Philips 40PFL9704H/12 Service Manual page 24

Hide thumbs Also See for 40PFL9704H/12:
Table of Contents

Advertisement

EN 24
5.
Q549.3E LA
Important remark:
release reset audio 10 sec after
entering standby to save power
2009-Aug-07
Service Modes, Error Codes, and Fault Finding
Semi Stand by
If ambientlight functionality was used in semi -standby
(lampadaire mode), switch off ambient light
Delay transition until ramping down of ambient light is
finished. *)
transfer Wake up reasons to the Stand by µP.
Switch Memories to self-refresh (this creates a more
stable condition when switching off the power).
Switch AVC system in reset state
Switch reset-PNX5100 LOW
Switch reset-ST7100 LOW
Switch Reset-Ethernet LOW
Wait 10ms
Switch the NVM reset line HIGH
Switch het WP-Nandflash LOW
Disable all supply related protections and switch off
the DC/DC converters (ENABLE-3V3)
Wait 5ms
Switch OFF all supplies by switching HIGH the
Standby I/O line
Stand by
Figure 5-10 "Semi Stand-by" to "Stand-by" flowchart
action holder: MIPS
action holder: St-by
autonomous action
*) If this is not performed and the set is
switched to standby when the switch off of
the ambilights is still ongoing , the lights will
switch off abruptly when the supply is cut.
I_17660_130.eps
140308

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

40pfl9704h/6046pfl9704h/1246pfl9704h/6052pfl9704h/12

Table of Contents