Discharge Temperature Control (Cooling And Heating); Auto. Mode For Automatic Heating/Cooling Switching - Sanyo SPW-D253GH56 Service Manual

Split system
Hide thumbs Also See for SPW-D253GH56:
Table of Contents

Advertisement

2-8 Discharge Temperature Control (Cooling and Heating)

This function prevents the compressor motor from burnout by overheating.
DISCHARGE GAS
TEMP. (°C)
THE TEMPERATURES
IN THE PARENTHESIS
IS FOR 48 TYPE.
OUTDOOR
FAN SPEED
COMPRESSOR
2
ELECTRONIC REF.
CONTROL VALVE
(DISCHARGE TEMP.)
Discharge temperature is sensed by TH8 (discharge gas sensor).
When the temperature rises above 95
steps/30 seconds until the temperature falls below 93
During HEATING operation, when the temperature rises above 105
stops the outdoor fan motor until the temperature falls below 90°C. Please note that this
control does not function during COOLING operation.
For both COOLING and HEATING modes, if the temperature reaches 115
type) the operation shuts down and alarm P3 appears on the remote controller.
The outdoor fan speed is controlled on discharge temp. at heating mode.

2-9 Auto. Mode for Automatic Heating/Cooling Switching

When the AUTO mode is selected, the microprocessor calculates the difference
between the set temperature and the room temperature, and automatically
switches to the COOLING or HEATING mode to maintain the desired
temperature.
This means that if the room temperature is higher or equal to the set
temperature, COOLING operation starts. If the room temperature is lower than
the set temperature, HEATING operation starts.
(135) 115
(125) 105
(115) 95
(113) 93
(110) 90
(105) 85
H OR M
OPEN
Chart Summary and Explanations
Room temp. ] Set temp.
Room temp. < Set temp.
2. Processes and functions
H OR M
M
ON
°
C the electronic refrigerant control valve opens at 50
°
C.
COOLING
HEATING
– 34 –
OPEN
TRIP IS OPERATED.
0439_M_S
Fig. 11
°
C, the control circuit
°
C (135°C for 48
SM830036