Replacement Packaged Terminal Air-Conditioning / Heat Pump • Installation, Operation, and Maintenance Manual • Read This First (continued) General precautions Recognize this symbol as an indication DANGER of important safety information. Electrical Supply Carefully read the rating plate located on the front panel. Th e RetroAire replacement PTAC/PTHP must: Inspection Be properly connected...
• Installation, Operation, and Maintenance Manual • General Product Information Controls Product description • Unit-mounted operating controls include thermostat, fan speed control, RetroAire Replacement Packaged Terminal Air Condition/Heat heat/cool switch, fan cycle switch, fresh air switch (if equipped) Pumps units are available in straight cooling (PTAC) or as heat pump •...
Replacement Packaged Terminal Air-Conditioning / Heat Pump • Installation, Operation, and Maintenance Manual • Features • Th is keeps the base pan free of condensate water, which could Indoor coil freeze protection (standard) otherwise freeze during colder outdoor temperatures. Th is feature will prevent the indoor coil from freeze up in the cooling mode.
Replacement Packaged Terminal Air-Conditioning / Heat Pump • Installation, Operation, and Maintenance Manual • Features Heat pump Optional wall-mounted thermostats Heat pump units are “Limited Range” and should be equipped with Thermostats available from EMI back-up electric resistance or hydronic heat. Limited Range heat pumps are designed to operate when outdoor temperatures are EMI off ers a thermostat that is compatible with your PTAC/PTHP between 75°F(24°C) and 40°F(4.4°C) and with a maximum indoor...
Replacement Packaged Terminal Air-Conditioning / Heat Pump • Installation, Operation, and Maintenance Manual • Sequence of Operation Trouble The following Sequence of Operation Code Status applies to PTAC/PTHP units. (Blinks) Th e R_ _C units are straight cool, single stage air conditioners avail- Normal Operation able with electric or hydronic heat.
Page 10
Replacement Packaged Terminal Air-Conditioning / Heat Pump • Installation, Operation, and Maintenance Manual • Sequence of Operation (continued) NOTE: with auxiliary heat will continue until the outdoor coil sensor reaches 50 ºF (10 ºC). • Remote-Mount Cooling Operation depends on the features of the wall-mounted thermostat.
Page 11
Replacement Packaged Terminal Air-Conditioning / Heat Pump • Installation, Operation, and Maintenance Manual • Performance Data Table 1 R25 performance data Model Cooling Sensible Heat Pump Indoor Air Fresh Air Inlet Shipping Heat Flow Flow Weight Ratio Btuh (kW) Btuh (kW) CFM (L/s) CFM (L/s) lbs (Kg)
Page 12
Replacement Packaged Terminal Air-Conditioning / Heat Pump • Installation, Operation, and Maintenance Manual • Electrical Specifi cations R25 - 9,000 BTU Table 2 electrical specifi cations Power Supply Compressor Fan Motor Electric Heat Unit Electrical Ratings Volt — 1–60 Volt Htr # Volt MOCP...
Page 13
Replacement Packaged Terminal Air-Conditioning / Heat Pump • Installation, Operation, and Maintenance Manual • Electrical Specifi cations (continued) R25 - 15,000 BTU Table 4 electrical specifi cations Power Supply Compressor Fan Motor Electric Heat Unit Electrical Ratings Volt — 1–60 Volt Htr # Volt...
Page 14
Replacement Packaged Terminal Air-Conditioning / Heat Pump • Installation, Operation, and Maintenance Manual • Notes The Right Fit for Comfort P/N 240007817, Rev. B [3/19/2010]...
Page 15
Replacement Packaged Terminal Air-Conditioning / Heat Pump • Installation, Operation, and Maintenance Manual • Notes P/N 240007817, Rev. B [3/19/2010] Made in USA...
Page 16
Warranty ECR International Inc 2201 Dwyer Avenue Utica, NY 13501 e-mail: info@RetroAire.com An ISO 9001-2000 Certified Company The Right Fit for Comfort 240007817, Rev. B [3/19/2010]...