Metrologic Eclipse MS5100 Series Installation And User Manual page 31

Hide thumbs Also See for Eclipse MS5100 Series:
Table of Contents

Advertisement

D
S
ESIGN
PECIFICATIONS
E
LECTRICAL
Input Voltage
Power - Operating
Current - Operating
DC Transformers
UL
Laser Class
EMC
E
NVIRONMENTAL
Operating
Temperature
Storage Temperature
Humidity
Light Levels
Shock
Contaminants
Ventilation
5 VDC ± 0.25 V
675 mW
125 mA peak @ 5 VDC
Class 2; 5.2 V @ 650 mA
UL listed for US and Canada;
UL 60950, C22.2 No. 60950
CDRH and IEC Laser Class 1
with IEC 60825-1:1993 + A1:1997 + A2:2001 Class 1
Class B: FCC Part 15, ICES-003, European Union
Directive 89/336/EEC
0°C to 40°C (32°F to 104°F)
-40°C to 60°C (-40°F to 140°F)
5% to 95% relative humidity, non-condensing
Up to 4842 Lux (450 footcandles)
Designed to withstand 1.5 m (5') drops
Sealed to resist airborne particulate contaminants
None required
-
In accordance
27