3.9 LIN / UART

There are two identical circuit blocks for LIN or RS232 connections. Each of the two D-Sub
connectors can be configured as LIN or RS232 interface. DTS or RTS can be selected as
reset source, and RTS and CTS can be connected by a jumper, since some terminals and
Flash programming tools need this connection. Pin 1 (Vs) of X5 and X9 can be connected to
the voltage input of the board by jumpers in order to supply the LIN bus.
3.9.1 LIN-UART 0 (JP: 19, 21, 23, 25, 27, 28, 29, 31)
Jumper
JP21
(RXD)
JP25
(TXD)
JP27
(RS232/LIN)
JP19
(RTS-CTS)
JP23
(DTR/RTS)
JP29
(LIN enable)
JP31
(LIN master)
JP28
(LIN Vbat)
UG-960019-11
SK-96380-120PMC User Guide
Chapter 3 Jumpers and Switches
Setting
Description
1-2
SIN0 is connected to RS232 transceiver
2-3
SIN0 is connected to LIN transceiver
1-2
SOT0 is connected to RS232 transceiver
2-3
SOT0 is connected to LIN transceiver
1-2
X5 pin 2 is connected to RS232 transceiver
2-3
X5 pin 2 is connected to LIN transceiver
Closed
RTS and CTS of X5 are connected
Open
RTS and CTS of X5 are not connected
1-2
DTR signal (pin 6 of X5) is used as reset source
2-3
RTS signal (pin 7 of X5) is used as reset source
Closed
LIN transceiver is enabled
Open
LIN transceiver is disabled
Closed
LIN-UART0 is LIN Master
Open
LIN-UART0 is LIN Slave
Closed
LIN bus (X5 pin 1) is powered by the board
Open
LIN bus (X5 pin 1) is not powered by the board
Table 3-7: UART0 Settings