Viking 300-IP Product Manual page 9

Ip paging horn for sip endpoint paging or multicast paging / background music
Table of Contents

Advertisement

D. Manually Resetting the Security Code to Enter Programming
Note: This procedure will not erase a username and password used to access the 300-IP program mode. Only the security code is set to default.
Step 1.
Power down the 300-IP speaker by disconnecting the LAN Cable (RJ45 plug).
Step 2.
Provide a short across the Reset wires, then reconnect the LAN Cable (RJ45 plug).
Keep the short across the Reset wires until you hear a single beep, silence and then 2 beeps (approximately 11 seconds). Then
Step 3.
remove the short across the Reset wires. The Status LED will remain off for 5 seconds, light steady for 3 seconds, flash slowly for 3
seconds then fast flash, (after the 2 beeps), indicating when to remove the short across the Reset wires.
Step 4.
The security code is now reset to 845464 (factory default).
Step 5.
You can now enter programming by following the steps in section A.
E. Manually Resetting All Network Parameters to Factory Default
Note: This procedure will erase a username and password that are used to access the 300-IP program mode.
Step 1. Power down the 300-IP speaker by disconnecting the LAN Cable (RJ45 plug).
Step 2. Provide a short across the Reset wires, then reconnect the LAN Cable (RJ45 plug).
Keep the short across the Reset wires until you hear a single beep, silence and then 2 beeps (approximately 11 seconds). Continue
with the short across the Reset wires until you hear 4 more beeps (approximately 6 seconds later), then remove the short across the
Step 3.
Reset wires. The Status LED will remain off for 5 seconds, light steady for 3 seconds, flash slowly for 3 seconds (2 beeps) flash fast
for 6 seconds, (4 beeps), then light steady indicating when to remove the short across the Reset wires.
Step 4. You can now enter programming by following the steps in section A.
DESCRIPTION
Connect / Disconnect
VLAN Settings
Unit Name
SIP Server
Peer to Peer Settings
Outbound Proxy
Authentication ID
Register Fails (Re-Resolve or Alternate Server)
Security Code (factory set to 845464)
Access Code (1 - 6 digits, blank = Disabled, factory set to 123456)
Pre Page Tone
Multicast Page Type
SIP Page / Call Priority VS Multicast
Multicast Paging (Standard or Polycom, factory set to Standard)
Multicast Paging Volume (0 - 1 9, factory set to 1)
Night Ring Timed Operation
Time Zone Settings / Daylight Saving Time
External Relay (factory set to Disabled)
Ext Relay Mode
(Door Strike, Paging, Ring, Ring Flash, factory set to Door Strike)
Ext Relay Activation Command ( 1 or 2 digits, factory set to
Ext Relay Activation Time (0.5 - 99 seconds, factory set to 5 seconds)
Ext Relay Buzz Volume (1 - 3 or Disabled, factory set to 3)
Ext Relay Latch Commands
Programming Features Index
(Enabled or Disabled, factory set to Enabled) NOTE: Relay Mode must be set to Door Strike
) NOTE: Relay Mode must be set to Door Strike.
QQ
9
Section
Page
A
7
C
8
1
10
2
10
3
10
4
10
5
10
6
10
7
11
8
11
9
11
10
11
11
12
12
13
13
13
14
14
15
14
16
15
17
15
18
15
19
15
20
16
21
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

300-ip-ewp

Table of Contents