2-2. Major Component Specifications

2-2-1. Outdoor Unit
SAP-CMRV1426EH
Outdoor Unit
Control PCB
Part No.
Controls
Control Circuit Fuse
Compressor
Type
Compressor Model / Nominal Output
Compressor Oil ... Amount
Coil Resistance (Ambient Temp. 20 °C)
Safety Device
CT (Peak current cut-off control)
Compressor Discharge Temp. Control
Operation cut-off control in abnormal ambient Temp.
Overload Relay
Run Capacitor
Crankcase Heater
Fan
Type
Q'ty ... Dia.
Fan Motor
Type
Model ... Q'ty
No. of Poles
Rough Measure RPM (Cool:Hi / Heat:Hi)
Nominal Output
Coil Resistance
(Ambient Temp. 20 °C)
Safety Device
Type
Over- Current Protection
Run Capacitor
Heat Exchanger Coil
Coil
Rows
Fin Pitch
Face Area
External Finish
CC
Ohm
Model
Operation Temp.
Micro F
VAC
mm
W
Ohm
Micro F
VAC
mm
m
2
12
CB-CMRV1426EH
Microprocessor
250V 25A
DC Twin Rotary (Hermetic)
C-6RVN93H0M / 1,000W
FV50S ... 350
R - S : 0.482
S - T : 0.482
T - R : 0.482
Yes
Yes
Yes
CS-7L115
Open : 115 °C, Close : 95 °C
-
-
-
Propeller
1 ... D420
DC Motor
DAJ12-55J71-CR ... 1
8
750 / 750
50
RED - WHT :
77.5
WHT - BLU :
77.5
BLU - RED :
77.5
Internal Controller
Yes
-
-
Aluminum Plate Fin / Copper Tube
2
1.3
0.452
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.