Summary of Contents for IVIEW 3960 Series

  • Page 1 3960 SERIES ENVIRONMENTAL CAMERA INSTALLATION AND OPERATION MANUAL Figure 1. High Performance Environmental Camera Technical Manual 6X-1050a August 11, 2005 Phone: 858-277-6700 info@cohu.com www.cohu-cameras.com Fax: 858-277-0221 Cohu Electronics • 3912 Calle Fortunada • San Diego, CA 92123-1827...
  • Page 2: Table Of Contents

    3960 CAMERA INSTALLATION AND OPERATION LIST OF SECTIONS SECTION TITLE PAGE FCC STATEMENT GENERAL DESCRIPTION Electrical Characteristics This equipment has been tested and Mechanical Characteristics found to comply with the limits for a INSTALLATION Class A Digital Device, pursuant to Part Unpacking and Receiving Inspection 15 of the FCC Rules.
  • Page 3: General Description

    3960 CAMERA INSTALLATION AND OPERATION 1.0 GENERAL DESCRIPTION common third-party software can be used, depend- This introduction briefly describes the overall ing on the requirements of the installation. characteristics of the Model 3960 Camera/ Positioner (figure 1) related to its installation and 1.1.2 Cohu System Control Software operation.
  • Page 4: Mechanical Characteristics

    3960 CAMERA INSTALLATION AND OPERATION Table 1. Specifications SYSTEM RELATED Pan/Tilt Driver Angular Travel 360° continuous pan range; -90 to +90 tilt range P/T Speed (preset) 160° / sec Pan Speed (manual) 0.1° to 80° sec Tilt Speed (manual) 0.1° to 40° sec Preset Accuracy >0.1°...
  • Page 5 3960 CAMERA INSTALLATION AND OPERATION Table 1. Specifications (continued) CAMERA RELATED Imager 1/4-inch interline transfer color CCD Resolution NTSC or PAL: 470 horizontal tv lines S/N Ratio >50 dB Sensitivity Color, day, 1/60 sec 3.0 lux Color, day, 1/4 sec 0.2 lux Mono, night, 1/60 sec 0.3 lux...
  • Page 6 3960 CAMERA INSTALLATION AND OPERATION 396 x — x x x x xxxx ACCESSORIES SERIES VIDEO DSP Color Camera 0 None FORMAT Pressurized Housing 3 NTSC Assigned Sunshield 7 PAL MOUNT PROTOCOL PEDD Pedestal - Small Base POWER OPTIONS LPED Pedestal, Large Base WALL Wall Mount...
  • Page 7: Installation

    3960 CAMERA INSTALLATION AND OPERATION Figure 3. Optional LPEDD Adapter Plate Figure 7. Parapet Mount The pressure relief valve should be lifted off its seat during purging of the camera. This aids in the flow of gas through the housing while purging moisture laden air from inside.
  • Page 8: Unpacking And Receiving Inspection

    3960 CAMERA INSTALLATION AND OPERATION Components used in modern electronic equip- general installation requirements of bolting the 3960 ment, especially solid state devices, are susceptible in place. . A prime consideration will be routing of to damage from static discharge. The relative sus- the system cable to a 3960.
  • Page 9: Equipment Required But Not Supplied

    3960 CAMERA INSTALLATION AND OPERATION Figure 8. Dimensions, Model 3960 If the optional large mounting base is ordered 422/232 converter will be required. Most PC’s have (LPEDD option) it will be supplied with four 1/4-20 x only a serial RS-232 communications port. 3/4 mounting screws.
  • Page 10 3960 CAMERA INSTALLATION AND OPERATION Table 3. Items Supplied Table 4. Item Typically Required But Not Supplied IT E M S S U P P L IE D IT E M S T YP ICAL LY RE QUIRE D BUT NOT S UP P L IE D IT E M DE S CRIP T ION Co h u P a r t Nu m b e r...
  • Page 11: Power Requirements

    3960 CAMERA INSTALLATION AND OPERATION Table 5. 3960 Connector & Mating Cable Plug CAME RA P IGTAIL MAT ING S YS TE M DE S CRIP T ION CONNECTOR CABLE P LUG C onnector Housing 1310306-010 C ohu 1310307-009 9 10 Backshell 1310307-103 Cohu 1310307-103...
  • Page 12: Installation Procedure

    3960 CAMERA INSTALLATION AND OPERATION Connect 115 V ac Either 115 V ac 24 V ac 24 V ac 3960 (Depends on Camera Model) Picture Monitor 75 Ohm Coax Terminated 75 Ohms Use Test Cable CTC-30 for 115 V ac use Use Test Cable CTC-35 for 24 V ac use Converter Twisted...
  • Page 13 3960 CAMERA INSTALLATION AND OPERATION FUNCTION video, 75 ohm ground, video ground, data Table 6. Pin Functions, 115 V ac Camera Connector 115 V ac line (high/hot) 115 V ac neutral (low) shield, overall cable ground, ac nc designates not connected (not used) Figure 12.
  • Page 14 3960 CAMERA INSTALLATION AND OPERATION FUNCTION video, 75 ohm ground, video Table 7. Pin Functions, ground, data 24 V ac Camera Connector 24 V ac low shield, overall cable ground, ac 24 V ac high nc designates not connected (not used) Figure 13.
  • Page 15: Preparation For Shipment And Storage

