Troubleshooting - adept technology HM140/1 Installation Manual

Foil heating mat system
Table of Contents

Advertisement

6 Troubleshooting

Symptom
Floor doesn't heat
Floor warm all the time
Floor not warm enough
Installation instructions
not available
Probable Causes
No voltage.
Circuit breaker tripped.
Ground-fault tripped in
the thermostat.
Thermostat not turned
on.
Cable not connected to
Thermostat.
Floor temperature sensor
not connected.
Faulty sensor.
Clock not set correctly.
Thermostat setting not
set correctly.
12
Corrective Action
Check circuit breaker.
Ensure that there are not too many mats or other
appliances connected on the same circuit. The
Foil Heating Mat may require a dedicated circuit.
See the Product Selection Table of this manual.
Refer to Thermostat Installation and Operation
Manual.
Refer to Section 4 of this manual, and the
Thermostat Installation and Operation Manual.
Refer to Thermostat Installation and Operation
Manual.
Refer to Thermostat Installation and Operation
Manual.
Contact Adept at 01394 593110.
Refer to Thermostat Installation and Operation
Manual.
Refer to Thermostat Installation and Operation
Manual.
Contact Adept (Tel: 01394 593110)