Sharp R-967 Service Manual page 30

Microwave oven grill and convection
Table of Contents

Advertisement

Pin No.
Signal
24
CNVSS
25
RESET
26
P41
IN/OUT
27
P40
OUT
28
XIN
29
XOUT
OUT
30
VSS
31
P27
OUT
32
P26
OUT
33
P25
OUT
34
P24
OUT
35
P23
OUT
36
P22
OUT
37
P21
OUT
38
P20
OUT
DESCRIPTION OF LSI
I/O
IN
Connected to VC.
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is applied. Temporarily
set to "L" level the moment power is applied, at this time the LSI is reset. Thereafter
set at "H" level.
Memory (EEPROM) data input/output.
Memory (EEPROM) clock out.
IN
Internal clock oscillation frequency input setting.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit
with respect to XIN terminal.
Internal clock oscillation frequency control output.
Output to control oscillation input of XOUT.
IN
Power source voltage: -5V.
VC voltage of power source circuit input.
Grill (TOP) heating element driving signal.
To turn on and off the grill heating
element relay (RY3). "L" level during
grill cooking, convection cooking or
dual cooking, "H" level otherwise.
The heater relay turns on and off
within a 48 second time base in
accordance with the special program
in LSI.
Convection heating element driving signal.
To turn on and off the relay (RY4). "L"
level during grill cooking, convection
cooking or dual cooking, "H" level
otherwise.
The heater relay turns on and off within
a 48 second time base in accordance
with the special program in LSI.
Oven lamp and turntable motor driving signal(Square Waveform : 50Hz).
To turn on and off shut-off relay (RY1). The
square waveform voltage is delivered to the
relay (RY1) driving circuit.
Convection motor driving signal.
To turn on and off shut-off relay(RY7). "L"
level during convection or dual cooking "H"
level otherwise. (Relay RY7 does not turn on
at preheating mode.)
Fan motor driving signal.
To turn on and off the fan motor relay RY6. "L"
level during cooking, or for 5 minutes after grill
cooking or for a while after convection or dual
cooking. "H" level otherwise.
Terminal not used.
Damper motor relay driving signal.
To turn on and off shut-off relay (RY8).
Touch control transformer driving signal.
To turn on and off the shut off relay (RY5). If the oven has not been used for more
than 2 minutes, the relay RY5 will be turned off. The relay RY5 will be turned on
when the oven door is opened and closed.
Description
24
Power output
ON time
100 %
48 sec.
90 %
44 sec.
80 %
40 sec.
70 %
36 sec.
60 %
32 sec.
50 %
26 sec.
40 %
22 sec.
30 %
16 sec.
20 %
12 sec.
10 %
8 sec.
Power output
ON time
100 %
48 sec.
90 %
44 sec.
80 %
40 sec.
70 %
36 sec.
60 %
32 sec.
50 %
26 sec.
40 %
22 sec.
30 %
16 sec.
20 %
12 sec.
10 %
8 sec.
20 msec.
During cooking
During
OFF
cooking
(Convection or dual cooking)
ON
H.
OFF
ON
L
During cooking or for awhile after
grill convection or dual.
OFF
ON
OFF time
0 sec.
4 sec.
8 sec.
12 sec.
16 sec.
22 sec.
26 sec.
32 sec.
36 sec.
40 sec.
OFF time
0 sec.
4 sec.
8 sec.
12 sec.
16 sec.
22 sec.
26 sec.
32 sec.
36 sec.
40 sec.
H
L
H.
GND
L
GND
H.
GND
L