Maintenance

The Imager supplies maintenance-free operation. However, some precautions
should be followed to get the best and longest Imager performance.

Cleaning the Imager

Wipe the case with a damp cloth and a mild detergent. Do not use abrasives,
isopropyl alcohol, or solvents to clean the case or lens/window.

Cleaning the Infrared Lens

If used and stored properly, the infrared lens on your Imager should require
only occasional cleaning. When cleaning is necessary, observe these steps:
1. Using a hand-operated air bulb, gently blow off any dust or debris from
the lens surface.
2. If the surface of the lens still requires additional cleaning after the first
step, use a clean, fine-fiber or micro-fiber cloth, dampened with a mild,
soapy water solution. Gently wipe surface of lens to remove remaining
smudges, debris, or grime.
3. Dry with an absorbent, clean, fine-fiber or micro-fiber cloth.
Minor smudges and grime should not significantly affect the
performance of the Imager. However, large scratches or the removal
of the protective coating on your infrared lens may affect both image
quality and the temperature measurement accuracy.
Use of alcohol, abrasives, solvents, or harsh detergents could damage
not only the protective optical coating on the infrared lens, but also
the sealing materials, rubber components, and adhesives in the lens
assembly. Use of these items to clean the Imager or thermal lens will
void the warranty.