Page 2
IN NO CASE, WHETHER AS A RESULT OF A BREACH OF CONTRACT, BREACH OF WAR- RANTY OR TORT (INCLUDING STERIS'S OR CUSTOMER'S WILLFUL ACTS OR NEGLIGENCE OR STRICT LIABILITY) SHALL STERIS OR CUSTOMER BE LIABLE TO THE OTHER FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES INCURRED BY THE OTHER, INCLUDING, BUT NOT LIMITED TO, LOSS OF REVENUE, PROFITS OR GOODWILL.
Page 3
Once installed, equipment operation should be tested by a qualified service technician prior to your usage of the equipment. If STERIS supervision is desired for installing and starting up this equipment, contact your local STERIS representative. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 ®...
Page 4
Direct Technical Assistance Direct Technical Assistance Sales Sales Direct Technical Assistance Direct Technical Assistance STERIS Corporation STERIS Field Engineering 5960, Heisley Road 2424, West 23rd Street, Mentor, Ohio 44060-1834 Erie, PA 16506 Tel.: 440 354 2600 Tel.: 814 452 3100...
TABLE OF CONTENTS SECTION SECTION TITLE TITLE PAGE PAGE SECTION SECTION SECTION TITLE TITLE TITLE PAGE PAGE PAGE LISTING OF WARNINGS, CAUTIONS AND SYMBOLS ............1-1 UNCRATING INSTRUCTIONS ......2-1 Open the Crate ............2-1 Remove Crate and Packing ........2-1 Remove Base and Move Washer/Disinfector ...
LISTING OF WARNINGS, CAUTIONS AND SYMBOLS The following is a listing of safety precautions which must be observed when uncrating, installing, and checking this equipment. WARNINGS indicate the potential for danger to personnel and CAUTIONS indicate the potential for damage to equipment. These precautions are repeated (in whole or in part), where applicable, throughout the instructions.
Page 7
CAUTION (Cont'd) Once three-phase power is connected, check pump for correct rotation, indicated by arrow on pump motor. Incorrect pump rotation may result in pump damage and improper washing action. If unit must be tilted, tilt onto left or right side. Handles and control panels could be damaged if unit is tilted onto front (soiled) or back (clean) side.
3. Pull out and discard the wooden base under the washer. WARNING - PERSONAL INJURY AND/OR EQUIPMENT DAMAGE 4. Move washer to installation site. HAZARD: To tilt the washer/ 5. Lower the washer. disinfector, more than one per- required. Washer/ 6.
Page 10
f. Check that cables are seated in the pulley grooves (see Figure 2-5). g. Replace left side panel. Pulley h. Repeat steps a. through g. for back (clean) side door. 3. Open chamber door. Remove nylon straps holding spray Cable headers to frame.
Utility service lines: • Shutoff valves (not by STERIS) should be installed on steam and water lines to washer/disinfector (see Figure 3-1). Shutoff valves allow washer/disinfector to be ser- viced without shutting off building supply.
Page 12
5. WASTE - Connect washer/disinfector drain line to building waste line. 6. VENTILATION - Connect washer/disinfector ventilation to build- ing ventilation, as required. 7. Open building supply valves and check for leaks: correct if necessary. 8. ELECTRIC - Connect building electrical supply to washer/ disinfector.
9. When cycle is over, the CYCLE COMPLETE light comes on. Open door and remove the accessory. 10. Clean chamber filters. Replace filters in chamber and close chamber doors. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 NOTE: Always use a non-foaming detergent for effective cleaning Second Operational Test...
Page 17
This unit is now ready for a thorough System Field Test, Calibration and a first time Preventive Maintenance Checklist Inspection by a qualified STERIS service representative. Con- tact your Steris Sales Representative for availability and information on this service. Refer to Maintenance Manual (P-764327-734) for further details on these procedures.
Page 18
We have more than 5,000 customers who are benefiting from STERIS maintenance agreements. Why not join them? Obtain complete details by calling 1-800-333-8828, or...
Need help?
Do you have a question about the AMSCO RELIANCE 430 and is the answer not in the manual?
Questions and answers