TECHNICAL
BULLETIN
Subject:
Discontinuation of Mercury Relays
Applies to:
See Below
In order to comply with new Underwriters Laboratories regulations (UL 197), the following
changes have been made to several equipment models:
• Mercury relays have been eliminated and replaced with solid state relays (SSR).
• Temperature limit thermostats have been added to the water tanks as an additional
protection against overheating. The limit thermostat is designed to cut power to the
heaters if the tank temperature reaches 230°F. Once it is tripped, it cannot be reset
and must be replaced.
• Water tanks have been modified to accept the SSRs and limit thermostats.
• CBS-70 Series only: Due to the high amperage of this series, a 100 amp contactor
is being added to the heater protection circuit. If the tank overheats, the limit
thermostat will disable the contactor, which will disable all heaters.
The models that are affected by this change are:
CBS-31Aap
CBS-51H10
CBS-32Aap
CBS-51H15
The following new part numbers have been assigned:*
Part #
Description
108070
relay, solid state, 25 amp, 230 VAC
108071
relay, solid state, 50 amp, 600 VAC
108072
relay, solid state, 125 amp, 600 VAC
53071
thermostat, single shot, 25 amp, 240VAC
53087
thermostat, single shot, 25 amp, 480VAC
53088
thermostat, single shot, 40 amp, 240VAC
52084
contactor, 100amp, 120VAC
* Refer to the wiring diagram on the inside of the machine cover for the specific SSR and thermostat used.
Questions & Answers
Q.) Can equipment manufactured prior to this change be retrofitted with SSRs?
A.) No. The UL listing does not allow field modifications to existing equipment.
Q.) Do the new regulations mean that older machines with mercury relays are no longer
UL listed?
A.) No. This change does not affect the UL listing on equipment manufactured prior to the
new regulations.
Q.) Will FETCO still stock mercury relays for servicing older equipment?
A.) Yes. FETCO will continue to stock mercury relays for the foreseeable future.
Q.) Will the SSRs be located in the same place as the mercury relays?
A.) No. The SSRs will be mounted to the bottom of the water tank in order to use the
tank as a heat sink.
FETCO ♦ 600 Rose Road ♦ Lake Zurich, IL 60047-0429 USA ♦ Tel. (800) 338-2699 or (847) 719-3000 ♦ Fax: (847) 719-3001
NUMBER
22
CBS-52H15
CBS-61H
CBS-52H20
CBS-62H
www.fetco.com
email : techsupport@fetco.com
Date:
June 28, 2006
Rev. January 15, 2007
CBS-71A & AC
CBS-72AT & ATC
CBS-72A & AC
TBS-71AC
(CBS-70 Series only)
(480 VAC only)
(CBS-70 Series only)
(Continued on next page.)

Advertisement

loading

Summary of Contents for Fetco CBS-31Aap

  • Page 1 A.) No. The SSRs will be mounted to the bottom of the water tank in order to use the tank as a heat sink. FETCO ♦ 600 Rose Road ♦ Lake Zurich, IL 60047-0429 USA ♦ Tel. (800) 338-2699 or (847) 719-3000 ♦ Fax: (847) 719-3001 NUMBER...
  • Page 2 Q.) How will this change affect troubleshooting procedures for the brewers? A.) Troubleshooting is similar for both versions. Both relays receive power from the output of the thermostat on the blue wire when the system is calling for heat. When the relay is energized, the circuit closes and current flows from the terminal block to the heaters.