Page 2
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price.
Table of Contents Title Page Introduction ................1 How to Contact Fluke ..............2 Safety Information ..............3 Radio Frequency Data ............... 5 Accessories ................7 Before You Start ................. 8 How to Charge the Battery ............. 9 Two-Bay Battery Charger Base........... 9 On-Imager AC Power Socket ..........
Page 4
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Spot Temperatures .............. 31 User-Definable Spot Markers ..........32 Center Box................33 Image Menu ................34 Palette ................. 34 ® IR-Fusion ................36 Color Alarm (Temperature Alarm) ........37 Set High-Temperature Color Alarm .........
Page 5
List of Figures Figure Title Page Lens Cover Laser Warning ............3 IR-OptiFlex Focus ..............13 SD Memory Card Insertion and Removal ........20 Level and Span Settings ............25 MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Introduction The Fluke Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, and TiR125 Thermal Imagers (the Product or Imager) are handheld, infrared imaging cameras for use in many applications. These applications include equipment troubleshooting, preventive and predictive maintenance, and building diagnostics.
To register your Product, visit register.fluke.com. To view, print, or download the latest manual supplement, visit us.fluke.com/usen/support/manuals. To download SmartView software visit www.fluke.com/smartviewdownload. To download the Fluke Connect app, go to iTunes or Google app store and download Fluke Connect. MyFlukeStore 1.877.766.5412 www. .com...
Additional laser warning information is on the inside of the Product lens cover, see Figure 1. US PAT. FCC ID: T68-F125 IC: 6627A-F125 gju05.eps Figure 1. Lens Cover Laser Warning MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Page 10
These objects pose a burn hazard. • Do not disassemble the battery. • Use only Fluke approved power adapters to charge the battery. • Do not disassemble or crush battery cells and battery packs. • Use only specified replacement parts.
Fluke Corporation could void the user's authority to operate the Product. • This section does not apply to the Ti90 and Ti95 models. This Product complies with Part 15 of the FCC Rules. Operation is subject to the two conditions that follow: This Product cannot cause interference.
Page 12
Product Category: With reference to the equipment types in the WEEE Directive Annex I, this product is classed as category 9 “Monitoring and Control Instrumentation” product. Do not dispose of this product as unsorted municipal waste. Go to Fluke's website for recycling information. MyFlukeStore 1.877.766.5412 www.
Warranty Registration Card [1] Fluke Connect is not available in all countries. [2] Fluke recommends the SD memory card that is supplied with the Imager. Fluke does not warrant the use or reliability of aftermarket SD memory cards of different brands or capacities.
When the Imager’s power is off and the ac power adapter is connected, flashes in the center of the display to show that the battery charge is in process. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Keep the Imager attached to the charger until the battery condition icon shows a full charge. If you remove the Imager from the charger before a full charge shows, it may have a reduced run-time.
Performance Series Thermal Imagers Focus Focus Models Ti110, Ti125, TiR110, and TiR125 have IR-OptiFlex focus. The Ti90, Ti95, Ti100, Ti105, and TiR105 use a large depth of field focus-free system. Models with IR-OptiFlex focus can operate in a focus-free mode, but also have the flexibility for close focus situations (<122 cm/48 inches) with a one-touch,...
The secondary trigger operates the laser and LED light. For information about how to enable the laser and torch, see pages 44 and 45. Note The secondary trigger does not apply to the Ti90 and Ti95 models. MyFlukeStore 1.877.766.5412 www.
The option selection menu stays open until you make the selection, go up a menu level, or cancel the action. Table 6 is list of features by model that you access through the menus. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
3. Push to enter the Picture mode. 4. Focus Imager on the object and pull the primary trigger. 5. Push to continue. 6. Push save the picture with the image. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Voice Annotation The maximum recording time is 60 seconds for each image reviewable playback (varies by model). To add a voice (audio) record: 1. With an image in the buffer, push to open the EDIT IMAGE menu.
Pull the trigger to capture the image. The image is now in the buffer and you can save or edit. Push to save the image as a file and go back to the live view. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual SD Memory Card To eject an SD memory card, push in on the exposed edge of the card and then release. The card should pop partially out after you release it. Carefully pull the card out of the slot.
More information is available on emissivity at http://www.fluke.com/emissivity and http://www.fluke.com/emissivityexplanation. We recommend the study of this topic to get the most accurate temperature measurements. MyFlukeStore 1.877.766.5412 www.
Fluke infrared cameras and is supplied with the Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, and TiR125. This software is intended for Fluke Imagers and contains features to analyze images, organize data and information, and make professional ®...
to set the change and go back to the live view. • or to set the change and go back to the previous menu. • to cancel the change and go back to the live view. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Page 30
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Fast Auto/Manual Range Toggle When NOT in a menu mode, push for ½ second to toggle between Auto Range and Manual Range. Fast Auto Rescale When in Manual Range and NOT in a menu mode, push for ½ second to automatically rescale the level and span range for objects in the thermal field of view.
Page 31
Push to decrease or narrow the temperature span. While you adjust the manual span, the scale along the right side of the display shows the thermal span increasing or decreasing in size. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Emissivity Adjustment The correct emissivity values are important for you to make the most accurate temperature measurements. Emissivity of a surface can have a large effect on the apparent temperatures that the Imager observes. Understanding the emissivity of the surface being inspected can, but may not always, allow you to obtain more accurate temperature measurements.
Page 33
to set the change and go back to the live view. • or to set the change and go back to the previous menu. • to cancel the change and go back to the live view. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Reflected Background Temperature Compensation Compensation for reflected background temperature is set in the Background tab. Very hot objects or very cold objects can affect the apparent temperature and measurement accuracy of the target or object of interest, especially when surface emissivity is low.
