7-2 Outdoor Unit

AR09RXFPEWQXEU
AR12RXFPEWQXEU
AR18RXFPEWQXEU
INVERTER PCB
CNP051
CNP052
INVERTER
CNP401
(WHT)
CNP230
(BLK) INV
DOWNLOAD
CNP901
(WHT)
CNP552
CNP361
CNP351
(WHT) ECO
(WHT)
(WHT)
DOWNLOAD
ECO-COMM
MAIN-COMM
4
8
(OPTION)
8
CN261
CN302
COMM-INV
(WHT)
MAIN PCB
CN230
(BLK) MAIN
DOWLOAD
CN281
CN701
CN291
CN301
(WHT)
(RED)
(WHT)
(RED)
4
4
4
4
4
CN001(N)
SKY-BLU
CN003
CN004
(BLU)
(WHT)
HEATER PCB
CN001(L)
EEV-A
BRN
(OPTION)
DESCRIPTION
LED PATTERN
7SEG
DISPLAY
YEL GRN RED
POWER OFF / VDD NG
Power ON reset (1sec)
NORMAL OPERATION
Abnormal Communication
(Indoor <-> Outdoor
E464
IPM Over Current (O.C) Error
E461
Comp Starting Error
E470
EEPROM Data Error (no data)
E466
DC-Link Voltage Under/Over Error
E484
PFC Over Load Error
E483
Over Voltage Protection Error
E221
OUT-TH (Outdoor Temperature) Sensor Error
E416
DIS-TH (Discharge Temperature) Over Error
E251
DIS-TH (Discharge Temperature) Sensor Error
E468
Current Sensor Error
E474
Heatsink Sensor Error
E485
Input Current Sensor Error
E465
Comp V_limit t/l_limit Error
E500
Heatsink Over Temperature Error
E231
CON-TH (Cond Temperature) Sensor Error
E203
Time out Comm. (Inv Micom<->Main Micom)
E458
Fan Error
E471
EEPROM Data Error (Main Micom<->Inv Micom)
E467
Comp Wire Missing Error
E440
Prohibit Operation Condition Error (Heating)
E441
Prohibit Operation Condition Error (Cooling)
E469
DC-Link Voltage Sensor Error
E488
AC Input Voltage Sensor Error
E462
AC Input I_Limit Trip Error
E554
Gas Leak Error
E422
EEV or Valve Close error-Self diagnosis
Test Operation at Cooling Mode
Test Operation at Heating Mode
DB68-07643A
68
CNP031
(WHT)
(OPTION)
CNP001
(WHT)
(OPTION)
(OPTION)
DB68-07643A-00