How to Wire Your Ceiling Fan - C28 Remote Control

If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a
licensed electrician.
▲WARNING
To avoid possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
1. Setting the Code: The remote unit has 16 different
code combinations. It may be necessary to test a couple
frequency code settings to improve signal reception
and/or eliminate interference from other remote control
household items. Multiple fans should have different code
settings to allow independent fan control. To set the code,
perform these steps.
• Transmitter: remove battery cover. Press fi rmly below
arrow and slide battery cover off. Slide code switches to
your choice of up or down position. Factory setting is all
up. Do not use this position. With a small screwdriver or
ball point pen slide fi rmly up or down (Figure 1a). Replace
battery cover on the transmitter.
• Receiver: Slide code switches to the same positions
as set on your transmitter (Figure 1b).
2. Installing Receiver in Hanger Bracket:
• Slide remote Receiver into the Hanger Bracket
(Figure 2).
• Connect wires as indicated: (Figure 3)
• Green Hanger Bracket & Hanger Ball wires to BARE
(ground) wire.
• BLACK Receiver Unit wire (AC IN L) to BLACK supply
wire.
• WHITE Receiver Unit wire (AC IN N). to WHITE supply
wire.
• WHITE Receiver Unit wire (TO MOTOR N) to WHITE
fan wire.
• BLACK Receiver Unit wire (TO MOTOR L) to BLACK
fan wire.
• BLUE Receiver Unit wire (FOR LIGHT DOWN) to BLUE
light wire.
• GRAY Receiver Unit wire (REVERSE MODULE) to
GRAY wire.
• Position all connected wires and receiver antenna to
allow installation of ceiling canopy.
• Using canopy screws threaded into the hanger bracket
install ceiling canopy. (see page 8)
3. After making the wire connections, the wires should
be spread apart, turned upward and pushed carefully up
into the outlet box, with the grounded conductor and the
equipment-grounding conductor on one side of the outlet
box and the ungrounded conductor on the other side of the
outlet box.
Remote Transmitter
Unit Detail
Battery
Figure 1a
NOTE:
If fan or supply wires are different colors
than indicated, have this unit installed by a qualifi ed
electrician.
GRN or BARE GROUND
WH-TO MOTOR N
BLK-TO MOTOR L
GRAY-REVERSE MODULE
BLUE-FOR LIGHT DOWN
▲WARNING
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not operate
fan until the blades is in place. Noise and fan damage
could result.
7
Reciever Unit Detail
9V
Figure 1b
Ceiling
Bracket
(Open End)
Receiver Unit
NOTE: Receiver wires omitted for clarity.
Figure 2
WH-AC IN N
BL-AC IN L
120 VAC SUPPLY
BLK-ANT
Figure 3
(User Supplied)