Sanyo SAP-CMRV1426EH Technical & Service Manual page 144

Hide thumbs Also See for SAP-CMRV1426EH:
Table of Contents

Advertisement

Table 2
Indoor Unit Combination
Single-room
2.65
Operation
3.5
2.65 + 2.65
2-room
2.65 +
3.5
Operation
3.5 +
3.5
2.65 + 2.65 + 2.65
3-room
2.65 + 2.65 +
3.5
Operation
2.65 +
3.5 +
3.5
3.5 +
3.5 +
3.5
2.65 + 2.65 + 2.65 + 2.65
4-room
2.65 + 2.65 + 2.65 +
Operation
2.65 + 2.65 +
3.5 +
• When one or more SAP-KRVxxEHDS indoor units are operated concurrently with one or more SAP-KMRVxxEH
indoor units, the performance specifications of the SAP-KRVxxEHDS models will decrease by 5% from those listed in
the Table 2.
• The table lists the wall-mounted type of indoor units as representative models.
• For details on the connection of indoor units other than the wall-mounted type, refer to the catalog.
Room Room Room Room
A
B
C
=
2.65
2.65
=
3.5
3.50
=
5.3
2.55
2.55
=
6.15
2.41
3.19
=
7
3.00
3.00
=
7.95
2.08
2.08
2.08
=
8.8
1.88
1.88
2.49
=
9.65
1.72
2.27
2.27
=
10.5
2.08
2.08
2.08
=
10.6
1.56
1.56
1.56
= 11.45
3.5
1.45
1.45
1.45
=
3.5
12.3
1.35
1.35
1.78
Indoor Unit Capacity (kW)
COOLING
Total Performance
Room Room Room Room
D
Capacity
( Min. - Max. )
2.65
(
1.4 - 3.2 )
3.5
(
1.5 - 3.6 )
5.1
(
2.0 - 5.8 )
5.6
(
2.0 - 6.3 )
6.0
(
2.0 - 6.3 )
6.25
(
2.9 - 7.2 )
6.25
(
2.9 - 7.2 )
6.25
(
2.9 - 7.2 )
6.25
(
2.9 - 7.2 )
1.56
6.25
(
2.9 - 7.5 )
1.91
6.25
(
2.9 - 7.5 )
1.78
6.25
(
2.9 - 7.5 )
–3–
NOTE
2.65: SAP-KRV96EHDS
3.5: SAP-KRV126EHDS
HEATING
Total Performance
A
B
C
D
Capacity
3.60
3.6 (
4.20
4.2 (
3.58
3.58
7.15 (
3.42
3.98
7.4 (
3.80
3.80
7.6 (
2.63
2.63
2.63
7.9 (
2.49
2.49
2.91
7.9 (
2.37
2.77
2.77
7.9 (
2.63
2.63
2.63
7.9 (
2.00
2.00
2.00
2.00
8.0 (
1.92
1.92
1.92
2.24
8.0 (
1.85
1.85
2.15
2.15
8.0 (
( Min. - Max. )
1.8 -
4.7 )
1.9 -
5.1 )
2.3 -
8.1 )
2.3 -
8.1 )
2.3 -
8.1 )
3.4 -
8.5 )
3.4 -
8.5 )
3.4 -
8.5 )
3.4 -
8.5 )
3.4 -
8.5 )
3.4 -
8.5 )
3.4 -
8.5 )

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents