Daikin FTXS-A Series Technical Manual page 19

Inverter single split air conditioner wall mounted. heatpump 50hz
Table of Contents

Advertisement

(b) Indoor Condition: 25°C DB, 19°C WB
Outdoor Condition: 35°C DB
EWB
EDB
24
19
25
27
Repeat the same process for (c) & (d) in 1
(c) x
= 2.17 kW; y
= 2.17 kW; z
3
3
2
Step:
nd
To obtain the TC, SC & PI for
(a) Indoor Condition: 25°C DB, 17°C WB
Outdoor Condition: 35°C DB
EWB
EDB
16
17
25
19
Repeat the same process for (b) in 2
(c) x
= 2.22 kW; y
= 2.05 kW; z
6
6
3
Step:
rd
To obtain the TC, SC & PI for
(a) Indoor Condition: 25°C DB, 17°C WB
Outdoor Condition: 37°C DB
EWB
EDB
25
17
By Interpolation Method
37°C – 35°C
=
40°C – 35°C
⇒ x = 2.34 kW
Outdoor temperature
35°C
TC
SC
PI
2.55
1.82
0.69
x
y
z
2
2
2
2.56
2.12
0.69
Step
st
= 0.69 kW
3
Outdoor temperature
35°C
TC
SC
PI
2.35
2.35
0.68
x
y
z
5
5
5
2.55
1.92
0.69
Step
nd
= 0.71 kW
6
Outdoor temperature
35°C
TC
SC
PI
2.42
2.21
0.68
x – 2.42 kW
2.22 kW – 2.42 kW
By Interpolation Method
25°C – 24°C
27°C – 24°C
⇒ y
= 1.92 kW
2
Similarly,
x
= 2.55 kW
2
z
= 0.69 kW
2
(d) x
= 2.34 W; y
4
By Interpolation Method
17°C – 16°C
19°C – 16°C
⇒ x
= 2.42 kW
5
Similarly,
y
= 2.21 kW
5
z
= 0.68 kW
5
37°C
TC
SC
PI
x
y
z
Similarly,
y = 2.15 kW
z = 0.69 kW
Performance Data
y
– 1.82 kW
2
=
2.12 kW – 1.82 kW
= 1.80 kW; z
4
4
x
– 2.35 kW
5
=
2.55 kW – 2.35 kW
40°C
TC
SC
PI
2.22
2.05
0.71
= 0.75 kW
15

Hide quick links: