If you use the device under UL 61010-2-201 conditions you must also keep to the following
safety notices in addition to the general safety notices for protection against explosion:
NOTICE
Suitable fusing for the power supply cable
The current at the connecting terminals must not exceed 3 A. Use a fuse for the power supply
that protects against currents > 3 A.
• In areas where NEC or CEC are used, the following requirements must be met:
• In other areas, the following requirements must be met:
You do not need a fuse for the power supply cable if you use a voltage source according LPS or
NEC Class 2.
NOTICE
Protective ground
A PELV circuit contains a connection to protective ground. Without a connection to protective
ground, or in case there is a fault in the connection to the protective ground, the voltage for the
circuit is not stabilized (limited).
NOTICE
The "Limited Energy" circuit and other circuits must be separated by at least basic insulation.
Grounding
Danger to life from overvoltage, fire hazard
When using outdoor antennas, the shared or grounded pin of the circuit must be connected to
the shield of the coaxial cable and to all touchable conductive parts and circuits. Otherwise,
there may be impermissibly high voltages on touchable parts in the event of a fault.
SCALANCE WxM766
Operating Instructions, 07/2021, C79000-G8976-C617-02
– Suitable for DC (min. 60 V / max. 3 A)
– Breaking current min. 10 kA
– UL/CSA listet (UL 248‑14 / CSA 22.2 No. 248.14)
– Classes R, J, L, T or CC
– Suitable for DC (min. 60 V / max. 3 A)
– Breaking current min. 10 kA
– Permitted for electric circuits according to IEC / EN 60947‑1/2/3
– Breaking characteristics: B or C for circuit-breakers or fuses
WARNING
Connection
47