    CONTENT Warning....................1 Ⅰ. Brief Introduction ................3 III.Series Model .................. 4 IV.Technical Specification ..............5 V. Structure ................... 7 VI.LCD Display ................... 8 VII.Operation ..................10 A. Tester Operation ................10 1. Power On/Off ................10 2. General Test ................11 3.
  • Page 5: Warning

    Warning Thanks for your purchase of ETCR9200 H/L Voltage Clamp Current Meter of our company. In order to make better use of this product, please make sure to: ——Read this manual in detail and the operator must totally understand this manual and be in proficient in operation of this meter before making test on spot.
  • Page 6 u To avoid the impact of transducer clamp, it needs to maintain this meter regularly. Do not use corrosive or coarse materials to clean, but use soft cloth (such as glasses cloth), dipping clean anti-rust desiccant lubricant (such as WD-40), and making a gentle wiping.
  • Page 7: Ⅰ. Brief Introduction

    Ⅰ. Brief Introduction ETCR9200 Series H/L Voltage Clamp Current Meter has broken through the traditional structure, which is specially well-designed for measuring high voltage current, adopt latest CT technology and integrated mask digital technology, composed of special clamp current meter and high voltage insulation rods. Without insulation rods, it can used as high-precision low-voltage clamp meter and leakage current meter, can accurately measure the current or leakage current of 0.01mA.
  • Page 8: Series Model

    Warning! It must strictly abide by the safety rules. Otherwise, it may cause personal damage or casualty accident. Alternating Current (AC) Direct Current (DC) III.Series Model Range of Model Accuracy Description measurement Specification ETCR 9200 Base 0.00mA-1000 Φ68mm 0.01mA ETCR 9200B Wireless...
  • Page 9: Technical Specification

    IV.Technical Specification High voltage AC current measurement, low Function voltage AC current, leakage current measurement, on-line AC current supervision. Power Supply DC6V Alkaline Dry Battery (1.5V AAA X 4) Test Method Clamp CT, Integral Method *Transmission ETCR9200B 433MHz Wireless Transmission Method *transmission distance...
  • Page 10 Automatically maintain the height of the tes t value,usually in the test mode press PE Peak “PE” , AK key, LCD top right corner will display Maintenance that is, to keep open the PEAK function, th en press PEAK key to cancel this function Test insulating sheath wires (...
  • Page 11: Structure

    Storage -10℃~ 60℃; ≤70%Rh Temperature and Humidity Avoid same frequency interfere(315MHz & Interference 433MHz) Insulated Rod φ32mm, 1m/ Section(5 Sections) Dimension Tester/receiver:AC 2kV/rms(Between core and shell) Insulation Insulating rod: AC 100kV/rms (5 sections Intension insulating rod all connections, between both ends) Structure Anti-Dripping Type II...
  • Page 12: Lcd Display

    test test(wireless) receiver VI.LCD Display 1.Explanation for Special Symbols ⑴. Low battery symbol, when the voltage of battery is lower than 4.8V, this symbol display, please replace battery in time. ⑵.“OL A” This symbol indicates that the current on test has exceeded the maximum measurement limit of the meter.
  • Page 13 ⑸.“MR” data access symbol, which is displayed during looking up data, meanwhile, it will display the serial number of data in storage. ⑹.“End” exit symbol, it will display during the exit. ⑺.“dEL” data delete symbol, it will display when deleting data. *⑻.“no- -”...
  • Page 14: Operation

    ——It can’t store more unless delete storage ⑹.——“dEL” Indication of data delete ⑺.—— “End” Indication of exit *⑻.——“no- -”Dynamic display: none received signal VII.Operation Please check all parts of the meter carefully before usage, to see whether there is any damage. And make sure no damage before usage.
  • Page 15: General Test

    Under PEAK testing mode,press POWE button to power off. Under data reference mode, firstly press POWER button for more than 3 seconds to exit from data reference mode, returning to normal test mode, then press POWER button to power off. During the exit from data access, it will display “End”...
  • Page 16 Before test, firstly to connect insulation rod, which must be connected in right position, and then to connect tester, avoiding the impact of meter to ground surface. Make sure to use specially equipped insulation rod to connect with the meter. After test, it should incline the insulation rod accordingly on drawing in.
  • Page 17: Peak Test

    Under HOLD mode, press HOLD button to cancel HOLD function, and return to normal testing mode. Under data reference mode, press POWER button for more than 3 seconds to exit from data reference mode, returning to normal testing mode. Under PEAK testing mode, press POWER button to exit from PEAK testing mode, returning to normal testing mode.
  • Page 18: Data Reference

    groups of data, in case of full storage, “FULL” symbol will display by flash continuously, and it cannot continue to memory until cleaning out the previous memory. 6. Data Reference Under normal testing mode, press PEAK + POWER button to enter data reference mode, meanwhile, it will automatically display data saved in the group 01.
  • Page 19: Data Reception

    bit lower. Please replace battery. 15 minutes after powering on the meter, if it remains idle, an auto-power off procedure starts to preserve the battery life and LCD will continue flash until the complete switch off takes place after 30 seconds. In case of LCD continuous flash, press POWER button, then the meter will continue to work.
  • Page 20: Data Deletion

    HOLD button or POWER button to read the stored data by turning upwards or downwards in cycle. It will return to the group 1’s data automatically after reaching the last group’s data in storage. Press POWER button for more than 3 seconds to exit from data reference mode, returning to receiving data mode.
  • Page 21: Accessories

    IX. Accessories Tester 1PCS *Receiver (ETCR 9200B special ) 1PCS Insulation Rod (1M/Section) 5 Sections Meter Box 1PCS 4 PCS(* or 8 PCS) Battery (Alkaline Dry Battery AAA) User’s Manual/ Maintenance Card/ 1SET Conformity Certificate...
  • Page 22 Manufactured by ETCR Electronic Technology Company Address: F-3F, No.4 Pengshang Zhifu Road, Jiahe, Baiyun District, Guangzhou, Guangdong, China Post Code: 510440 Tel: (86-20)62199556 62199554 Fax: (86-20)62199550 E-mail: info@etcr.cc Website: www.etcr.cc...