When you scan with the TiR-Mode on, the Imager displays a slight blurring effect. For best image results, hold the camera steady. Image enhancement cannot be applied to images after they are taken. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Transmission/Transmittance Adjustment When you do infrared inspections through infrared-transparent windows (IR windows), not all of the infrared energy emitted from the objects of interest is transmitted through the optical material in the window. If the transmission percentage of the window is known, you can adjust this percentage in the ...
to cancel the change and go back to the live view. Note If the Display is set to Display All, you see the information about current transmission correction as τ = xxx%. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual User-Definable Spot Markers Up to three adjustable, fixed-temperature spot markers are available on the display. You can use these markers to highlight a region before you save the image. The marker selection is set as All Off, One Marker, Two Markers, or Three Markers.
When satisfied with the size of the Center Box, push: • or to set the change and go back to the previous menu. • to cancel the change and go back to the live view. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Image Menu The Image menu has controls for different features used in the presentation of the infrared image on the Imager's LCD and some saved image and video files.
Page 41
• Amber • • Amber Inverted To set a palette: Push . Push / to highlight Measurement. Push or to view the menu. Push / to highlight Image. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
IR-Fusion has different modes that vary by model, see Table 8. Full Visible mode is also available. (The Fluke Ti100 does not have IR-Fusion and can only display a full infrared image.) Table 8.
The user must manually find and set these parameters. Certain models also display color isotherms, or infrared information, inside or outside of a set of both high and low limits. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Note The Imager does not sense ambient or surface dew point level automatically. To use the low-temperature color alarm function as a dew point color alarm, manual determination and input of surface dew point temperature will yield the best results.
to set the change and go back to the live view. • or to set the change and go back to the previous menu. • to cancel the change and go back to the live view. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Display Graphics Presentation The options for how you view the on-screen graphics are in the Display menu. These options are Display All, Details and Scale, Scale Only, and Image Only.
or to go back to the previous menu. • to cancel the change and go back to the live view. Note shows on the display when the compass cannot make a reading. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Video The Ti110, Ti125, TiR110, TiR125 have .avi (with mpeg encoding) video capture for a maximum of five minutes. The controls include stop, rewind, fast forward, and pause/play functions.
During playback, push or for fast forward and rewind. Push to continue normal playback. Push to exit the playback mode. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Laser Pointer The laser pointer is a sighting aid and is offset from the infrared camera. As a result, it may not always represent the exact center of the infrared or visible image.
to set the change and go back to the live view. • or to set the change and go back to the previous menu. • to cancel the change and go back to the live view. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
The Imager supports the Fluke Connect™ Wireless System (may not be available in all regions). Fluke Connect™ is a system that wirelessly connects your Fluke test tools with an app on your smartphone. It enables you to see images from your infrared camera on your smartphone screen, save images to the asset's EquipmentLog™...
Menus CNX™ Wireless System The Imager supports the Fluke CNX™ Wireless System (may not be available in all regions). It can discover up to 10 3000 Series wireless tools up to 20 meters away. From those 10, you can select 5 tools to view their live measurements on the Imager display.
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual To edit the selection: 14. Push / to highlight the tool name. 15. Push or to view the Edit menu. The Edit menu gives you a choice to display the measurement data and/or save it to the SD memory card.
Push / to highlight Memory. Push . Highlight All Image and push . The Imager prompts you to continue or cancel. 5. Push to delete all files on the SD memory card. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Settings Menu The Settings menu has adjustments for user preferences such as units of temperature measurement, file format of stored data, auto off settings, date, time, and language. This menu also has a section that displays information about the Imager such as model number, serial number, and firmware versions.
Page 57
The .is2 file format can be emailed and then opened with SmartView Software. This format has the maximum versatility. Visit the Fluke website or contact Fluke to find out how to download SmartView analysis and reporting software at no charge.
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Auto Off Auto Off is set as off or on. When set to on, the Imager goes into the Sleep mode after 5 minutes of inactivity. After 20 minutes of inactivity the Imager turns off.
to set the change and go back to the live view. • or to set the change and go back to the previous menu. • to cancel the change and go back to the live view. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Time To set the time: Push . Push / to highlight Settings. Push or to view the menu. Push / to highlight Time. Push or to view the menu.
You can access information about the Imager from the Settings Menu. This includes: • Model • Camera serial number • Refresh rate • Engine serial number • Firmware version • FPGA # • Factory calibration date • Production date MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual To display the Imager Info: Push . Push / to highlight Settings. Push or to view the menu. Push / to highlight Imager Info. Push or to view the menu.
• Always operate in the specified temperature range. Caution Do not incinerate the Product and/or battery. Go to Fluke’s website for recycling information. MyFlukeStore 1.877.766.5412 www.
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual General Specifications Temperature Operating ............-10 °C to +50 °C (14 °F to 122 °F) Storage ..............-20 °C to +50 °C (-4 °F to +122 °F) without batteries Charging ..............
Page 65
Calibration Cycle ..........2 years (assumes normal operation and normal aging) Supported Languages .......... Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
Detailed Specifications Temperature Measurements Temperature Range (not calibrated below -10 °C) Ti90, Ti95, Ti100, Ti105, Ti110 ....... -20 °C to +250 °C Ti125 ............... -20 °C to +350 °C TiR105, TiR110, TiR125 ........-20 °C to +150 °C Accuracy .............. ±2 °C or 2 % (whichever is greater) at 25 °C ambient...