Problem
White powder residue
forming within burner
box or on adjacent walls
or furniture.
Heater produces un-
wanted odors.
Heater shuts off in use
(ODS operates).
Gas odor exists even
when control knob is in
OFF position.
Moisture/condensation
noticed on windows.
Purchase these heater accessories from your local dealer. If they can not supply these acces-
sories, contact ProCom Heating, Inc. at 1-866-573-0674 for information.
EQUIPMENT SHUTOFF VALVE
For all models. Equipment shutoff
valve with 1/8" NPT tap.
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply might be low (propane/LP units only)
You may feel your gas pressure is too low. If so, contact your local gas supplier.
You may have further questions about installation, operation, or troubleshooting. If so, contact
ProCom Heating, Inc. at 1-866-573-0674.
When calling, please have your model and serial numbers of your heater ready.
200124-01D
TROUBLESHOOTING
Possible Cause
1. When heated, the vapors
from furniture polish, wax,
carpet cleaners, etc., turn
into white powder residue.
1. Heater is burning vapors from
paint, hair spray, glues, etc. See
IMPORTANT statement, page 22.
2. Gas leak. See Warning State-
ment at the top of page 22.
3 Low fuel supply.
1. Not enough fresh air is avail-
able.
2. Low line pressure.
3. O D S / p i l o t i s p a r t i a l l y
clogged.
1. Gas leak. See Warning
Statement at top of page 22.
2. Control valve is defective.
1. Not enough combustion/
ventilation air.

ACCESSORIES

SERVICE HINTS

When Gas Pressure Is Too Low

TECHNICAL SERVICE

www.usaprocom.com
Corrective Action
1. Turn heater off when using
furniture polish, wax, carpet
cleaner or similar products.
1. Ventilate room. Stop using
odor causing products while
heater is running.
2. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 14).
3. Refill supply tank (Propane/
LP models).
1. Open window and/or door for
ventilation.
2. Contact local gas supplier.
3. Clean ODS/pilot (see Care
and Maintenance, page 20).
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 14).
2. Replace control valve.
1. Refer to Air for Combus-
tion and Ventilation require-
ments, page 7.
25