The thermostatic control used on this model
differs from standard thermostats. Standard
thermostats simply turn the burner on and off.
The thermostat used on this heater senses the
room temperature. At times the room may ex-
ceed the set temperature. If so, the burner will
shut off. The burner will cycle back on when
Shutting Off Heater
Turn control knob clockwise
OFF position.
1. Remove screen by lifting and pulling
forward.
2. Follow steps 1 through 5 under Lighting
Instructions, page 19.
3. With control knob in PILOT position, strike
match, and hold near pilot. Press in control
knob; pilot should light.
20
OPERATION
THERMOSTAT CONTROL OPERATION
TO TURN OFF GAS TO APPLIANCE
to the
MANUAL LIGHTING PROCEDURE
www.factorybuysdirect.com
room temperature drops below the set tem-
perature. The control knob can be set to any
comfort level between HIGH (5) and LOW (1).
Note: The thermostat sensing bulb measures
the temperature depending on housing con-
struction.
Shutting Off Burner Only
(pilot stays lit)
Turn control knob clockwise
PILOT position.
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.