Retro Aire RC55 Installation, Operation & Maintenance Manual

Packaged terminal air conditioner

Advertisement

Quick Links

RC55 PACKAGED TERMINAL AIR CONDITIONER
Replacement For Remington Series
STRAIGHT COOL ONLY
Nominal Capacities:
9,000 - 12,000 Btuh
Enviromaster International LLC
5780 Success Dr.
Rome, NY 13440
www.retroaire.com
RC55
CC55
An ISO 9001-2000 Certifi ed Company
P/N# 240002990, Rev. 1.4 [08/05]

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RC55 and is the answer not in the manual?

Questions and answers

Summary of Contents for Retro Aire RC55

  • Page 1 RC55 PACKAGED TERMINAL AIR CONDITIONER Replacement For Remington Series STRAIGHT COOL ONLY Nominal Capacities: 9,000 - 12,000 Btuh RC55 CC55 Enviromaster International LLC An ISO 9001-2000 Certifi ed Company 5780 Success Dr. Rome, NY 13440 P/N# 240002990, Rev. 1.4 [08/05]...
  • Page 2: To The Installer And Safety Instructions

    Visit our website www. Do not use the RetroAire RC55 PTAC if it has retroaire.com for a local representative listing. For damaged wiring, is not working properly, or has further assistance call 1-800-228-9364.
  • Page 3: Table Of Contents

    Warnings and Installer Responsibilities ....3 DANGER Controls and Components ........4 Product Description, Capacities, Air System ..4 Tampering with the RetroAire RC55 PTAC is dan- Heat-exchanger, Refrigeration, Electrical Wiring 4 gerous and may result in serious injury or death. Installation Instructions ........5-6 Tampering voids all warranties.
  • Page 4: Controls And Components

    PREPARATION FOR INSTALLATION PRODUCT DESCRIPTION The RetroAire RC55 replacement chassis is a con- 1. Remove the old unit from the wall sleeve and dispose of properly. ditioner designed to allow owners of Remington units to upgrade the performance of their room conditioning and achieve current effi...
  • Page 5: Installation Instructions

    INSTALLATION INSTRUCTIONS RC55 INSTALLATION KIT IMPORTANT: The correct condenser air baffl es The correct condenser air baffl es must be installed or performances may be im- stalled or performances may be im- • 1 Installation Manual • 1/2” x 1/2” Open-cell Foam Tape •...
  • Page 6: Final Inspection And Startup

    INSTALLATION INSTRUCTIONS Continued 8. Plug line cords into receptacles. • Install on the middle of the evaporator coil by pressing the round part of the clips through Note: Check rating plate voltage and amperage/fuse the coil fi ns. size for proper supply. •...
  • Page 7: Sequence Of Operation

    SEQUENCE OF OPERATION UNIT MOUNTED AND REMOTE THERMOSTAT Figure A CONTROLS: RetroAire units can be equipped with unit System System mounted or remote controlled thermostats. Turning the Switch unit mounted thermostat knob to the far left will produce the warmest room temperature while turning it all the Speed Speed Switch...
  • Page 8 SEQUENCE OF OPERATION Continued A. Place system switch in the “HEAT” position. CONDENSATE REMOVAL: The Dual Motor PTAC has a drain connection at each end of the condensate drain pan. B. Turn thermostat knob counter-clockwise. Motor- This allows the condensate to drain through the bulkhead ized valve should open and allow hot water to run to the area near the condenser fan.
  • Page 9: Cleaning And Maintenance

    CLEANING AND MAINTENANCE DANGER 9. Check weep holes along the rear fl ange of the base Before servicing the RetroAire Dual Motor PTAC, be pan, making sure they are open. sure to turn off electrical power to the unit. Failure to do so can result in a fi...
  • Page 10: Specifi Cations And Dimensions

    DIMENSIONS AND SPECIFICATIONS Note: Due to ongoing development programs, design and specifi cations may change without notice. CC55 CONTROL BOX CC55 CONTROL BOX CONDITIONED AIR T’STAT BLUB T’STAT BLUB LOCATION LOCATION OF 1/2” X 1/2” OF 1/2” X 1/2” OF 1/2” X 1/2” EVAPORATOR EVAPORATOR OPEN CELL...
  • Page 11: Warranty

    ALL PRODUCT LIMITED WARRANTY Enviromaster International LLC (EMI) warrants to the purchaser/owner that EMI products will be free from defects in material and workmanship under the normal use and maintenance for a period of twelve months for all components and sixty months on unit compressors from date of the original installation, or fi...

Table of Contents