This appliance is factory
preset for propane/LP gas.
No changes are required for
connecting to propane/LP.
Only a qualified installer or service
technician can perform gas selec-
tion and connecting to gas supply.
CAUTION: Two gas line in-
stallations at the same time are
prohibited.
CAUTION: To avoid gas leak-
age for the gas not being used at
the inlet of regulator, a qualified
installer or service technician
must use supplied cap.
You will notice a color coded
plunger on the inside of the regu-
lator. This is normal. When the in-
let connection fitting is inserted
and tightened, this plunger will
be pushed back by the fitting
making all of the adjustments
for the gas being supplied. DO
NOT REMOVE THE PLUNGER.
The regulator will not work.
The inlet regulator is color coded
for identification of the correct
gas type. Blue is for propane (LP
gas) and yellow is for natural gas.
10
INSTALLATION
GAS SELECTION
Gas Connection
Yellow Natural Gas
Plunger Underneath
Metal Cap
Insert Gas Fitting
for Natural Gas
1. Remove blue dust cover.
Blue Dust Cover
www.usaprocom.com
Natural Gas
Shown
NG
LP
3-3.5" WC
8-11" WC
WARNING:
Make sure Regulator Cap is in the appropriate position
ADVERTENCIA:
Asegúrese la tapa del regulador esté en la posición adecuada,
Correct Pilot Flame Pattern
as shown in diagrams. Installation and service should be done by
como se muestra en los diagramas. La instalación y reparaciones deben ser realizadas
qualified service technician only.
por un técnico de servicio calificado solamente.
Natural Gas
Gas Natural
Natural Gas
Shown
When using natural gas:
Cuando se utiliza gas natural:
3-3.5" WC
NG
8-11" WC
LP
Make sure the cap is installed in the propane/LP inlet of regulator.
Asegúrese de que la tapa está instalado en el propano/LP entrada del regulador.
Use thread sealant to assure there are no leaks.
Utilice sellador de roscas para asegurar que no haya fugas.
Propane/LP Gas
Propano/LP Gas
Incorrect Pilot Flame Pattern
When using propane/LP gas:
Cuando se utiliza el gas propano / LP:
Make sure the cap is installed in the natural gas (NG) inlet of regulator.
Asegúrese de que la tapa está instalado en la entrada de gas natural (GN) del regulador.
Use thread sealant to assure there are no leaks.
Utilice sellador de roscas para asegurar que no haya fugas.
1/2 Glass
Height
Correct Burner Flame Pattern
Yellow
Tipping
1/2 Glass
Height
Incorrect Burner Flame Pattern
LP
NG
Blue Plunger
Yellow Plunger
WARNING: Make sure the supplied cap is
FOR PROPANE GAS SUPPLY
This appliance may be installed in an aftermarket,*
PARA LA FUENTE DE GAS DEL PROPANE
permanently located, manufactured (mobile) home, where
installed in unused regulator fitting before
not prohibited by local codes.
connecting the correct gas supply line.
CAUTION: The heater requires an external regulator to reduce
This appliance is only for use with propane or natural gas.
the LP tank pressure to a maximum of 14" W.C. Never connect
WARNING: Do not use natural gas and
Field conversion by any other means including the use of
this product directly to the supply tank.
propane gas together.
PRECAUCIÓN: El calentador requieres una externa regulador
a kit is not permitted.
INSTALL SUPPLIED CAP IN FITTING
CAUTION: Two gas line installations at
para reducir la presión del tanque de gas a un máximo de 14"
Procom Heating, Inc. U.S. Patent Information
W.C. Nunca conecte este producto directamente al tanque de
NOT BEING USED.
the same time are prohibited.
This product may be covered by one or more of the following
suministro.
INSTALAR TAPA SUMINISTRADA MONTAJE NO SE UTILIZA.
ADVERTENCIA: Asegúrese de que la línea
FOR NATURAL GAS SUPPLY
8,915,239 8,851,065 8,764,436 8,757,202 8,757,139 8,752,541
8,568,136 8,545,216 8,517,718 8,516,878 8,506,290 8,465,277
Gas Inlet / Gas esté
PARA LA FUENTE DE GAS DEL NATURAL
no utilizado se conecta por primera vez
8,317,511 8,297,968 8,281,781 8,241,034 8,235,708 8,152,515
NOTICE: An additional gas regulator will be necessary if the
antes de conectar la línea de suministro
8,011,920 7,967,006 7,967,007 7,654,820 7,730,765 7,677,236
INLET GAS PRESSURE MAX 1/2 PSIG (3.5 KPa)
local natural gas pressure exceeds the heater's rated maximum
de gas correcta.
inlet pressure. If in doubt, contact the local gas utility. If natural
ADVERTENCIA: No utilice el gas natural y
gas inlet pressure exceeds 10" W.C., the safety pressure switch
will activate. See owners manual for proper procedure to bypass
TOLL-FREE Customer Care Number: 1-866-573-0674
el gas propano juntos.
the pressure switch.
Numero de Atención al Cliente GRATUITO: 1-866-573-0674
PRECAUCIÓN: Dos instalaciones de
Visit our website for more information www.usaprocom.com
AVISO: Un regulador de gas adicional será necesario si la
líneas de gas al mismo tiempo están
Visite nuestra página web para más informacion www.usaprocom.com
presión del gas natural local excede de entrada nominal máxima
prohibidos.
del calentador presión. En caso de duda, póngase en contacto
con la compañía de gas local. Si la presión de entrada de gas
natural supera los 10" WC, el interruptor de presión de
200110-01B
seguridad se activará. Consulte el manual del propietario para el
03/15
procedimiento adecuado de derivación el interruptor de presión.
Figure 7 - Back of Stove
Blue Propane/LP Gas
Plunger Underneath
Dust Cover
Insert Gas Fitting
for Propane/LP Gas
Figure 8 - Gas Regulator
FOR PROPANE/LP GAS
INSTALLATION: BLUE
DO NOT REMOVE
Blue Propane/LP
Install Gas Fitting Here
United States patents:
7,607,426 7,434,447
Other patents pending.
Plunger
200124-01D