ELECTRIC HEAT KITS EHS
3-6 Ton LIGHT CoMMERCIAL Roof ToP UnITS
ModELS: dRC, dRH, dBC
InSTALLATIon InSTRUCTIonS
Attention Installing Personnel
As a professional installer, you have an obligation to know the prod-
uct better than the customer. This includes all safety precautions
and related items.
Prior to actual installation, thoroughly familiarize yourself with this
Instruction Manual. Pay special attention to all safety warnings.
Often during installation or repair, it is possible to place yourself in a
position which is more hazardous than when the unit is in operation.
Remember, it is your responsibility to install the product safely and to
know it well enough to be able to instruct a customer in its safe use.
Safety is a matter of common sense...a matter of thinking before
acting. Most dealers have a list of specific good safety practices...
follow them.
The precautions listed in this Installation Manual are intended as
supplemental to existing practices. However, if there is a direct
conflict between existing practices and the content of this manual,
the precautions listed here take precedence.
Description
These installation instructions supplement the electric heater kits
for installation in the following models:
DRC036, DRC048, DRC060, DRC072
DRH036, DRH048, DRH060, DRH072
DBC036, DBC048, DBC060, DBC072
DBH036, DBH048, DBH060, DBH072
These instructions should be used only as a supplement to
installation instructions IOD-1032 for DRC and DRH models,
or IOD-1043 for DBC and DBH models.
O
NLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL
(
, "
REPAIR
HEREINAFTER
SERVICE
MANUAL SHOULD SERVICE THE EQUIPMENT
BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM
IMPROPER SERVICE OR SERVICE PROCEDURES
ASSUME RESPONSIBILITY FOR ANY INJURY OR PROPERTY DAMAGE WHICH MAY
. I
,
RESULT
N ADDITION
IN JURISDICTIONS THAT REQUIRE ONE OR MORE
LICENSES TO SERVICE THE EQUIPMENT SPECIFIED IN THIS MANUAL
LICENSED PERSONNEL SHOULD SERVICE THE EQUIPMENT
,
,
INSTALLATION
ADJUSTMENT
SERVICING OR REPAIR OF THE EQUIPMENT
,
SPECIFIED IN THIS MANUAL
OR ATTEMPTING TO INSTALL
REPAIR THE EQUIPMENT SPECIFIED IN THIS MANUAL WITHOUT PROPER
TRAINING MAY RESULT IN PRODUCT DAMAGE
.
INJURY OR DEATH
PROP 65 WARNING
FOR CALIFORNIA CONSUMERS
Cancer and Reproductive Harm -
www.P65Warnings.ca.gov
EHX
And
foR
dBH
And
,
ADJUST
")
THE EQUIPMENT SPECIFIED IN THIS
. T
HE MANUFACTURER WILL NOT
. I
F YOU SERVICE THIS UNIT
. I
MPROPER
,
ADJUST
,
PROPERTY DAMAGE
WARNING
© 2019
19001 Kermier Rd., Waller, TX 77484
www.daikincomfort.com
P/N: IOD-7100
HIGH VOLTAGE
D
ISCONNECT
THIS UNIT.
TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR
DEATH.
INSTRUCTIONS
1. Disconnect all power to the unit, both indoor and outdoor.
2. Remove control box door.
3. Remove blower door.
4. Locate heater box. Remove screws holding the heater box cover
in place (Figure 1).
BLOWER DOOR
CONTROL
BOX DOOR
,
SERVICE OR
,
YOU
,
ONLY
ELECTRIC
PANEL PART
,
SERVICE OR
,
PERSONAL
0140M00517-A
Date: November 2019
WARNING
!
ALL
POWER BEFORE SERVICING OR INSTALLING
M
ULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE
HEAT BOX
COVER
Figure 1
ELECTRIC HEATER KIT
Figure 2
Wires and some components are not shown
HORIZONTAL
SUPPLY COVER
HEATING
ELEMENT PART