Connectors; Power Connector (X7); Mcu Pin Header Connectors (X1 And X2); Lin-Uart Connectors (X5, X9) - Fujitsu SK-96380-120PMC User Manual

Mb96300 series
Table of Contents

Advertisement

4 Connectors

4.1 Power connector (X7)

The following figure shows the power connection jack X7. This connector is used to connect
an external unregulated DC power supply voltage (9V-15V DC) to the evaluation board.
Connector X7:

4.2 MCU pin header connectors (X1 and X2)

All pins (except oscillator and supply pins) of the microcontroller are directly connected to pin
headers. Pin 1 of the MCU corresponds to Pin 1 of the connector. Pin 2 of the MCU
corresponds to Pin 2 of the connector, and so on.

4.3 LIN-UART connectors (X5, X9)

Two 9-pin D-Sub female connectors are used for the serial interfaces. Note that X5 and X9
are shared between the RS232- and LIN transceivers and must be configured to the desired
functionality (refer to chapter 3.9 for details).
Pin Number
Pin Signal
1
+VBat
2
3
4
5
6
7
8
9
LGND
Shield
UG-960019-11
SK-96380-120PMC User Guide
Chapter 4 Connectors
Shield is connected to GND (-)
+
Center is connected to positive voltage supply (+)
Figure 4-1: Power Connector
Figure 4-2: UART Connector
Description
Power from / to LIN bus
TXD
RS-232 transmit output
LIN
Bi-directional LIN-interface bus
RXD
RS-232 receive input
DTR
Connected to DSR (pin 6)
GND
Ground normally used for RS232 connection
DSR
Connected to DTR (pin 4)
RTS
Can be connected with CTS by jumper
CTS
Can be connected with RTS by jumper
Ground normally used for LIN connection
GND
Ground
Table 4-1: UART Connector Signals