Battery Replacement; Connections; Nvh Magnet Mounting Instructions - pico Technology PicoDiagnostics NVH Quick Start Manual

Table of Contents

Advertisement

Pico Technology
Pico Technology
3.
3.

Battery replacement

Battery replacement
1.
1.
Place the NVH Interface face down and remove the four securing screws.
Place the NVH Interface face down and remove the four securing screws.
2.
2.
Remove the base cover from the NVH Interface.
Remove the base cover from the NVH Interface.
3.
3.
Lift the old battery away from the connections.
Lift the old battery away from the connections.
4.
4.
Place the new battery in position. Make sure it has
Place the new battery in position. Make sure it has
the correct orientation.
the correct orientation.
5.
5.
Replace the base cover and secure it.
Replace the base cover and secure it.
4.
4.

Connections

Connections
1.
1.
Connect the oscilloscope to your computer with the blue
Connect the oscilloscope to your computer with the blue
USB cable supplied with the oscilloscope.
USB cable supplied with the oscilloscope.
2.
2.
Connect the NVH Interface box to the PicoScope with the supplied BNC cables.
Connect the NVH Interface box to the PicoScope with the supplied BNC cables.
You will require one BNC cable when you use a microphone and up to three when
You will require one BNC cable when you use a microphone and up to three when
you use an accelerometer.
you use an accelerometer.
3.
3.
Connect either the microphone (a) or the accelerometer (b) to the NVH Interface.
Connect either the microphone (a) or the accelerometer (b) to the NVH Interface.
Note: The extension cable provided may be used to extend the reach of either the
Note: The extension cable provided may be used to extend the reach of either the
microphone or the accelerometer.
microphone or the accelerometer.
4.
4.
Run the PicoDiagnostics software.
Run the PicoDiagnostics software.
(a)
(a)
5.
5.

NVH Magnet mounting instructions

NVH Magnet mounting instructions
1.
1.
contamination.
contamination.
2.
2.
Slide the keeper off the mounting magnet(s).
Slide the keeper off the mounting magnet(s).
3.
3.
Mount the magnet/sensor assembly to the prepared test surface by gently rolling
Mount the magnet/sensor assembly to the prepared test surface by gently rolling
it into place. This will avoid damaging the surface.
it into place. This will avoid damaging the surface.
Note:
Note:
small steel disk to the chassis with cyanoacrelate glue that you can use as a mounting
small steel disk to the chassis with cyanoacrelate glue that you can use as a mounting
location.
location.
DO347
DO210-9
DO210-9
Quick Start Guide
Quick Start Guide
(b)
(b)
3
3