    3960 CAMERA INSTALLATION AND OPERATION camera housing. If the camera module should loose some dry nitrogen during high altitude transporta- tion (as indicated by a pressure reading below about 5 psig) then some additional dry nitrogen may be added to replenish the lost nitrogen. This valve should be manually lifted off its seat or pushed slightly to the side when it is desired to flow dry nitrogen through the camera to purge...
  • Page 16 3960 CAMERA INSTALLATION AND OPERATION Figure 16. Cable Schematics, Type CA-297 (A and B Versions) (C and D versions and Notes on next page) 6X-1050a...
  • Page 17 3960 CAMERA INSTALLATION AND OPERATION CONNECTOR RS-232 TO RS-422 CA-295 ACCESSORY ACCESSORY CONNECTOR ACCESSORY (MAIN) CONVERTER 1310308-002 (6-contact) 1310307-103 1310307-009 — — — (clamp) 1310308-008 (5-contact) 1310308-002 (6-contact) 1310307-103 1310212-004 1310307-009 — — (clamp) (BNC) 1310308-008 (5-contact) 1310308-002 (6-contact) 1310307-103 1310212-004 1310307-009 —...
  • Page 18: Local Panel Control

    3960 CAMERA INSTALLATION AND OPERATION central control facility, it is possible to connect a tv For shipment, package with enough foam monitor to the Panel and control basic functions of padding or other packing material to prevent dam- the 3960. A laptop PC running Windows would age that can occur during shipping.
  • Page 19 3960 CAMERA INSTALLATION AND OPERATION Figure 17. Dimensions, 3960 Standard Base (Permanent Part of 3960) Fastens to Standard Base Above Four 1/4-20 x 3/4 Flathead Screws Included Cohu P.N. 0310010-093 Figure 18. Dimensions, Optional Large Base (attaches to base above) 6X-1050a...
  • Page 20 Click on the FIND button at the upper left of the window. A pop-up window will appear while Win selections to (this Receiver iDome/iView/IView2 MPC searches for all allowable 3960 addresses (1 is the series to which the 3960 belongs) to 223). b. At the...
  • Page 21 3960 CAMERA INSTALLATION AND OPERATION Figure 20. Cohu WinMPC Home Screen to perform tests and setups. If this is not the required address for this 3960, Check all the Momentary functions: zoom, then change the address to the required number focus, iris, color, and integration.
  • Page 22: Mounting Methods

    3960 CAMERA INSTALLATION AND OPERATION Figure 21. WinMPC Setup Screen MOUNTING METHODS tight places. It is also necessary to plan for weather- Since installation of a 3960 may require that it proofing any through-wall holes be mounted to any of a variety of structures, differ- ent types of mounting assemblies are required.
  • Page 23: Large Base Plate Installation

    3960 CAMERA INSTALLATION AND OPERATION The 1/4-20 fasteners threaded into these pattern. If site-supplied flathead screws are used holes must not protrude through the base more they must not protrude through the standard base than 0.1 inch. plate by more than 0.1 inch. More than this would The 3960 can be directly mounted to the wall jam into the 3960 housing.
  • Page 24: Pole Mount Installation

    3960 CAMERA INSTALLATION AND OPERATION Figure 22. Dimensions, Wall Mount Arm 4. Install a weather tight gasket between the arm and 4.4 POLE MOUNT INSTALLATION the surface of the wall (if this is required). Figure 5 shows the pole mount bracket. 5.
  • Page 25: Corner Mount Installation

    3960 CAMERA INSTALLATION AND OPERATION Figure 23. Dimensions, Pole Mount 8. Pull the system cable back so the arm can be slid 1. Verify that the system cable has been properly over the pole mount threaded studs.. routed to a location where the pole-mount bracket will be attached.
  • Page 26: Parapet Mount Installation

    3960 CAMERA INSTALLATION AND OPERATION 1. Verify that the system cable has been properly routed to a location where the corner-mount bracket will be attached. Plan the routing before doing any installation. 2. Attach the connector to the system cable (if not already installed).
  • Page 27 3960 CAMERA INSTALLATION AND OPERATION Figure 25. Dimensions, Parapet Mount 8. Pull the system cable back so the arm can be slid over the parapet mount threaded studs.. 9. Install lock washers and nuts to secure the arm to the bracket.. 10.
  • Page 28 3960 CAMERA INSTALLATION AND OPERATION COHU ELECTRONICS WARRANTY Cohu, Inc., Electronics Division warrants equipment manufactured to be free from defects of material and workmanship. Any part or parts will be repaired or replaced when proven by Cohu examination to have been defective within two years from date of shipment to the original purchaser for standard CCD cameras and one year from date of shipment to the original purchaser for intensified CCD cameras and all other Cohu manufactured products.