Appendix; Failure Monitoring; Troubleshooting - WEST PAM-190-P Series Technical Documentation Manual

Amplifier plug for proportional valves
Table of Contents

Advertisement

6 Appendix

6.1 Failure monitoring

Following possible error sources are monitored continuously:
Source
Command signal PIN 2 / 4
LIM command
Command signal PIN 2 / 4
4... 20 mA
Solenoids output
EEPROM
(when switching on)

6.2 Troubleshooting

It is assumed that the device is in an operable state and there is communication between the module and the
WPC-300. Furthermore, the valve control parameterization has been set with the assistance of the valve data
sheets.
The RC in monitor mode can be used to analyze faults.
CAUTION: All safety aspects must be thoroughly checked when working with the RC (Remote
Control) mode. In this mode the module is controlled directly and the machine control cannot
influence the module.
FAULT
READY LED is off.
READY LED is flashing.
Page 23 of 24
Fault
Out of range
Out of range or broken wire
Wrong cabling, broken wire
Data error
CAUSE / SOLUTION
Presumably no power supply is present.
If there is no power supply there is also no communication via our operating pro-
gram. If a connection has been made to the WPC-300, then a power supply is also
available.
The flashing READY LED signals that a fault is detected by the equipment. The fault
could be:
Solenoid error or no signal at the input, if 4... 20 mA signals
LIM monitored input signals are parameterized.
Internal data error: press the command/SAVE button to delete the data error. The
system reloads the DEFAULT data.
With the WPC-300 operating program and ULA-310 the fault can be localized directly
via the monitor.
PAM-190-P-A/I
Characteristic
The output will be switched off and
the READY LED flashes.
The output will be switched off and
the READY LED flashes.
The output will be switched off and
the READY LED flashes.
The output will be switched off and
the READY LED flashes.The mod-
ule can only be activated by saving
the parameters again!
05.06.2020

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pam-190-p-aPam-190-p-iPam-190-p-io

Table of Contents