Rc/rh22 packaged terminal rc/rh22 packaged terminal
air conditioner/heat pump
for new construction or as a
replacement for icecap rsk & islandaire ez-rk series (14 pages)
Single package vertical air conditioner/heat pump (40 pages)
Summary of Contents for Retro Aire RC15
Page 1
RC15 PACKAGED TERMINAL AIR CONDITIONER REPLACEMENT FOR: American Standard Series 41, American Air Filter Series 25 & Others STRAIGHT COOL Nominal Capacities: 9,000 - 12,000 - 15,000 & 18,000 Btuh BC15 RC15 CC15 Enviromaster International LLC An ISO 9001-2000 Certified Company 5780 Success Dr.
Do not use the RetroAire RC15 PTAC if it has dam- aged wiring, is not working properly, or has been To obtain technical service or warranty assistance damaged or dropped.
MUST BE REPLACED WITH A NEW CORD FROM THE MANUFACTURER, AND NOT REPAIRED. A rating plate identifying this RetroAire RC15 PTAC can be found on the unit. When referring to your unit, always have Each power cord should be checked before every use.
STANDARD FEATURES AND ACCESSORIES a washable, permanent filter makes service a snap. The 20 • The RC15 units are designed to fit both the existing gauge G-90U, galvanized steel construction of the chassis wall sleeve and cabinet of the old unit, but when ei- ensures long service life.
INSTALLATION INSTRUCTIONS RC15 INSTALLATION KIT IMPORTANT: The correct condenser air baffles must be • 1 Installation Manual • 1” x 1” Open-cell Foam Tape installed or performances may be impaired and/or the • 1 Condenser Baffle • 2 Condensor Baffles warranty will be voided.
INSTALLATION INSTRUCTIONS Continued 7. Ensure proper foam tape gaskets are used [Figure3]. Note: Check rating plate voltage and amperage/fuse size for proper supply. 8. Install cooling chassis by sliding it into the wall sleeve, 12. To install thermostat bulb to coil. once in place;...
FINAL INSPECTION AND STARTUP CAUTION The position of curtains or drapes over supply air grille may cause air to recirculate without cooling the room. The When the unit is first powered up, high humidity unit will short cycle and may cause premature compressor conditions can cause condensation to form on the failure.
SEQUENCE OF OPERATION Figure A UNIT MOUNTED AND REMOTE THERMOSTAT CONTROLS: RetroAire units can be equipped with unit SYSTEM SPEED SWITCH mounted or remote controlled thermostats. Turning the SWITCH unit mounted thermostat knob to the far left will produce the warmest room temperature while turning it all the way to the right will produce the coolest.
Page 9
SEQUENCE OF OPERATION Continued FAN CYCLE SWITCH: This option allows the operator of A. Place system switch in the “HEAT” position. the Dual Motor PTAC to have the evaporator fan cycle or run continuously. With the switch in the cycling position the B.
CLEANING AND MAINTENANCE DANGER 9. Check weep holes along the rear flange of the base pan, making sure they are open. Before servicing the RetroAire Dual Motor PTAC, be sure to turn off electrical power to the unit. Failure to 10.
RC15 SPECIFICATIONS AND DIMENSIONS IMPORTANT: Due to RetroAire’s on going development programs, designs and specifications may change without notice. Please consult factory for the latest information and submittal data before making any job site updates. Dimensions RC15 HYDRONIC HEAT Performance 104-156 (Single Row Coil) ”...
ALL PRODUCT LIMITED WARRANTY Enviromaster International Corporation LLC (EMI) warrants to the purchaser/owner, that the EMI products will be free from defects in material and workmanship under the normal use and maintenance for a period of twelve months for all components, and (60) months on unit compressors from date of the original installation or 15 months for all components and 63 months on unit compressors from the date of original sale whichever comes first.