Thetford Cassette C2 Repair Manual page 43

Hide thumbs Also See for Cassette C2:
Table of Contents

Advertisement

Remove the seal
D
from the control well.
Take the pump out of
the watertank.
Cut the cable just
E
above the pump with
the wire stripper.
Cut the white wire
insulation off so that
the blue and brown
wire stay intact.
Strip the blue and
F
brown wire with the
wire-stripper.
Place the shrink tube
on the wires from the
new pump.
Connect the wires to
G
each other (blue-
blue/brown-brown) with
the connector pliers.
Place the shrink
tube on the connector
pliers.
09/11/2006
Description: C402 C X
Pump
42