Factory Buys Direct PFS FDF150T Owner's Operation And Installation Manual page 12

Vent-free gas fireplace insert
Table of Contents

Advertisement

WARNING: Do not allow any
combustible materials to overlap
the firebox front.
WARNING: Do not allow
combustible or noncombustible
materials to cover any necessary
openings like louvered slots.
WARNING: Never modify or
cover the louvered slots on the
front of the firebox.
Built-in installation of this fireplace involves
installing fireplace into a framed-in enclosure.
This makes the front of the fireplace flush
with wall. If installing a built-in mantel above
the fireplace, you must follow the clearances
shown in Figure 6.
NOTICE: Surface temperatures
of adjacent walls and mantels be-
come hot during operation. Walls
and mantels above the fireplace
may become hot to the touch.
If installed properly, these tem-
peratures meet the requirement
of the national product standard.
Follow all minimum clearances
shown in this manual (see Figure
4, page 9 and Figure 7).
1. Frame in rough opening. Use dimensions
shown in Figure 8 for the rough opening.
If installing in a corner, use dimensions
shown in Figure 9 (page 13) for the rough
opening. The height is 19", which is the
same as the wall opening above.
2. Carefully set fireplace in front of rough
opening with back of fireplace inside wall
opening.
12
INSTALLATION
BUILT-IN FIREPLACE INSTALLATION
www.factorybuysdirect.com
1/4" Clearance to Facia
3/8" Clearance to Sides, Back and Top
15
16"
Figure 6 - Clearance to Combustibles
Safe Zone
12"
9"
To
6"
Ceiling
3"
1
/
"
1
2
Hood Top
Fireplace
Figure 7 - Fireplace Clearances
9
/
"
1
4
1 1 "
15
/
"
5
8
Figure 8 - Rough Opening for Wall
Installation
/
"
5
8
1
/
3
4
Slope
Factor
200200-01C
"