement Units ...............10
Questions?
(877) 221-1252 or visit www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Professional Weather Center
Placement Guidelines ............ 11
Programmable Alarms...........13
Troubleshooting ....................15
Care & Maintenance.............17
Calibration ...........................17
Specifications........................19
FCC Information ...................19
Customer Support ................ 20
Warranty............................. 20
Contact Customer Support at
Instruction Manual
model 00502

Advertisement

Table of Contents
loading

Summary of Contents for ACU-RITE 00502

  • Page 1: Table Of Contents

    Instruction Manual Professional Weather Center model 00502 CONTENTS Unpacking Instructions ... 2 Placement Guidelines .... 11 Package Contents ....2 5-in-1 Sensor Installation..12 Product Registration ....2 Using the Weather Center ..13 Features & Benefits: 5-in-1..3 Programmable Alarms...13 Features & Benefits: Display..4 Troubleshooting ....15...
  • Page 2: Unpacking Instructions

    Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference. Unpacking Instructions Remove the protective film that is applied to the LCD screen prior to using this product.
  • Page 3: Features & Benefits: 5-In-1

    Features & Benefits 3 4 5 5-IN-1 SENSOR 1. Rainfall Collector Funnel 5. Temperature & Humidity Sensors (internal) 2. Solar Cell Panel Converts sunlight into power to run 6. Mounting Bracket internal aspirating fan. 7. Wind Speed Anemometer Internal Aspirating Fan (not shown) 8.
  • Page 4: Features & Benefits: Display

    Features & Benefits Display...
  • Page 5 1. Peak Wind Speed 19. Record Low Highest speed from past 60 minutes. Shown for current category selected on the display (#15). 2. Wind Speed Alarm On Indicator 20. Clear Button 3. Average Wind Speed Deletes record low (#19) shown. of all speeds from past 2 minutes.
  • Page 6: Back Of Display Unit

    Back of Display Unit BACK OF DISPLAY UNIT 5. Clear Today Clears data recorded since 12:00am. 1. Backlight Dimmer Switch 6. Reset Adjusts display backlight settings: Full reset to factory defaults. Off, low, medium, high 7. Clear All 2. Integrated Hang Hole Clears all data recorded.
  • Page 7: Setup

    SETUP 5-in-1 Sensor Setup Set the A-B-C Switch cause alkaline batteries to function improperly. Use lithium batteries in Locate the A-B-C switch inside the the 5-in-1 sensor for temperatures battery compartment. Set the A-B-C below -4ºF / -20ºC. switch to A, B or C. You must select 1.
  • Page 8: Display Unit Setup

    Display Unit Setup The display unit operates with batteries and/or power adapter. Regardless of the power source, it is recommended that batteries always be installed to ensure continuous operation (and retain records) in case of a power outage. Set the A-B-C Switch Install or Replace Backup Batteries (optional) The A-B-C switch is located inside...
  • Page 9: Set The Time & Date

    Set the Time & Date The clock and calendar are utilized to time stamp history records and other data, so it is important to set the time and date soon after you power on the display unit. Set the Time 1.
  • Page 10: Measurement Units

    Select Measurement Units To select between standard units (mph, ºF, etc.) or metric units (kph, ºC, etc.): 1. Press the up or down arrow buttons until “SET UNITS?” is displayed on the Selectable Category part of the display unit. 2. Press the “ ”...
  • Page 11: Placement Guidelines

    Placement for Maximum Accuracy AcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display unit and the sensor are critical to the accuracy and performance of this product. Display Unit Placement Place the display unit in a dry area free of dirt and dust. To ensure accurate temperature measurement, place out of direct sunlight and away from heat sources or vents.
  • Page 12: 5-In-1 Sensor Installation

    5-in-1 Sensor Installation Guidelines INSTALLATION HEIGHT Mount the sensor at a minimum height of 5 feet (1.5 meters) off the ground, in an open area. Higher is better for wind measurements - the National Weather Service recommends 33 feet high! MOUNTING OPTIONS The included mounting bracket is designed to screw directly onto wooden posts or surfaces that are 2”x4”...
  • Page 13: Using The Weather Center

    OPERATION Using the Professional Weather Center Learning Mode Self-Calibrating Forecasting use a unique algorithm to analyze changes in pressure over a time period (called Learning Mode) to determine your altitude. After 14 days, the Learning Mode icon disappears from the display screen. At this point, the self-calibrated pressure is tuned in to your location and the unit is ready for superior weather prediction.
  • Page 14 Set a Weather Alarm 1. Choose the weather category for which you wish to set an alarm by pressing the up or down arrow buttons until the category is displayed on the Selectable Category part of the display unit. 2. To program a value (only applies to alarms that require a value), press AND HOLD the “...
  • Page 15: Troubleshooting

    Troubleshooting Problem Possible Solution • Relocate the display unit and/or the 5-in-1 sensor. The units must be within 330 ft (100 m) of each other. • Make sure both units are placed at least 3 feet (.9 m) away from electronics that may interfere with the wireless communication (such as TVs, microwaves, computers, etc).
  • Page 16 Troubleshooting Problem Possible Solution • Make sure both the display unit and sensor are placed away from heat sources or vents (see p.11). • Make sure both units are positioned away from Inaccurate moisture sources (see p.11). temperature or • Make sure sensor is mounted at least 5 ft off the humidity ground.
  • Page 17: Care & Maintenance

    Care & Maintenance Display Unit Care Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust, dirt and moisture. Clean ventilation ports regularly with a gentle puff of air. 5-in-1 Sensor Care Clean the Sensor Clean with a soft damp cloth.
  • Page 18 3. Press the up or down arrow buttons to calibrate the data value higher or lower from the actual reading. 4. Press the “ ” button to confirm the calibration adjustment. Note: The “CAL” icon remains illuminated next to calibrated values.
  • Page 19: Specifications

    Specifications TEMPERATURE RANGE Outdoor: -40ºF to 158ºF; -40ºC to 70ºC Indoor: 32ºF to 122ºF; 0ºC to 50ºC HUMIDITY RANGE Outdoor: 1% to 99% Indoor: 16% to 98% WIND SPEED 0 to 99 mph; 0 to 159 kph WIND DIRECTION 16 points INDICATORS RAINFALL 0 to 99.99 in;...
  • Page 20: Customer Support

    Customer Support AcuRite customer support is committed to providing you with best-in- class service. For assistance, please have the model number of this product available and contact us in any of the following ways: (877) 221-1252 info@chaney-inst.com AcuRite 24/7 support at www. .com Installation Videos Register your Product...
  • Page 22 ©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copy- rights are the property of their respective owners. AcuRite uses patented technology. Printed in China 00502 INST 070114 Visit www.AcuRite.com/patents for details.

Table of Contents