Page 1
HS300 Operation Manual Contents subject to change without notice Version 2.1 2012-01-10...
Page 2
Declarations of compliance Wa r n i n g s Electrical installation United States For your protection, all mains (110V or 230V) equipment used This equipment has been tested and found to comply with the limits for a Class A where damp or wet conditions may occur, must be supplied from a digital device, pursuant to Part 15 of the FCC Rules.
140 Indicator Operation Manual Thank you for purchasing the 140 indicator. Please read all operating CONTENT instructions carefully before use and keep the following points in mind: * Avoid lengthy exposure to extreme heat or cold, your scale works best when operated at normal room temperature.
·OPERATION INTERFACE: Ⅱ KEY FUNCTION: 1. Display: 0.65” (17mm) 7-segment LCD, 5 digits FACEPLATE: 2. Keyboard: 4-key push button ·POWER: 1. Alkaline Batteries: 4 x “AAA” size cells When all displayed segments of LCD flashed, this indicates the batteries are low below 4.9V and you’d better to replace batteries;...
Page 5
HOLD UNIT PRINT Choose weighing units among kg-lb-lb: oz Hold these two buttons to show firmware version; A/D code or input Note: The weighing units that can be used are restricted by display working voltage of indicator. division, and calibration weight unit (restricted by P8, P9, and P10): UNIT For example, if the calibration unit is “kg”;...
TARE to confirm and go to next step, or press ON/OFF/ZERO to exit the Choose the weight inner code or input working voltage to be calibration mode. displayed. The working voltage range is 4.8V-8V. If the voltage The 140 indicator will display “CAP.--”, that means the following data is the is not within range, it may damage the indicator.
Page 7
can press ON/OFF/ZERO to exit the calibration mode. Or load 5%-100%FS try to repeat from step 5. The scale will return to normal weighing mode. weight, and use PRINT/HOLD and UNIT keys to input the loaded weight. Attention: To ensure the accuracy of the scale, it is recommended to use over If the input data is larger than 199999, it will show as “Hxxx”...
Page 8
Below is the drawing of position of the zero-point potentiometer on PCB for 3) P : Item AB parameters and one digit can be input AB.C conference, decrease ADC data by rotating clockwise, and increase ADC data 4) P : Item AB parameters and two digits can be input AB.CD by rotating counter-clockwise.
Page 9
as follows: calibration resolution calibration resolution <LF><Gross: reading, minus, decimal point, unit><CR><EXT> 7500 <LF> <Tare: reading, decimal point, unit><CR><EXT> 8000 <LF> <Net: reading, minus, decimal point, unit><CR><EXT> 10000 The number of position used: weight reading ---7; 12000 Minus ---1; 1000 15000 Decimal point ---1;...
Page 10
Calibration Display division value in different weight unit that can be used 0.2 lb 0.1 kg 0.2 lb 5 oz division value 2 lb 1 kg 2 lb Not available Lb:oz (oz) 20 lb 10 kg 20 lb Not available 0.0001kg 0.0001kg 0.0002lb...
Page 11
x = 5 : Power-on zero-point ±10%FS; x = 8 : +5d x = 6 : Power-on zero-point ±20%FS; Choose the zero tracking range as per the stability of weighing system, x = 7 : No limitation accuracy and weight excursion. The normal setting is +0.5d ~ +1.5d. 5.17) P17.x: Data filter intensity x = 8 : Power-on zero-point +1%FS x = 0 very weak...
Page 12
Ⅵ. The detail about RS232: weight. Minus sign follows after the first digit. c) Useless leading zero before digits is suppressed. 1. RS-232 connects between scale and Host: 2.3) Key to symbols used Scale -----------------------Cable---------------------------Host <LF> Line Feed character (hex 0AH) (DB9 female)--------(DB9 male)----(DB9 female)--------(DB9 male) <CR>...
Page 13
(4) Command: T<CR> (54h 0dh) Ⅶ. Relationship of capacity and the setting of P7, P8 and P9: Response: TARE function is activated, and then returns scale status. just like Table6: (Capacity unit is kg or lb) pressing TARE button: Resolution Division set by P8 and P9(P8=0)...
Page 14
Table7: (Capacity unit is kg or lb) Table8: (Capacity unit is kg or lb) Resolution Resolution Division set by P8 and P9(P8=1) Division set by P8 and P9(P8=2) set by P7 set by P7 0.0002 0.002 0.02 0.0005 0.005 0.05 0.1000 1.000 10.00...
Ⅹ Ⅷ. The meaning of some displayed symbols: .Key Definition summary: 1. 0¯ ¯ ¯ ¯ zero point is over the setting range ---------- MODE DEFINITION 2. 0 zero is below the setting range _ _ _ _ ---------- Enter or exit HOLD mode; output the 3.
ON/OFF/ P6.x 0, 1, 2 RS232 format: 0=8N1, 1=7O1, 2=7E1 ZERO Normal weighing mode Enter setup mode when sealed Resolution select: 500,600,750,800, (more than 3s) calibration switch is on? 1000,1200, 1500,2000,2400,2500, 3000, UNIT 3500, 4000, 5000, 6000, 7000, 7500, P7.xy 00-31 ON/OFF/ 8000, 10000, 12000, 15000, 20000,...
Page 17
11=Power-on zero-point +4%FS 12=Power-on zero-point +5%FS 13=Power-on zero-point +10%FS 14=Power-on zero-point +20%FS Weight signal within power-on zero point range, Choose which data as P14.x 0, 1, 2 current power-on zero point; 0= current weight ; 1= calibration zero-point; 2=switch-off zero-point Weight signal not within power-on zero point range, Choose which data as current power-on zero point;...
Page 18
UK and Europe Brecknell Foundry Lane Smethwick West Midlands B66 2LP Tel: +44 (0) 845 246 6717 Fa x : +44 (0) 845 246 6718 Email: sales@brecknellscales.co.uk Web site: www.brecknellscales.co.uk Brecknell 1000 Armstrong Drive Fairmont,MN 56031 Toll Free: 800-637-0529 Tel: 507-238-8702 Fax: 507-238-8271 Email: sales@brecknellscales.com...
Need help?
Do you have a question about the HS300 and is the answer not in the manual?
Questions and answers